Mustafa Esat Coşkun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Mustafa Esat Coşkun has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Şenol Gürsoy
Karabük Üniversitesi, Mühendislik Fakültesi
2 shared publications - Erhan Eren
KARABUK UNIVERSITY, INSTITUTE OF GRADUATE PROGRAMS
1 shared publication - İsMail Tozlu
Karabük Üniversitesi, Mühendislik Fakültesi
1 shared publication - Zehra Şule Gari̇p
Karabük Üniversitesi
1 shared publication
Latest Publications
- 15 September 2026
- Published by Gumushane University Journal of Science and Technology Institute in Gümüşhane Üniversitesi Fen Bilimleri Enstitüsü Dergisi
- Vol. 16 (4) , 1276-1300
Effects of the retrofit phases on structural performance of an existing school building
In regions subject to intense seismic activity, school buildings play a critical role in post-disaster sheltering, human use, and overall disaster management. For this reason, performance assessment and strengthening of existing school buildings remain important research topics. Strengthening such structures often requires the combined use of multiple techniques. In the literature, studies on school building rehabilitation typically compare the existing condition only with the final strengthened state. In contrast, this study investigates not only the final strengthening condition but also the individual effects of each strengthening method on structural behavior. An existing reinforced concrete school building was strengthened through the addition of reinforced concrete shear walls and the application of FRP wrapping. Structural evaluations were conducted in four stages: the existing condition (Stage 1), structural system strengthening by adding new shear walls (Stage 2), element-based strengthening through FRP wrapping (Stage 3), and the final strengthened condition (Stage 4), which combines the interventions of Stages 2 and 3. Comparisons were made both at the global (systemic) level and on an element-by-element basis. The findings indicate that a system-level strengthening strategy incorporating reinforced concrete shear walls is most effective in reducing seismic demand on damaged elements. Conversely, to enhance the capacity of critical or previously damaged elements, element-based strengthening using FRP wrapping is a more suitable approach.
- 15 September 2026
- Published by Gumushane University Journal of Science and Technology Institute in Gümüşhane Üniversitesi Fen Bilimleri Enstitüsü Dergisi
- Vol. 16 (4) , 1276-1300
Effects of the retrofit phases on structural performance of an existing school building
In regions subject to intense seismic activity, school buildings play a critical role in post-disaster sheltering, human use, and overall disaster management. For this reason, performance assessment and strengthening of existing school buildings remain important research topics. Strengthening such structures often requires the combined use of multiple techniques. In the literature, studies on school building rehabilitation typically compare the existing condition only with the final strengthened state. In contrast, this study investigates not only the final strengthening condition but also the individual effects of each strengthening method on structural behavior. An existing reinforced concrete school building was strengthened through the addition of reinforced concrete shear walls and the application of FRP wrapping. Structural evaluations were conducted in four stages: the existing condition (Stage 1), structural system strengthening by adding new shear walls (Stage 2), element-based strengthening through FRP wrapping (Stage 3), and the final strengthened condition (Stage 4), which combines the interventions of Stages 2 and 3. Comparisons were made both at the global (systemic) level and on an element-by-element basis. The findings indicate that a system-level strengthening strategy incorporating reinforced concrete shear walls is most effective in reducing seismic demand on damaged elements. Conversely, to enhance the capacity of critical or previously damaged elements, element-based strengthening using FRP wrapping is a more suitable approach.
- Open Access
- 28 March 2024
- Published by Erzincan Universitesi Fen Bilimleri Ensitusu Dergisi in Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi
- Vol. 17 (1) , 279-300
Evaluation of Different Strengthening Projects of Yenice Kalaycılar Primary School According to 2007 and 2019 Turkish Earthquake Regulations
Earthquakes that frequently occur in Turkey may cause structural damage in structures, and/or existing structures cannot provide the new earthquake code requirements. This matter requires us to check the static suitability of existing structures and strengthen them when necessary. In this article, a comparative evaluation of two different strengthening projects, which are considered to be implemented in Kalaycılar primary school in Yenice district of Karabük province, according to 2007 and 2019 Turkish earthquake regulations, is made. For this purpose, the survey projects of the said school building were first prepared, and laboratory experiments were carried out according to the level of comprehensive knowledge. Then, according to the findings obtained from the laboratory experiments, the performance analyses of the school building in question were made according to the 2007 and 2019 Turkish earthquake regulations. According to carried out the performance analyses, two different strengthening projects prepared for the school building have presented some results and suggestions by comparing the 2007 and 2019 Turkish earthquake regulations.
- 28 March 2024
- Published by Erzincan Universitesi Fen Bilimleri Ensitusu Dergisi in Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi
- Vol. 17 (1) , 279-300
Open AccessEvaluation of Different Strengthening Projects of Yenice Kalaycılar Primary School According to 2007 and 2019 Turkish Earthquake Regulations
Earthquakes that frequently occur in Turkey may cause structural damage in structures, and/or existing structures cannot provide the new earthquake code requirements. This matter requires us to check the static suitability of existing structures and strengthen them when necessary. In this article, a comparative evaluation of two different strengthening projects, which are considered to be implemented in Kalaycılar primary school in Yenice district of Karabük province, according to 2007 and 2019 Turkish earthquake regulations, is made. For this purpose, the survey projects of the said school building were first prepared, and laboratory experiments were carried out according to the level of comprehensive knowledge. Then, according to the findings obtained from the laboratory experiments, the performance analyses of the school building in question were made according to the 2007 and 2019 Turkish earthquake regulations. According to carried out the performance analyses, two different strengthening projects prepared for the school building have presented some results and suggestions by comparing the 2007 and 2019 Turkish earthquake regulations.