Abdur-Rahman Siddiqui
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Abdur-Rahman Siddiqui has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Jeanne N'DIaye
University of Illinois Urbana-Champaign
5 shared publications - Joaquín Rodríguez-López
Department of Chemistry, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
5 shared publications - Jahan M. Dawlaty
University of Southern California
4 shared publications - Kristin Martin
Department of Chemistry
4 shared publications - Veronica Augustyn
Department of Materials Science and Engineering North Carolina State University Raleigh North Carolina USA
4 shared publications - Rohit Bhargava
University of Illinois Urbana-Champaign
3 shared publications
Latest Publications
- Open Access
- 4 November 2025
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 16 (48) , 23189-23202
Real-time monitoring of the reversible capture and release of CO 2 on anthraquinone and riboflavin-modified graphitic electrodes using ATR-SEIRAS
In situ ATR-SEIRAS was used to monitor the real-time functionalization and reversible capture and release of CO 2 at the electrode/electrolyte interface from anthraquinone and 10-ethyl-3-methyl flavin derivative-modified graphitic electrodes.
- 4 November 2025
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 16 (48) , 23189-23202
Open AccessReal-time monitoring of the reversible capture and release of CO 2 on anthraquinone and riboflavin-modified graphitic electrodes using ATR-SEIRAS
In situ ATR-SEIRAS was used to monitor the real-time functionalization and reversible capture and release of CO 2 at the electrode/electrolyte interface from anthraquinone and 10-ethyl-3-methyl flavin derivative-modified graphitic electrodes.
- Open Access
- 21 May 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Real-time Monitoring of the Reversible Capture and Release of CO2 on Anthraquinone and Riboflavin-Modified Graphitic Electrodes using ATR-SEIRAS
Electrochemically mediated carbon capture (EMCC) offers a promising alternative to thermochemical carbon capture methods due to its higher energy efficiency and the ability to operate under standard conditions. Graphitic electrodes functionalized with redox-active organic (RAO) capture agents offer a unique opportunity for an inexpensive, abundant, and easily scalable system for direct EMCC. However, the mechanistic understanding and observation of intermediate capture states on carbon surfaces using spectroscopic signatures remains unexplored. Herein, we present in situ monitoring of the reversible capture and release of carbon dioxide (CO2) from graphene-on-gold electrodes modified with grafted anthraquinone (AQ) and a synthesized riboflavin derivative, 10-ethyl-3-methyl flavin derivative (MFD). These electrodes conveniently enable the use of surface-enhanced infrared absorption spectroscopy in an attenuated total reflectance configuration (ATR-SEIRAS). We successfully decouple the spectral responses of the CO2 reduction reaction (CO2RR) and CO2 capture processes by characterizing AQ- and MFD-modified electrodes under argon and CO2 atmospheres. Continuous polarization of the electrode to generate the reduced forms of AQ also generates carbonate (CO32-) peaks at 1640 cm-1 and 1380 cm-1 that overshadow the spectral responses of AQ-bound CO2. Conversely, reducing AQ or MFD under inert atmosphere, followed by introducing CO2 with no applied potential (i.e. at open circuit) results in the growth of distinct spectral features ~1710-1630 cm-1. The release of CO2 was observed through the regeneration of an intense carbonyl stretch at ~1660 cm-1 upon electrooxidation, corresponding with CV observations for AQ and MFD. Preliminary CO2 capture experiments using a two-electrode flow cell device with AQ- and MFD-modified YP-50 porous carbon electrodes indicate that MFD systems perform on par with AQ systems. This work highlights relevant considerations for performing CO2 capture studies under continuous polarization conditions, illuminates key surface intermediates during carbon capture, and demonstrates the ability of our platform to screen novel RAO capture agents.
- 21 May 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessReal-time Monitoring of the Reversible Capture and Release of CO2 on Anthraquinone and Riboflavin-Modified Graphitic Electrodes using ATR-SEIRAS
Electrochemically mediated carbon capture (EMCC) offers a promising alternative to thermochemical carbon capture methods due to its higher energy efficiency and the ability to operate under standard conditions. Graphitic electrodes functionalized with redox-active organic (RAO) capture agents offer a unique opportunity for an inexpensive, abundant, and easily scalable system for direct EMCC. However, the mechanistic understanding and observation of intermediate capture states on carbon surfaces using spectroscopic signatures remains unexplored. Herein, we present in situ monitoring of the reversible capture and release of carbon dioxide (CO2) from graphene-on-gold electrodes modified with grafted anthraquinone (AQ) and a synthesized riboflavin derivative, 10-ethyl-3-methyl flavin derivative (MFD). These electrodes conveniently enable the use of surface-enhanced infrared absorption spectroscopy in an attenuated total reflectance configuration (ATR-SEIRAS). We successfully decouple the spectral responses of the CO2 reduction reaction (CO2RR) and CO2 capture processes by characterizing AQ- and MFD-modified electrodes under argon and CO2 atmospheres. Continuous polarization of the electrode to generate the reduced forms of AQ also generates carbonate (CO32-) peaks at 1640 cm-1 and 1380 cm-1 that overshadow the spectral responses of AQ-bound CO2. Conversely, reducing AQ or MFD under inert atmosphere, followed by introducing CO2 with no applied potential (i.e. at open circuit) results in the growth of distinct spectral features ~1710-1630 cm-1. The release of CO2 was observed through the regeneration of an intense carbonyl stretch at ~1660 cm-1 upon electrooxidation, corresponding with CV observations for AQ and MFD. Preliminary CO2 capture experiments using a two-electrode flow cell device with AQ- and MFD-modified YP-50 porous carbon electrodes indicate that MFD systems perform on par with AQ systems. This work highlights relevant considerations for performing CO2 capture studies under continuous polarization conditions, illuminates key surface intermediates during carbon capture, and demonstrates the ability of our platform to screen novel RAO capture agents.
- 20 January 2025
- Published by American Chemical Society (ACS) in ACS Electrochemistry
- Vol. 1 (4) , 476-485
Dissolved CO2 Modulates the Electrochemical Capacitance on Gold Electrodes
- 20 January 2025
- Published by American Chemical Society (ACS) in ACS Electrochemistry
- Vol. 1 (4) , 476-485
Dissolved CO2 Modulates the Electrochemical Capacitance on Gold Electrodes
- Open Access
- 2 April 2024
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 149 (10) , 2842-2854
Spectroelectrochemical determination of thiolate self-assembled monolayer adsorptive stability in aqueous and non-aqueous electrolytes
The stable potential window (SPW) is the potential range that an electrode modified by a self-assembled monolayer (SAM) can operate without desorbing the SAM. Here we introduce SPWs for aromatic SAMs at Au.
- 2 April 2024
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 149 (10) , 2842-2854
Open AccessSpectroelectrochemical determination of thiolate self-assembled monolayer adsorptive stability in aqueous and non-aqueous electrolytes
The stable potential window (SPW) is the potential range that an electrode modified by a self-assembled monolayer (SAM) can operate without desorbing the SAM. Here we introduce SPWs for aromatic SAMs at Au.
- Open Access
- 31 January 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (6) , 2435-2444
Monitoring SEIRAS on a Graphitic Electrode for Surface-Sensitive Electrochemistry: Real-Time Electrografting
The ubiquity of graphitic materials in electrochemistry makes it highly desirable to probe their interfacial behavior under electrochemical control. Probing the dynamics of molecules at the electrode/electrolyte interface is possible through spectroelectrochemical approaches involving surface-enhanced infrared absorption spectroscopy (SEIRAS). Usually, this technique can only be done on plasmonic metals such as gold or carbon nanoribbons, but a more convenient substrate for carbon electrochemical studies is needed. Here, we expanded the scope of SEIRAS by introducing a robust hybrid graphene-on-gold substrate, where we monitored electrografting processes occurring at the graphene/electrolyte interface. These electrodes consist of graphene deposited onto a roughened gold-sputtered internal reflection element (IRE) for attenuated total reflectance (ATR) SEIRAS. The capabilities of the graphene-gold IRE were demonstrated by successfully monitoring the electrografting of 4-amino-2,2,6,6-tetramethyl-1-piperidine N-oxyl (4-amino-TEMPO) and 4-nitrobenzene diazonium (4-NBD) in real time. These grafts were characterized using cyclic voltammetry and ATR-SEIRAS, clearly showing the 1520 and 1350 cm-1 NO2 stretches for 4-NBD and the 1240 cm-1 C-C, C-C-H, and N-Ȯ stretch for 4-amino-TEMPO. Successful grafts on graphene did not show the SEIRAS effect, while grafting on gold was not stable for TEMPO and had poorer resolution than on graphene-gold for 4-NBD, highlighting the uniqueness of our approach. The graphene-gold IRE is proficient at resolving the spectral responses of redox transformations, unambiguously demonstrating the real-time detection of surface processes on a graphitic electrode. This work provides ample future directions for real-time spectroelectrochemical investigations of carbon electrodes used for sensing, energy storage, electrocatalysis, and environmental applications.
- 31 January 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (6) , 2435-2444
Open AccessMonitoring SEIRAS on a Graphitic Electrode for Surface-Sensitive Electrochemistry: Real-Time Electrografting
The ubiquity of graphitic materials in electrochemistry makes it highly desirable to probe their interfacial behavior under electrochemical control. Probing the dynamics of molecules at the electrode/electrolyte interface is possible through spectroelectrochemical approaches involving surface-enhanced infrared absorption spectroscopy (SEIRAS). Usually, this technique can only be done on plasmonic metals such as gold or carbon nanoribbons, but a more convenient substrate for carbon electrochemical studies is needed. Here, we expanded the scope of SEIRAS by introducing a robust hybrid graphene-on-gold substrate, where we monitored electrografting processes occurring at the graphene/electrolyte interface. These electrodes consist of graphene deposited onto a roughened gold-sputtered internal reflection element (IRE) for attenuated total reflectance (ATR) SEIRAS. The capabilities of the graphene-gold IRE were demonstrated by successfully monitoring the electrografting of 4-amino-2,2,6,6-tetramethyl-1-piperidine N-oxyl (4-amino-TEMPO) and 4-nitrobenzene diazonium (4-NBD) in real time. These grafts were characterized using cyclic voltammetry and ATR-SEIRAS, clearly showing the 1520 and 1350 cm-1 NO2 stretches for 4-NBD and the 1240 cm-1 C-C, C-C-H, and N-Ȯ stretch for 4-amino-TEMPO. Successful grafts on graphene did not show the SEIRAS effect, while grafting on gold was not stable for TEMPO and had poorer resolution than on graphene-gold for 4-NBD, highlighting the uniqueness of our approach. The graphene-gold IRE is proficient at resolving the spectral responses of redox transformations, unambiguously demonstrating the real-time detection of surface processes on a graphitic electrode. This work provides ample future directions for real-time spectroelectrochemical investigations of carbon electrodes used for sensing, energy storage, electrocatalysis, and environmental applications.
- 1 January 1991
- Published by Walter de Gruyter GmbH in Journal of Optical Communications
- Vol. 12 (2) , 47-49
Two-Channel Optical Fiber Transmission using Polarization Division Multiplexing
Article Two-Channel Optical Fiber Transmission using Polarization Division Multiplexing was published on June 1, 1991 in the journal Journal of Optical Communications (volume 12, issue 2).
- 1 January 1991
- Published by Walter de Gruyter GmbH in Journal of Optical Communications
- Vol. 12 (2) , 47-49
Two-Channel Optical Fiber Transmission using Polarization Division Multiplexing
Article Two-Channel Optical Fiber Transmission using Polarization Division Multiplexing was published on June 1, 1991 in the journal Journal of Optical Communications (volume 12, issue 2).