  • High-Resolution GAGG-SiPM Detectors for Preclinical Coincidence SPECT

    by Haibo Wang, Jiahao Xie, Yifei Jin, Ling-Jian Meng, Junwei Du

    Coincidence detection of cascade decay in single photon emission computed tomography (SPECT) can enhance image quality by detecting true events and rejecting uncorrelated scatter. This study presents the development of high-resolution detectors based on 24 × 24 gadolinium aluminum gallium garnet (GAGG) arrays with a 1.0 mm pitch and 8 × 8 silicon photomultiplier (SiPM) arrays with a 3.2 mm pitch, which were designed for preclinical coincidence SPECT applications. Compton scatter events from annihilation photons were employed to mimic cascade photons and to evaluate the timing performance of the detectors. Moreover, the performance of the detectors with and without using 1 mm thick clear acrylic sheets as light guides was compared. Flood histograms showed that all GAGG elements were clearly identified except a small number of edge crystals when events with energies in a 100 - 250 keV energy window were used, and the use of the light guide improved crystal identification. The detectors with light guides achieved coincidence timing resolutions of 678 ± 143 ps, 571 ± 118 ps, and 374 ± 74 ps with events in 100 - 250 keV, 100 - 450 keV, and 400 - 650 keV energy windows, respectively. The corresponding values provided by detectors without the light guide were 551 ± 135 ps, 458 ± 114 ps, and 314 ± 68 ps. Energy resolutions at 511 keV were 9.2 ± 0.7% and 11.0 ± 0.7% for detectors with and without the light guide, respectively. These results demonstrated that the developed GAGG-SiPM detector with the light guide was a suitable candidate for developing preclinical coincidence SPECT systems.

  • Open Access

    High spatial resolution dual-ended readout PET detector based on continuous resistive layer silicon photomultiplier

    by Jiahao Xie, Haibo Wang, Junwei Du

    Objective. Continuous resistive layer position-sensitive silicon photomultiplier (CRL PS-SiPM) is a class of position-sensitive SiPMs developed for the readout of fine-pitch scintillator crystal arrays. This study aimed to evaluate the performance of dual-ended readout positron emission tomography (PET) detectors based on CRL PS-SiPMs and 0.5 mm pitch LYSO arrays. Approach. A dual-ended readout detector was constructed by coupling two CRL PS-SiPMs to both ends of a 10 × 10 array of polished LYSO elements, each measuring 0.44 × 0.44 × 20 mm 3 . Each CRL PS-SiPM had an active area of 6.24 × 6.24 mm 2 and was fabricated using 20 µ m microcells. Detector performance, including flood histogram quality, energy resolution, and coincidence timing resolution (CTR), was characterized at bias voltages ranging from 30.0 to 33.0 V in 0.5 V increments, and at 3 ° C, 14 ° C, and 24 ° C. Depth-of-interaction (DOI) resolution was evaluated at the optimal bias voltage determined from the flood histogram and at all three temperatures. Main results. Temperature had a negligible effect on detector performance, indicating that CRL PS-SiPMs are practical photodetector candidates for high spatial resolution PET scanners. All LYSO crystals were clearly resolved in the flood histograms. At 24 ° C and a bias voltage of 32.5 V, which provided the best flood histogram, the average energy resolution, CTR, and DOI resolution across all crystals were 22.7 ± 3.4%, 1152 ± 43 ps, and 1.78 ± 0.20 mm, respectively. Significance. These results demonstrate that CRL PS-SiPMs are promising photodetectors for high spatial resolution PET applications, particularly for systems requiring detectors with sub-millimeter pitch scintillator crystal arrays and DOI capability.

  • Ultra-High Spatial Resolution PET/Compton Detector Based on 0.32 mm Pitch GAGG Array

    by Jiahao Xie, Haibo Wang, Jinyi Qi, Simon R. Cherry, Junwei Du

    Positron emission tomography (PET)/Compton hybrid imaging has the potential to become a transformative molecular imaging modality, leveraging the high sensitivity of PET systems and the multi-tracer capability of Compton imaging. Achieving high spatial resolution in a PET/Compton hybrid imaging system requires detectors capable of simultaneously resolving sub-millimeter crystals and maintaining high energy resolution - a critical challenge for preclinical PET/Compton systems. In this work, we developed an ultra-high-resolution detector that can be used as the scatter layer detector of a high spatial resolution PET/Compton hybrid system. This detector incorporates a 28 × 28 array of 0.26 × 0.26 × 2 mm3 gadolinium aluminum gallium garnet (GAGG) elements (0.32 mm pitch) and a position-sensitive silicon photomultiplier (PS-SiPM). The detector demonstrated good performance: (1) flood histograms with clear crystal element separation, (2) an average energy resolution of 12.1 ± 1.8% at 511 keV, and (3) a coincidence timing resolution (CTR) of 1006 ± 78 ps obtained using a 100 - 600 keV energy window for event selection.

  • Open Access

    Dual-ended readout TOF-DOI PET detectors based on 3.2 mm and 1.6 mm pitch LYSO arrays

    by Haibo Wang, Jiahao Xie, Jinyi Qi, Simon R. Cherry, Junwei Du

    Background: The image quality of positron emission tomography (PET) can be significantly enhanced by using time-of-flight (TOF) and depth-of-interaction (DOI) information. PET detectors are pivotal in determining the TOF and DOI capabilities of PET scanners. Methods: This study developed and evaluated TOF-DOI PET detectors based on the dual-ended readout method and lutetium-yttrium oxyorthosilicate (LYSO) arrays with two different pitches and reflector configurations. Specifically, the performance of detectors based on three types of LYSO arrays with 20 mm thickness, 8 × 8 arrays with a 3.2 mm pitch, 16 × 16 arrays with a 1.6 mm pitch and normal reflectors, and 16 × 16 arrays with a 1.6 mm pitch and partial short reflectors, were assessed. Hamamatsu S14161-3050-08 silicon photomultiplier arrays were used as the photodetectors, and PETsys TOFPET2 was used as the readout electronics. Results: The flood histograms showed that all crystals in the three types of LYSO arrays were clearly resolved. The detectors based on the 8 × 8 LYSO arrays provided a coincidence timing resolution (CTR) of 207 ± 5 ps and a DOI resolution of 3.9 ± 0.6 mm. The detectors based on the 16 × 16 LYSO arrays with normal reflectors provided a CTR of 218 ± 7 ps and a DOI resolution of 2.6 ± 0.2 mm. In comparison, the detector based on the 16 × 16 LYSO arrays with partial short reflectors provided a CTR of 228 ± 11 ps and a DOI resolution of 2.9 ± 0.3 mm, and superior crystal resolvability compared to the detectors based on the 16 × 16 LYSO arrays with normal reflectors. Conclusion: These detectors are promising candidates for developing whole-body and brain PET scanners, offering effective sensitivity and uniform spatial resolution improvements across the field-of-view.


  • Development of Whole-Body TOF-DOI PET Detector Using Dual-Ended Readout Method

    by Haibo Wang, Jiahao Xie, Junwei Du

    Positron emission tomography (PET) is the most sensitive in vivo molecular instrumentation. The image quality of PET can be significantly enhanced by incorporating time-of-flight (TOF) and depth-of-interaction (DOI) information. In this study, whole-body TOF-DOI PET detectors based on the dual-ended readout method were developed to simultaneously provide good TOF and DOI information. Each detector consisted of two $8\times 8$ Hamamatsu S14161-3050-08 silicon photomultiplier (SiPM) arrays coupled to both ends of an $8\times 8$ lutetium-yttrium oxyorthosilicate (LYSO) array with a thickness of 20 mm. Both the LYSO and SiPM arrays had a pitch of 3.2 mm, allowing each LYSO element to be coupled to two SiPM elements, one at each end of the crystal, to achieve the optimal timing resolution. Experimental results demonstrated that the detectors achieved a coincidence timing resolution (CTR) of $234~\pm ~7$ ps, an energy resolution of 13.7 $\pm ~2.0$ %, and a DOI resolution of $2.6~\pm ~0.2$ mm. These results suggest that the developed detectors are suitable for constructing whole-body TOF-DOI PET scanners with uniform spatial resolution across the entire field-of-view.


  • High spatial resolution PET detectors based on 10 mm × 10 mm linearly-graded SiPMs and 0.5 mm pitch LYSO arrays

    by Jiahao Xie, Haibo Wang, Stefano Merzi, Giovanni Paternoster, Alberto Gola, Jinyi Qi, Simon R Cherry, Junwei Du

    Objective. Position-sensitive silicon photomultipliers (PS-SiPMs) are promising photodetectors for ultra-high spatial resolution small-animal positron emission tomography (PET) scanners. This paper evaluated the performance of the latest generation of linearly-graded SiPMs (LG-SiPMs), a type of PS-SiPM, for ultra-high spatial resolution PET applications using LYSO arrays from two vendors. Approach. Two dual-ended readout detectors were developed by coupling LG-SiPMs to both ends of the two LYSO arrays. Each LG-SiPM has an active area of 9.8 × 9.8 mm2. Both LYSO arrays consist of 20 × 20 arrays of 0.44 × 0.44 × 20 mm3 polished LYSOs with a pitch of 0.5 mm. The performance of the two detectors was compared in terms of flood histogram, energy resolution, timing resolution, and depth-of-interaction (DOI) resolutions. Main results. Flood histograms showed clear identification of all LYSO elements except for some edge crystals due to the larger size of the LYSO arrays compared to the active area of the LG-SiPMs and the misalignment between LG-SiPMs and LYSO arrays in the assembled detectors. At a bias voltage of 37.0 V, the detectors utilizing the Tianle LYSO array and EBO LYSO array provided energy resolutions of 17.5 ± 2.2 and 18.6 ± 2.0%, timing resolutions of 0.75 ± 0.03 and 0.78 ± 0.03 ns, and DOI resolutions of 2.16 ± 0.15 and 2.31 ± 0.12 mm, respectively. Significance. The results presented in this paper demonstrate that the new generation LG-SiPMs are promising photodetectors for ultra-high spatial resolution small-animal PET scanner applications.


  • A Time-Walk and Timing-Shift Correction Method for Dual-Ended Readout TOF-DOI PET Detectors

    by Haibo Wang, Jiahao Xie, Jinyi Qi, Simon R. Cherry, Junwei Du

    Positron emission tomography (PET) detectors suffer from time-walk when the leading edge discriminator is employed for timing pick-off as well as a timing-shift when thick crystals are utilized due to the depth-of-interaction (DOI) effect. In this study, a combined time-walk and timing-shift correction method was proposed for dual-ended readout PET detectors. To evaluate the proposed method, a pair of dual-ended readout PET detectors was constructed. Each detector was based on two Hamamatsu S14161-3050-08 silicon photomultiplier (SiPM) arrays coupled to both ends of an $8\times 8$ arrays of $3.1\times 3.1\times 20~{\mathrm { mm}}^{3}$ lutetium-yttrium oxyorthosilicate crystals with a 3.2-mm pitch. By employing the relationship between the energies and detected time differences of events, the time-walk and timing-shift were effectively corrected. The coincidence time resolution of the two detectors improved from $260.7~\pm ~1.0$ ps to $229.4~\pm ~1.0$ ps when a 400–650 keV energy window was used to select events. These results demonstrate the effectiveness of the proposed time-walk and timing-shift correction method.


  • PET Detectors Based on Multi-Resolution SiPM Arrays

    by Jiahao Xie, Haibo Wang, Simon R. Cherry, Junwei Du

    Almost all high spatial resolution positron emission tomography (PET) detectors based on pixelated scintillator arrays utilize crystal arrays with smaller pitches than photodetector arrays, leading to challenges in resolving edge crystals. To address this issue, this paper introduces a novel multi-resolution silicon photomultiplier (SiPM) array design aimed at decreasing the number of readout channels required while maintaining the crystal resolvability of the detector, especially for edge crystals. The performance of a pseudo 9 × 9 multi-resolution SiPM array, consisting of 6.47 × 6.47 mm, 6.47 × 3.07 mm, and 3.07 × 3.07 mm SiPMs, was compared to those of a pseudo 8 × 8 SiPM array with a 6.8 mm pitch, and a 16 × 16 SiPM array with a 3.4 mm pitch using a 36 × 36 LYSO array with a pitch of 1.5 mm. The large-size pseudo SiPMs were implemented by digitally grouping multiple 3.07 × 3.07 mm SiPMs. The flood histograms show that the edge crystal resolvability of the pseudo 9 × 9 multi-resolution SiPM array is comparable to that of the 16 × 16 SiPM array and is significantly better than that of the 8 × 8 SiPM array.