Zhihua Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhihua Li has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Fuxuan Ma
College of Shipbuilding Engineering, Harbin Engineering University, Harbin 150001, China
3 shared publications - Fan Zhu2 shared publications
Meng Zhang
2 shared publicationsXianqiang Qu
2 shared publications- Fan Zhu
Yantai Research Institute, Harbin Engineering University, Yantai 264000, China
1 shared publication - Meng Zhang
College of Shipbuilding Engineering, Harbin Engineering University, Harbin 150001, China
1 shared publication
Latest Publications
- 29 June 2024
- Published by Elsevier in Ocean Engineering
- Vol. 309
A monitoring method for wind loads exerted on offshore gravity wind turbine through optimised mathematical model
- 29 June 2024
- Published by Elsevier in Ocean Engineering
- Vol. 309
A monitoring method for wind loads exerted on offshore gravity wind turbine through optimised mathematical model
- Open Access
- 27 March 2024
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 12 (4) , 563
Identification of Wind Load Exerted on the Jacket Wind Turbines from Optimally Placed Strain Gauges Using C-Optimal Design and Mathematical Model Reduction
Wind turbine towers experience complex dynamic loads during actual operation, and these loads are difficult to accurately predict in advance, which may lead to inaccurate structural fatigue and strength assessment during the structural design phase, thereby posing safety risks to the wind turbine tower. However, online monitoring of wind loads has become possible with the development of load identification technology. Therefore, an identification method for wind load exerted on wind turbine towers was developed in this study to estimate the wind loads using structural strain, which can be used for online monitoring of wind loads. The wind loads exerted on the wind turbine tower were simplified into six equivalent concentrated forces on the topside of the tower, and the initial mathematical model for wind load identification was established based on dynamic load identification theory in the frequency domain, in which many candidate sensor locations and directions were considered. Then, the initial mathematical model was expressed as a linear system of equations. A numerical example was used to verify the accuracy and stability of the initial mathematical model for the wind load identification, and the identification results indicate that the initial mathematical model combined with the Moore–Penrose inverse algorithm can provide stable and accurate reconstruction results. However, the initial mathematical model uses too many sensors, which is not conducive to engineering applications. Therefore, D-optimal and C-optimal design methods were used to reduce the dimension of the initial mathematical model and determine the location and direction of strain gauges. The C-optimal design method adopts a direct optimisation search strategy, while the D-optimal design method adopts an indirect optimisation search strategy. Then, four numerical examples of wind load identification show that dimensionality reduction of the mathematical model leads to high accuracy, in which the C-optimal design algorithm provides more robust identification results. Moreover, the fatigue damage calculated based on the load identification wind loads closely approximates that derived from finite element simulation wind load, with a relative error within 6%. Therefore, the load identification method developed in this study offers a pragmatic solution for the accurate acquisition of the actual wind load of a wind turbine tower.
- 27 March 2024
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 12 (4) , 563
Open AccessIdentification of Wind Load Exerted on the Jacket Wind Turbines from Optimally Placed Strain Gauges Using C-Optimal Design and Mathematical Model Reduction
Wind turbine towers experience complex dynamic loads during actual operation, and these loads are difficult to accurately predict in advance, which may lead to inaccurate structural fatigue and strength assessment during the structural design phase, thereby posing safety risks to the wind turbine tower. However, online monitoring of wind loads has become possible with the development of load identification technology. Therefore, an identification method for wind load exerted on wind turbine towers was developed in this study to estimate the wind loads using structural strain, which can be used for online monitoring of wind loads. The wind loads exerted on the wind turbine tower were simplified into six equivalent concentrated forces on the topside of the tower, and the initial mathematical model for wind load identification was established based on dynamic load identification theory in the frequency domain, in which many candidate sensor locations and directions were considered. Then, the initial mathematical model was expressed as a linear system of equations. A numerical example was used to verify the accuracy and stability of the initial mathematical model for the wind load identification, and the identification results indicate that the initial mathematical model combined with the Moore–Penrose inverse algorithm can provide stable and accurate reconstruction results. However, the initial mathematical model uses too many sensors, which is not conducive to engineering applications. Therefore, D-optimal and C-optimal design methods were used to reduce the dimension of the initial mathematical model and determine the location and direction of strain gauges. The C-optimal design method adopts a direct optimisation search strategy, while the D-optimal design method adopts an indirect optimisation search strategy. Then, four numerical examples of wind load identification show that dimensionality reduction of the mathematical model leads to high accuracy, in which the C-optimal design algorithm provides more robust identification results. Moreover, the fatigue damage calculated based on the load identification wind loads closely approximates that derived from finite element simulation wind load, with a relative error within 6%. Therefore, the load identification method developed in this study offers a pragmatic solution for the accurate acquisition of the actual wind load of a wind turbine tower.
- 23 March 2024
- Published by Elsevier in Ocean Engineering
- Vol. 301
A reconstruction method for structural stress distribution of wind turbine tower using optimised mathematical model
- 23 March 2024
- Published by Elsevier in Ocean Engineering
- Vol. 301
A reconstruction method for structural stress distribution of wind turbine tower using optimised mathematical model