Mirella Da Re
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mirella Da Re has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Danilo Villalta
Immunology and Allergy, S. Maria degli Angeli Hospital, ASFO, Azienda Sanitaria Friuli Occidentale (ASFO), Pordenone, Italy
2 shared publications - Anna Moratto
Department of Immunology and Allergy, S. Maria degli Angeli Hospital, Pordenone, Italy
1 shared publication Francesca Grizzo
Immunology and Allergy Unit Santa Maria degli Angeli Hospital Pordenone Italy
1 shared publicationFrancesca Marinoni
PRIMA Lab SA Laboratories Balerna Switzerland
1 shared publication- Giacomo Malipiero
Personalized Medicine Asthma and Allergy, Humanitas Clinical and Research Center, IRCCS, Rozzano, 20089 Milan, Italy
1 shared publication - Giuseppe Parrinello
UOSD Allergologia e Immunologia Clinica, Dipartimento Scienze Mediche e Chirurgiche, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Roma, Italy
1 shared publication
Latest Publications
- Open Access
- 30 January 2024
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 38 (3) , e25003
Diagnostic accuracy of a novel point‐of‐care test for simultaneous detection of anti‐transglutaminase IgA and anti‐deamidated gliadin IgG antibodies
Background: Point‐of‐care tests (POCTs) may have a role in detecting undiagnosed cases of Celiac disease (CD). We assessed the diagnostic accuracy of a novel POCT, compared with the conventional serological methods, for simultaneous anti‐transglutaminase (tTG) IgA and anti‐deamidated gliadin (DGP) IgG antibody detection. Furthermore, we evaluated the effect of different biological matrices (whole blood and serum) on test performance.Methods: Serum and whole blood from celiac or suspected celiac patients who underwent duodenal biopsy were assayed for the presence of anti‐tTG IgA and anti‐DGP IgG both with the reference standard methods (Thermo Fisher Scientific, Uppsala, Sweden) and with the POCT (PRIMA Lab SA, Balerna, Switzerland).Results: 266 sera (101 negative and 165 positive) and 60 whole blood samples (34 positive and 26 negative) were included in the study. POCT for anti‐DGP IgG showed a sensitivity of 84.3% and a specificity of 90.1%, with positive (PPV) and negative predictive values (NPV) of 91.07% and 82.73%. POCT for anti‐tTG IgA showed a sensitivity of 98.31% and a specificity of 98.02%, with a PPV and NPV of 98.31% and 98.02%. Test accuracies were 86.94% and 98.17%, respectively. The agreement of the results between the two different matrices showed a strong correlation rate: 95% for anti‐DGP IgG and 100% for anti‐tTG IgA.Conclusion: The anti‐tTG IgA/anti‐DGP IgG‐based POCT showed good diagnostic accuracy with comparable sensitivities and specificities to reference standard methods in detecting CD in symptomatic patients and could be considered as a mass screening test before referring to conventional serology.
- 30 January 2024
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 38 (3) , e25003
Open AccessDiagnostic accuracy of a novel point‐of‐care test for simultaneous detection of anti‐transglutaminase IgA and anti‐deamidated gliadin IgG antibodies
Background: Point‐of‐care tests (POCTs) may have a role in detecting undiagnosed cases of Celiac disease (CD). We assessed the diagnostic accuracy of a novel POCT, compared with the conventional serological methods, for simultaneous anti‐transglutaminase (tTG) IgA and anti‐deamidated gliadin (DGP) IgG antibody detection. Furthermore, we evaluated the effect of different biological matrices (whole blood and serum) on test performance.Methods: Serum and whole blood from celiac or suspected celiac patients who underwent duodenal biopsy were assayed for the presence of anti‐tTG IgA and anti‐DGP IgG both with the reference standard methods (Thermo Fisher Scientific, Uppsala, Sweden) and with the POCT (PRIMA Lab SA, Balerna, Switzerland).Results: 266 sera (101 negative and 165 positive) and 60 whole blood samples (34 positive and 26 negative) were included in the study. POCT for anti‐DGP IgG showed a sensitivity of 84.3% and a specificity of 90.1%, with positive (PPV) and negative predictive values (NPV) of 91.07% and 82.73%. POCT for anti‐tTG IgA showed a sensitivity of 98.31% and a specificity of 98.02%, with a PPV and NPV of 98.31% and 98.02%. Test accuracies were 86.94% and 98.17%, respectively. The agreement of the results between the two different matrices showed a strong correlation rate: 95% for anti‐DGP IgG and 100% for anti‐tTG IgA.Conclusion: The anti‐tTG IgA/anti‐DGP IgG‐based POCT showed good diagnostic accuracy with comparable sensitivities and specificities to reference standard methods in detecting CD in symptomatic patients and could be considered as a mass screening test before referring to conventional serology.
- Open Access
- 1 January 2022
- Published by Annals of Laboratory Medicine in Annals of Laboratory Medicine
- Vol. 42 (1) , 113-116
New-Generation Quantitative Immunoassays for SARS-CoV-2 Antibody Detection: Need for Harmonization
Danilo Villalta, M.D., Anna Moratto, Ph.D., Valeria Salgarolo, Ph.D., Mirella Da Re, Ph.D., Roberto Giacomello, Ph.D., and Giacomo Malipiero, M.D.. Ann Lab Med 2022;42:113-6. https://doi.org/10.3343/alm.2022.42.1.113
- 1 January 2022
- Published by Annals of Laboratory Medicine in Annals of Laboratory Medicine
- Vol. 42 (1) , 113-116
Open AccessNew-Generation Quantitative Immunoassays for SARS-CoV-2 Antibody Detection: Need for Harmonization
Danilo Villalta, M.D., Anna Moratto, Ph.D., Valeria Salgarolo, Ph.D., Mirella Da Re, Ph.D., Roberto Giacomello, Ph.D., and Giacomo Malipiero, M.D.. Ann Lab Med 2022;42:113-6. https://doi.org/10.3343/alm.2022.42.1.113