PDPeter K. Day

Peter K. Day

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Peter K. Day has a total of 179 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Temperature and magnetic field limits of a kinetic inductance traveling-wave parametric amplifier

    by Lucas M. Janssen, Farzad Faramarzi, Henry G. LeDuc, Sahil Patel, Gianluigi Catelani, Peter K. Day, Yoichi Ando, Christian Dickel


  • Improved Modeling of Quasi-Static Thermal and Optical Response of Lumped-Element Aluminum Manganese KIDs

    by Adriana Gavidia, Sunil Golwala, Andrew D. Beyer, Daniel Cunnane, Peter K. Day, Fabien Defrance, Clifford F. Frez, Xiaolan Huang, Junhan Kim, Jean-Marc Martin, et al.

    We report on the characterization of AlMn ki netic inductance detectors (KIDs) under consideration for use in the Next-generation Extended Wavelength-MUltiband Sub/millimeter Inductance Camera (NEW-MUSIC) [1] on the Leighton Chajnantor Telescope (LCT). NEW-MUSIC will cover 80-420 GHz, split into six spectral bands, with polarimetry. This broad spectral coverage will enable study of a range of scientific topics such as the accretion and feedback in galaxies and galaxy cluster evolution via the Sunyaev-Zeldovich effect, the transient synchrotron emission from the explosive deaths of massive stars and other time-domain phenomena, and dusty sources from low to high redshift (with polarization). Al KIDs have already been demonstrated for four bands centered at 150, 220, 275, and 350 GHz and will also be used for the 405 GHz band [1]. AlMn KIDs are a candidate for the 90 GHz band, as Al's pair-breaking energy is too high. However, AlMn has only barely been explored as a KID material. To this end, we first improved the modeling techniques used for KIDs within BCS theory by eliminating the use of analytical approximations for the expressions of the complex conductivity and found these changes reduced fit parameter degeneracy in the analysis of AlMn. Then, we tested the addition of a gap smearing parameter, a standard extension to BCS theory in use for materials for which the BCS model appears unsatisfactory, such as high kinetic inductance materials, and found that the model without this term is preferred by the data. We thus conclude that our AlMn resonators do not suffer from significant gap smearing. Finally, we observed optical response of the AlMn KIDs to mm-wave radiation and attempted to measure their optical efficiency, but the small response of these devices to optical loading at the operating temperatures attempted prevented us from obtaining meaningful constraints. Nevertheless, our data display AlMn's potential as a KID material for the 60–100 GHz frequency range.

  • Open Access

    Significant noise improvement in a Kinetic Inductance Phonon-Mediated detector by use of a wideband parametric amplifier

    by K. Ramanathan, O. Wen, T. Aralis, R. Basu Thakur, B. Bumble, Y.-Y. Chang, P.K. Day, B.H. Eom, H.G. Leduc, B.J. Sandoval, et al.

    Microwave Kinetic Inductance Detectors (MKIDs) have been demonstrated as capable phonon sensors when coupled to crystalline substrates, and have been proposed as detectors for next-generation rare-event searches such as for the direct detection of dark matter. These Kinetic Inductance Phonon-Mediated (KIPM) detector designs, favoring large superconducting absorber volumes and high readout powers, are oftentimes limited in their sensitivity by low temperature amplifier noise introduced in the signal readout chain. We report here an effort to couple a wideband Kinetic Inductance Traveling Wave Parametric Amplifier (KI-TWPA), operated near the Standard Quantum Limit of minimal added amplifier noise, to sensors spanning a 70 MHz bandwidth at 3.5 GHz. This results in a ∼ 5× improvement in the inferred detector energy resolution in the best sensor and highlights the potential of constructing 𝒪(100) meV resolving phonon-mediated particle detectors. We detail limitations introduced by lossy passive components, degraded RF responsivity, and microphysical noise sources like two-level systems (TLS), in achieving ultimate quantum-limited system noise levels.

  • Low-Frequency Noise Performance of Microstrip-Coupled Lumped-Element Aluminum KIDs Using Hydrogenated Amorphous Silicon Parallel-Plate Capacitors for NEW-MUSIC

    by Simon Hempel-Costello, Sunil R. Golwala, Andrew D. Beyer, Daniel Cunnane, Peter K. Day, Fabien Defrance, Clifford F. Frez, Adriana Gavidia, Junhan Kim, Jean-Marc Martin, et al.

    We present measurements of the low-frequency noise of a microstrip-coupled, lumped-element aluminum kinetic inductance detector design that uses a hydrogenated amorphous silicon parallel-plate capacitor (Al/a-Si:H MS-PPC-LEKID), a design under development for the Next-generation Extended Wavelength MUltiband Submillimeter Inductance Camera (NEWMUSIC) on the Leighton Chajnantor Telescope (LCT). We show that, under dark conditions, this design's noise PSD is dominated by generation-recombination (GR) noise down to 0.1 Hz. Our measurements set upper limits on the low-frequency (0.01-1 Hz) two-level-system (TLS) noise of the a-Si:H material that are consistent with prior measurements at 0.1-10 kHz. By extrapolating these measurements to optically loaded operating conditions and comparing to prior measurements above 100 Hz of noise dominated by photon and quasiparticle statistics under optical load, we project that the Al/a-Si:H MS-PPC-LEKID design's noise PSD will be photon- and generation-recombination-noisedominated down to tenths of Hz under expected telescope onsky optical loads. These results are an important milestone toward demonstrating that Al/a-Si:H MS-PPC-LEKIDs, and a-Si:H PPC-KIDs more generally, are a viable new detector technology for even low modulation-rate applications such as astronomy.


  • In Situ Interferometric Spatial Mapping of a Microwave Kinetic Inductance Detector Array

    by Chris Albert, Ritoban Basu Thakur, Farzad Faramarzi, Byeong Ho Eom, Sumit Dahal, Andrew Bear, Reinier Janssen, Henry LeDuc, Thomas Stevenson, Peter Day

    We present a method of spatially mapping microwave kinetic inductance detector (MKID) arrays, in a dark setup. MKIDs are superconducting natively multiplexed resonators which enable kilopixel arrays, such as for the proposed Probe far-Infrared Mission for Astrophysics (PRIMA). In such telescope applications one must map the spatial location of each MKID with their individual resonance frequencies. Traditional LED arrays or beam-mapping methods become increasingly difficult as pixel spacing decreases, e.g., 900 $\mu$m separated MKIDs in the spectrometer module of PRIMA. Our new mapping technique uses a cryogenic interferometer in reflection mode. As on-resonance signals reflect from an MKID, they accrue a phase proportional to the path-length, exactly corresponding to their physical distance on the feedline. Specifically, we use a superconducting transmission line that has nonlinear kinetic inductance. The slow-wave structure of this nonlinear device is designed to have a signal speed of 0.64% the speed of light, enabling a compact system. Current biasing this line allows for varying the wave speed and ensuring that the phase measured is periodic within a nulling interferometric mode. Using this setup, we measure a length ordering that reflects the bimodal MKID distribution of a 44 pixel array of MKIDs designed for PRIMA which contains the same spacing as the final kilopixel array design.

  • Investigating the $\chi ^{(3)}$ Nonlinearity of a Josephson Junction Array for Travelling-Wave Parametric Amplification in the W-Band

    by Javier Navarro Montilla, Ryan C. Stephenson, Arnaud Barbier, Nikita Klimovich, Yves Bortolotti, Eduard F. C. Driessen, Peter K. Day, Boon-Kok Tan

    At microwave frequencies, Josephson junction arrays have been widely employed to create metamaterials exhibiting a third-order ($\chi ^{(3)}$) nonlinearity, analogous to the Kerr effect in optics. These nonlinear metamaterials enable parametric amplification, as in Josephson travelling-wave parametric amplifiers (JTWPAs), which achieve quantum-limited noise performance over multigigahertz bandwidths. The exceptional properties of JTWPAs make them ideal for the sensitive readout of weak microwave signals, with applications in quantum computing, astrophysics, and fundamental physics experiments. Extending JTWPAs to higher frequencies, such as the W-band (70–110 GHz), holds promise for first-stage amplification in astronomical receivers, lowering system noise; as well as for reading out emerging superconducting qubit architectures at these frequencies. In this work, we investigate the $\chi ^{(3)}$ nonlinear properties of Josephson arrays operating in the W-band as a step toward realizing parametric gain at these frequencies. We designed and fabricated an array composed of 704 Nb/Al-AlO$_{\mathrm{x}}$/Nb tunnel junctions and experimentally demonstrated four-wave mixing via idler tone generation, providing clear evidence of third-order nonlinearity. These results mark an important step toward novel millimetre-wave and submillimetre-wave parametric-amplifier-based receiver technologies.


  • A millimeter-wave photometric camera for long-range imaging through optical obscurants using kinetic inductance detectors

    by J. Sayers, D. Cunnane, S. Crystian, P. K. Day, F. Defrance, B. H. Eom, J. Greenfield, M. Hollister, B. R. Johnson, H. G. LeDuc, et al.

    Passive imaging through optical obscurants is a promising application for mm-wave sensing. We have thus developed the Superconducting Kinetic Inductance Passive Radiometer (SKIPR), a 150 GHz polarization-sensitive photometric camera optimized for terrestrial imaging using a focal plane array with 3840 kinetic inductance detectors (KIDs). We present a full description of the instrument design, with a particular emphasis on the cryogenic system based on a Gifford–McMahon cryocooler with a two-stage adiabatic demagnetization refrigerator and a dedicated 1.59 m crossed Dragone telescope with an altitude/azimuth mount. We include a detailed lab-based characterization of the KIDs, which results in a determination of their superconducting resonator parameters and optical properties. We also present in situ measurements from the telescope, including point-spread functions and noise characterization. In sum, we find that SKIPR performs as expected, providing diffraction-limited imaging with detector noise performance set by the random arrivals of photons from the ambient background. There is minimal variation in detector characteristics over the full SKIPR focal plane array, and the overall detector yield is 92%.


  • Top Cited Papers
    Open Access

    A 25-micrometer Single-Photon-Sensitive Kinetic Inductance Detector

    by Peter K. Day, Nicholas F. Cothard, Christopher Albert, Logan Foote, Elijah Kane, Byeong H. Eom, Ritoban Basu Thakur, Reinier M. J. Janssen, Andrew Beyer, Pierre M. Echternach, et al.

    We report measurements characterizing the performance of a kinetic inductance detector array designed for a wavelength of 25 microns and very low optical background level suitable for applications such as a far-infrared instrument on a cryogenically cooled space telescope. In a pulse-counting mode of operation at low optical flux, the detectors can resolve individual 25-micron photons. In an integrating mode, the detectors remain photon noise limited over more than 6 orders of magnitude in absorbed power from 70 zW to 200 fW, with a limiting noise equivalent power of 4.6 × 10 − 20 W Hz − 1 at 1 Hz. In addition, the detectors are highly stable with flat power spectra under optical load down to 1 mHz. Operational parameters of the detector are determined including the efficiency of conversion of the incident optical power into quasiparticles in the aluminum absorbing element and the quasiparticle self-recombination constant. Published by the American Physical Society 2024


  • Open Access

    Plasma-enhanced atomic layer deposition of titanium nitride for superconducting devices

    by John Femi-Oyetoro, Sasha Sypkens, Henry LeDuc, Matthew Dickie, Andrew Beyer, Peter Day, Frank Greer

    This study examines the superconducting properties of titanium nitride (TiN) deposited via plasma-enhanced atomic layer deposition on both planar and three-dimensional (3D) structures. Our deposition method achieves consistent uniformity, maintaining sheet resistance (R□) > 95% across a 6-in. wafer, crucial for large-scale superconducting device fabrication and yield optimization. The planar films, akin to reactive-sputtered TiN, reached a critical temperature (Tc) of 4.35 K at a thickness of ≈40 nm. For aspect ratios (ARs) between 2 and 40, we observed a single transition of ≈2 K at ARs between 2 and 10.5, and multiple transitions at ARs > 10.5. We discuss mechanisms influencing superconducting properties in the 3D structures, aligning with current and future superconducting technologies.