Bingyuan Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Bingyuan Lu has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Adrian Nightingale
Mechanical Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton SO17 1BJ, United Kingdom
1 shared publication- Huan Wang
Hua Zhong Univ Sci & Technol HUST, Wuhan, Hubei, Peoples R China
1 shared publication James Lunn
Mechanical Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton SO17 1BJ, United Kingdom
1 shared publicationKen Yeung
Mechanical Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton SO17 1BJ, United Kingdom
1 shared publicationLiam Carter
Mechanical Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton SO17 1BJ, United Kingdom
1 shared publication- Liz J. Shaw
University of Reading
1 shared publication
Latest Publications
- Open Access
- 31 January 2024
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 58 (6) , 2956-2965
Droplet Microfluidic-BasedIn SituAnalyzer for Monitoring Free Nitrate in Soil
Monitoring nutrients in the soil can provide valuable information for understanding their spatiotemporal variability and informing precise soil management. Here, we describe an autonomous in situ analyzer for the real-time monitoring of nitrate in soil. The analyzer can sample soil nitrate using either microdialysis or ultrafiltration probes placed within the soil and quantify soil nitrate using droplet microfluidics and colorimetric measurement. Compared with traditional manual sampling and lab analysis, the analyzer features low reagent consumption (96 μL per measurement), low maintenance requirement (monthly), and high measurement frequency (2 or 4 measurements per day), providing nondrifting lab-quality data with errors of less than 10% using a microdialysis probe and 2-3% for ultrafiltration. The analyzer was deployed at both the campus garden and forest for different periods of time, being able to capture changes in free nitrate levels in response to manual perturbation by the addition of nitrate standard solutions and natural perturbation by rainfall events.
- 31 January 2024
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 58 (6) , 2956-2965
Open AccessDroplet Microfluidic-BasedIn SituAnalyzer for Monitoring Free Nitrate in Soil
Monitoring nutrients in the soil can provide valuable information for understanding their spatiotemporal variability and informing precise soil management. Here, we describe an autonomous in situ analyzer for the real-time monitoring of nitrate in soil. The analyzer can sample soil nitrate using either microdialysis or ultrafiltration probes placed within the soil and quantify soil nitrate using droplet microfluidics and colorimetric measurement. Compared with traditional manual sampling and lab analysis, the analyzer features low reagent consumption (96 μL per measurement), low maintenance requirement (monthly), and high measurement frequency (2 or 4 measurements per day), providing nondrifting lab-quality data with errors of less than 10% using a microdialysis probe and 2-3% for ultrafiltration. The analyzer was deployed at both the campus garden and forest for different periods of time, being able to capture changes in free nitrate levels in response to manual perturbation by the addition of nitrate standard solutions and natural perturbation by rainfall events.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Calculation and analysis of the hot-spot temperature-rise for large power transformer based on 3D electromagnetic-fluid-thermal coupling method
The heating and cooling is very complex process for winding in large power transformer, which involves fluid dynamic, manufacture technology and numerical heat transfer and other related disciplines. Recently, the electromagnetic-Fluid-thermal coupled method and thermal network method are widely used by domestic and foreign researchers, whereas the oil flow distribution can not be taken into account using the two mentioned methods, thus the accuracy of the heat transfer properties will be affected. This paper presents a three-dimensional (3D) electromagnetic-fluid-thermal coupling approach to compute the hot-spot temperature-rise of winding area for large power transformer. An ODFS-400 MVA / 500 kV single-phase auto-transformer is used as the prototype model being studied and the 3D fine computation model of the winding area is established. To validate the correctness and applicability of the proposed method, the numerical results obtained from the proposed method are compared with those of experimental ones.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Calculation and analysis of the hot-spot temperature-rise for large power transformer based on 3D electromagnetic-fluid-thermal coupling method
The heating and cooling is very complex process for winding in large power transformer, which involves fluid dynamic, manufacture technology and numerical heat transfer and other related disciplines. Recently, the electromagnetic-Fluid-thermal coupled method and thermal network method are widely used by domestic and foreign researchers, whereas the oil flow distribution can not be taken into account using the two mentioned methods, thus the accuracy of the heat transfer properties will be affected. This paper presents a three-dimensional (3D) electromagnetic-fluid-thermal coupling approach to compute the hot-spot temperature-rise of winding area for large power transformer. An ODFS-400 MVA / 500 kV single-phase auto-transformer is used as the prototype model being studied and the 3D fine computation model of the winding area is established. To validate the correctness and applicability of the proposed method, the numerical results obtained from the proposed method are compared with those of experimental ones.