UKUliana Kovalko

Uliana Kovalko

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Uliana Kovalko has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Morphology of the Veins in Healthy Individuals in the Area of the Sapheno-Femoral Junction during Normal Breathing, Valsalva Maneuver and Ujjayi Breath

    by Uliana Kovalko, Agata Kawalec, Katarzyna Bulińska, Paweł Latacz, Marian Simka

    Objectives: Valsalva maneuver is performed during strength physical exercises, because it stabilizes the torso through increased intra-abdominal pressure. By contrast, yoga practitioners are discouraged from Valsalva. Instead, they use ujjayi breath, which consists of unstopped breathing through the narrowed glottis. Methods: This study was an observational research performed in healthy participants. The aim of this study was to evaluate veins in the groin area during different types of breathing. We examined 10 healthy people in the standing body position during: a) normal breathing b) Valsalva maneuver c) ujjayi breath. We measured the cross-sectional areas of the femoral and the great saphenous veins in the proximity to the sapheno-femoral junction. Results: In comparison with normal breathing, there were only slight dilatations of examined veins during Valsalva and ujjayi. The cross-sectional area of femoral vein increased by 7-9% during Valsalva, and 2-4% during ujjayi; cross-sectional area of the great saphenous vein increased by 17-18% during Valsalva and 15-16% during ujjayi. In all participants the terminal and preterminal valves of the great saphenous vein were competent. However, Valsalva maneuver was associated with complete closure of the terminal valve, while during ujjayi breath this valve was opening and closing, following the breathing. Conclusions: In the standing body position both Valsalva and ujjayi breath have minimal effect on cross-sectional areas of the veins in the groin. On the other hand, ujjayi breath allows for undisturbed flow through the sapheno-femoral junction, while Valsalva interrupts this flow, with blood stagnation distally from the terminal valve.

  • Open Access

    Numerical Modeling of Venous Outflow from the Cranial Cavity in the Supine Body Position

    by Marian Simka, Joanna Czaja, Agata Kawalec, Paweł Latacz, Uliana Kovalko

    The hemodynamic relevance of differently located stenoses of the internal jugular veins remains undetermined. It particularly concerns nozzle-like strictures in the upper parts of these veins and stenotic jugular valves located at the end of these veins. This study was aimed at understanding flow disturbances caused by such stenoses. The computational fluid dynamics software Flowsquare+ was used. We constructed 3-dimensional models of the venous outflow, comprising two alternative routes: the tube representing the internal jugular vein and an irregular network representing the vertebral veins. At the beginning of the tube representing the internal jugular vein, differently shaped and sized short strictures representing nozzle-like strictures were built in. At the end of this tube, differently shaped membranes representing the jugular valve were built in. With the use of computational fluid dynamics modeling, we studied how these two obstacles influenced the outflow. We found that the most relevant outflow disturbances were evoked by the nozzle-like strictures in the upper part of the internal jugular vein that were small, long, or asymmetrically positioned. Very tight stenotic valves and septum-like malformed valve were equally hemodynamically relevant. These findings suggest that both upper and lower strictures of the internal jugular vein can be of clinical significance.


  • Open Access

    Numerical Modeling of the Venous Outflow from the Cranial Cavity in the Supine Body Position

    by Marian Simka, Joanna Czaja, Agata Kawalec, Paweł Latacz, Uliana Kovalko

    Hemodynamic relevance of differently located stenoses of the internal jugular veins remains undetermined. It particularly concerns nozzle-like strictures in the upper parts of these veins and stenotic jugular valves located at the end of this vein. This study was aimed at understanding flow disturbances caused by such stenoses. Computational fluid dynamics software, Flowsquare+, was used. We constructed 3-dimensional models of venous outflow, comprising two alternative routes: tube representing the internal jugular vein and irregular network representing the vertebral veins. At the beginning of the tube representing the internal jugular vein, differently-shaped and sized short strictures, representing nozzle-like strictures were built in. At the end of this tube, differently-shaped membranes, representing the jugular valve, were built in. With the use of computational fluid dynamics modeling, we studied how these two obstacles influenced the outflow. We found that the most relevant outflow disturbances were evoked by nozzle-like strictures in the upper part of the internal jugular vein that were either small, long or asymmetrically positioned. Very tight stenotic valves and septum-like malformed valve were equally hemodynamically relevant. These findings suggest that both upper and lower strictures of the internal jugular vein can be of clinical significance.