Elza Abdessater
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Elza Abdessater has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Amin Hossein
Laboratory of Physics and Physiology, Université Libre de Bruxelles, Brussels, Belgium
3 shared publications - Jérémy Rabineau
TIPs, Université Libre de Bruxelles, Brussels, Belgium
3 shared publications - Paniz Balali
Laboratory of Physics and Physiology (LPHYS), Département de Cardiologie, Hôpital Universitaire d’Erasme, Université libre de Bruxelles, Belgium
3 shared publications - Philippe van de Borne
Department of Cardiology, Hopital Erasme - Hopital Universitaire Bruxelles (HE-HUB), Université Libre de Bruxelles (ULB), Brussels, Belgium
2 shared publications - Vitalie Faoro
Cardio-pulmonary Exercise Laboratory, Faculty of Motor Sciences, Université Libre de Bruxelles, Brussels, Belgium
2 shared publications - Alexandre Almorad
Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel, Heart Rhythm Research Brussels, Postgraduate Program in Cardiac Electrophysiology and Pacing, Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
1 shared publication
Latest Publications
- Open Access
- 29 September 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 130
Detection of aortic opening using ECG-free seismocardiography: Performance and limitations in aortic valve disease patients
- 29 September 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 130
Open AccessDetection of aortic opening using ECG-free seismocardiography: Performance and limitations in aortic valve disease patients
- Open Access
A Novel Method for ECG-Free Heart Sound Segmentation in Patients with Severe Aortic Valve Disease
Severe aortic valve diseases (AVD) cause changes in heart sounds, making phonocardiogram (PCG) analyses challenging. This study presents a novel method for segmenting heart sounds without relying on an electrocardiogram (ECG), specifically targeting patients with severe AVD. Our algorithm enhances traditional Hidden Semi-Markov Models by incorporating signal envelope calculations and statistical tests to improve the detection of the first and second heart sounds (S1 and S2). We evaluated the method on the PhysioNet/CinC 2016 Challenge dataset and a newly acquired AVD-specific dataset. The method was tested on a total of 27,400 cardiac cycles. The proposed approach outperformed the existing methods, achieving a higher sensitivity and positive predictive value for S2, especially in the presence of severe heart murmurs. Notably, in patients with severe aortic stenosis, our proposed ECG-free method improved S2 sensitivity from 41% to 70%.
Open AccessA Novel Method for ECG-Free Heart Sound Segmentation in Patients with Severe Aortic Valve Disease
Severe aortic valve diseases (AVD) cause changes in heart sounds, making phonocardiogram (PCG) analyses challenging. This study presents a novel method for segmenting heart sounds without relying on an electrocardiogram (ECG), specifically targeting patients with severe AVD. Our algorithm enhances traditional Hidden Semi-Markov Models by incorporating signal envelope calculations and statistical tests to improve the detection of the first and second heart sounds (S1 and S2). We evaluated the method on the PhysioNet/CinC 2016 Challenge dataset and a newly acquired AVD-specific dataset. The method was tested on a total of 27,400 cardiac cycles. The proposed approach outperformed the existing methods, achieving a higher sensitivity and positive predictive value for S2, especially in the presence of severe heart murmurs. Notably, in patients with severe aortic stenosis, our proposed ECG-free method improved S2 sensitivity from 41% to 70%.
- Open Access
Smartphone-Derived Seismocardiography: Robust Approach for Accurate Cardiac Energy Assessment in Patients with Various Cardiovascular Conditions
Seismocardiography (SCG), a method for measuring heart-induced chest vibrations, is gaining attention as a non-invasive, accessible, and cost-effective approach for cardiac pathologies, diagnosis, and monitoring. This study explores the integration of SCG acquired through smartphone technology by assessing the accuracy of metrics derived from smartphone recordings and their consistency when performed by patients. Therefore, we assessed smartphone-derived SCG’s reliability in computing median kinetic energy parameters per record in 220 patients with various cardiovascular conditions. The study involved three key procedures: (1) simultaneous measurements of a validated hardware device and a commercial smartphone; (2) consecutive smartphone recordings performed by both clinicians and patients; (3) patients’ self-conducted home recordings over three months. Our findings indicate a moderate-to-high reliability of smartphone-acquired SCG metrics compared to those obtained from a validated device, with intraclass correlation (ICC) > 0.77. The reliability of patient-acquired SCG metrics was high (ICC > 0.83). Within the cohort, 138 patients had smartphones that met the compatibility criteria for the study, with an observed at-home compliance rate of 41.4%. This research validates the potential of smartphone-derived SCG acquisition in providing repeatable SCG metrics in telemedicine, thus laying a foundation for future studies to enhance the precision of at-home cardiac data acquisition.
Open AccessSmartphone-Derived Seismocardiography: Robust Approach for Accurate Cardiac Energy Assessment in Patients with Various Cardiovascular Conditions
Seismocardiography (SCG), a method for measuring heart-induced chest vibrations, is gaining attention as a non-invasive, accessible, and cost-effective approach for cardiac pathologies, diagnosis, and monitoring. This study explores the integration of SCG acquired through smartphone technology by assessing the accuracy of metrics derived from smartphone recordings and their consistency when performed by patients. Therefore, we assessed smartphone-derived SCG’s reliability in computing median kinetic energy parameters per record in 220 patients with various cardiovascular conditions. The study involved three key procedures: (1) simultaneous measurements of a validated hardware device and a commercial smartphone; (2) consecutive smartphone recordings performed by both clinicians and patients; (3) patients’ self-conducted home recordings over three months. Our findings indicate a moderate-to-high reliability of smartphone-acquired SCG metrics compared to those obtained from a validated device, with intraclass correlation (ICC) > 0.77. The reliability of patient-acquired SCG metrics was high (ICC > 0.83). Within the cohort, 138 patients had smartphones that met the compatibility criteria for the study, with an observed at-home compliance rate of 41.4%. This research validates the potential of smartphone-derived SCG acquisition in providing repeatable SCG metrics in telemedicine, thus laying a foundation for future studies to enhance the precision of at-home cardiac data acquisition.