Mohammad Saber Azimi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mohammad Saber Azimi has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Habib Zaidi
Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Switzerland
7 shared publications Abass Alavi
3 shared publications- Hossein Arabi
Department of Medical Imaging, Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211, Geneva, Switzerland
3 shared publications Maryam Cheraghi
3 shared publicationsAmirhossein Sanaat
Division of Nuclear Medicine & Molecular Imaging, Geneva University Hospital, Geneva, Switzerland
2 shared publicationsFatemeh MahdiMaleki
2 shared publications
Latest Publications
- Open Access
- 30 October 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (21) , 215002
Nonlinear stability phenotypes and collapse dynamics of multi-organ radiomics in total-body PET imaging: toward digital twin-oriented robustness assessment
Objective. Radiomics analysis in positron emission tomography (PET) offers a high-dimensional representation of tissue characteristics, yet its reliability is limited by sensitivity to acquisition perturbations, particularly dose reduction. This study aims to introduce a nonlinear stability phenotyping framework to characterize dose–response behavior of multi-organ radiomics and evaluate their potential relevance for future digital twin-oriented applications. Approach. A multi-center dataset of 550 total-body PET scans was analyzed. Dose reduction was simulated using list-mode subsampling (dose reduction factor − DRF = 2–100). A total of 107 radiomics features were extracted per organ. Stability was quantified using intraclass correlation coefficient and summarized as stability fractions. Nonlinear models were fitted to organ- and feature-level trajectories. Stability phenotypes and critical thresholds were derived, along with organ-level instability metrics. Main results. Radiomics stability exhibited strongly nonlinear, organ-dependent behavior. Feature-level analysis identified frequent sigmoid-associated collapse patterns with high descriptive model fits ( R 2 > 0.90). The liver showed the highest instability burden (30.8% unstable features), followed by esophagus and kidneys (18%–20%). Texture features were the primary source of instability, whereas shape features remained robust. Organ-level trajectories demonstrated heterogeneous responses, with some organs maintaining high stability (0.80–0.95) across DRFs, while others showed sharp declines (down to 0.64). Linear (stable) behavior dominated at the organ level, though masking underlying nonlinear feature dynamics. Significance. Radiomics stability in total-body PET follows nonlinear, phenotype-driven dynamics with identifiable tipping points and organ-specific sensitivity. The proposed framework provides a behavior-based approach for evaluating radiomics robustness and supports the selection of reliable features and organs for robust quantitative imaging and may inform future digital twin-oriented applications.
- 30 October 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (21) , 215002
Open AccessNonlinear stability phenotypes and collapse dynamics of multi-organ radiomics in total-body PET imaging: toward digital twin-oriented robustness assessment
Objective. Radiomics analysis in positron emission tomography (PET) offers a high-dimensional representation of tissue characteristics, yet its reliability is limited by sensitivity to acquisition perturbations, particularly dose reduction. This study aims to introduce a nonlinear stability phenotyping framework to characterize dose–response behavior of multi-organ radiomics and evaluate their potential relevance for future digital twin-oriented applications. Approach. A multi-center dataset of 550 total-body PET scans was analyzed. Dose reduction was simulated using list-mode subsampling (dose reduction factor − DRF = 2–100). A total of 107 radiomics features were extracted per organ. Stability was quantified using intraclass correlation coefficient and summarized as stability fractions. Nonlinear models were fitted to organ- and feature-level trajectories. Stability phenotypes and critical thresholds were derived, along with organ-level instability metrics. Main results. Radiomics stability exhibited strongly nonlinear, organ-dependent behavior. Feature-level analysis identified frequent sigmoid-associated collapse patterns with high descriptive model fits ( R 2 > 0.90). The liver showed the highest instability burden (30.8% unstable features), followed by esophagus and kidneys (18%–20%). Texture features were the primary source of instability, whereas shape features remained robust. Organ-level trajectories demonstrated heterogeneous responses, with some organs maintaining high stability (0.80–0.95) across DRFs, while others showed sharp declines (down to 0.64). Linear (stable) behavior dominated at the organ level, though masking underlying nonlinear feature dynamics. Significance. Radiomics stability in total-body PET follows nonlinear, phenotype-driven dynamics with identifiable tipping points and organ-specific sensitivity. The proposed framework provides a behavior-based approach for evaluating radiomics robustness and supports the selection of reliable features and organs for robust quantitative imaging and may inform future digital twin-oriented applications.
- Open Access
- 25 April 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 122
Supervised vs. unsupervised radiomics reproducibility across dose-level variations and partial volume correction methods in total-body PET imaging
- 25 April 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 122
Open AccessSupervised vs. unsupervised radiomics reproducibility across dose-level variations and partial volume correction methods in total-body PET imaging
- Open Access
- 1 March 2026
- Published by American Association for the Advancement of Science (AAAS) in Computational and Structural Biotechnology Journal
- Vol. 35 (1)
Instrumentation Digital Twins in PET and SPECT Imaging: Current Status, Challenges, and Future Directions
Introduction: Digital twins (DTs) in nuclear medicine are data-synchronized, physics-based models that replicate positron emission tomography (PET) and single-photon emission computed tomography (SPECT) systems by linking validated simulations with scanner configuration and calibration inputs. Instrumentation DTs (iDTs) extend system modeling by enabling feedback-driven assessment of detector performance, collimation, electronics behavior, and acquisition conditions. This review summarizes recent developments in PET and SPECT iDTs and evaluates their roles in system optimization. Materials and Methods: A structured literature review was conducted, and applications were grouped into 6 domains: (a) calibration and performance optimization, (b) predictive maintenance and fault detection, (c) quantitative correction and protocol optimization, (d) dosimetry and reconstruction benchmarking, (e) synthetic data generation and artificial intelligence (AI) training, and (f) scanner design and geometry evaluation. Attention was given to implementations integrating established detector and system models into unified, data-linked workflows. Results: Evidence shows that iDTs support virtual calibration, protocol assessment, and algorithm benchmarking. They can simulate detector misalignment and probabilistic hardware failures, factors relevant for high-resolution and small-animal imaging. iDTs also enable exploration of geometry changes, dose-sensitivity trade-offs, and long axial field-of-view configurations. However, current approaches remain fragmented, depend on vendor-specific components, and provide limited telemetry integration. Validation still relies mainly on standard National Electrical Manufacturers Association and quality control procedures. Conclusion: Future progress will benefit from modular and standardized iDT frameworks incorporating hardware realism, reliability modeling, and hybrid AI–physics strategies. Fully developed iDTs can improve calibration stability, support adaptive protocol design, enable early detection of component degradation, guide dose optimization, and accelerate virtual prototyping of next-generation PET and SPECT systems.
- 1 March 2026
- Published by American Association for the Advancement of Science (AAAS) in Computational and Structural Biotechnology Journal
- Vol. 35 (1)
Open AccessInstrumentation Digital Twins in PET and SPECT Imaging: Current Status, Challenges, and Future Directions
Introduction: Digital twins (DTs) in nuclear medicine are data-synchronized, physics-based models that replicate positron emission tomography (PET) and single-photon emission computed tomography (SPECT) systems by linking validated simulations with scanner configuration and calibration inputs. Instrumentation DTs (iDTs) extend system modeling by enabling feedback-driven assessment of detector performance, collimation, electronics behavior, and acquisition conditions. This review summarizes recent developments in PET and SPECT iDTs and evaluates their roles in system optimization. Materials and Methods: A structured literature review was conducted, and applications were grouped into 6 domains: (a) calibration and performance optimization, (b) predictive maintenance and fault detection, (c) quantitative correction and protocol optimization, (d) dosimetry and reconstruction benchmarking, (e) synthetic data generation and artificial intelligence (AI) training, and (f) scanner design and geometry evaluation. Attention was given to implementations integrating established detector and system models into unified, data-linked workflows. Results: Evidence shows that iDTs support virtual calibration, protocol assessment, and algorithm benchmarking. They can simulate detector misalignment and probabilistic hardware failures, factors relevant for high-resolution and small-animal imaging. iDTs also enable exploration of geometry changes, dose-sensitivity trade-offs, and long axial field-of-view configurations. However, current approaches remain fragmented, depend on vendor-specific components, and provide limited telemetry integration. Validation still relies mainly on standard National Electrical Manufacturers Association and quality control procedures. Conclusion: Future progress will benefit from modular and standardized iDT frameworks incorporating hardware realism, reliability modeling, and hybrid AI–physics strategies. Fully developed iDTs can improve calibration stability, support adaptive protocol design, enable early detection of component degradation, guide dose optimization, and accelerate virtual prototyping of next-generation PET and SPECT systems.
- Open Access
- 5 November 2025
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 53 (4) , 2830-2861
Critical review of partial volume correction methods in PET and SPECT imaging: benefits, pitfalls, challenges, and future outlook
Purpose: Partial volume effects (PVE) remain a major challenge in quantitative single-photon emission computed tomography (SPECT) and positron emission tomography (PET) imaging, often compromising both accuracy and reproducibility. While numerous Partial Volume Correction (PVC) methods have been proposed, their clinical translation is still limited. This review provides a clinically oriented evaluation of PVC methods with a particular focus on state-of-the-art applications in neurology, cardiovascular imaging, oncology, and radiopharmaceutical therapy dosimetry, highlighting where these techniques offer the greatest added value. In addition, we outline which PVC techniques have the potential to be used in clinical practice and which remain primarily suited for research purposes, along with their suitability in each of the above-mentioned clinical domains. Finally, this review addresses the central question of whether PVC is essential in clinical practice or whether its impact is context dependent. Methods: This review categorizes PVC approaches into three partially overlapping classes: reconstruction-based, post-reconstruction-based, and AI-driven or hybrid methods. Each class is further divided into anatomical and non-anatomical subcategories. We systematically compare their clinical applicability across key dimensions: quantitative accuracy, lesion detectability, robustness to noise and artifacts, anatomical dependence, generalizability across scanners and tracers, and clinical readiness. Results: PVC techniques often improve quantitative accuracy in small structures and in regions affected by spill-over from adjacent high-uptake tissues. However, these benefits can come at the cost of increased noise or edge artifacts, which may limit their robustness for routine clinical use. Post-reconstruction methods are sensitive to segmentation errors, while AI-driven models, despite their promise, require further validation using clinical benchmarks, comparison to ground truth, and testing on diverse datasets. Issues, such as generalizability and interpretability remain significant barriers. Conclusion: This review emphasizes the importance of application-tailored PVC protocols for reliable quantitative imaging in neurology, cardiology, oncology, and radiopharmaceutical therapy dosimetry. Not all PVC methods are beneficial; some may even impair interpretation in certain contexts. We provide a practical overview of which PVC approaches are most beneficial for each clinical scenario, aiming to guide both researchers and clinicians in selecting appropriate techniques for future studies and routine practice, and also outline key areas requiring further development for broader integration into research and clinical workflows. Graphical
- 5 November 2025
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 53 (4) , 2830-2861
Open AccessCritical review of partial volume correction methods in PET and SPECT imaging: benefits, pitfalls, challenges, and future outlook
Purpose: Partial volume effects (PVE) remain a major challenge in quantitative single-photon emission computed tomography (SPECT) and positron emission tomography (PET) imaging, often compromising both accuracy and reproducibility. While numerous Partial Volume Correction (PVC) methods have been proposed, their clinical translation is still limited. This review provides a clinically oriented evaluation of PVC methods with a particular focus on state-of-the-art applications in neurology, cardiovascular imaging, oncology, and radiopharmaceutical therapy dosimetry, highlighting where these techniques offer the greatest added value. In addition, we outline which PVC techniques have the potential to be used in clinical practice and which remain primarily suited for research purposes, along with their suitability in each of the above-mentioned clinical domains. Finally, this review addresses the central question of whether PVC is essential in clinical practice or whether its impact is context dependent. Methods: This review categorizes PVC approaches into three partially overlapping classes: reconstruction-based, post-reconstruction-based, and AI-driven or hybrid methods. Each class is further divided into anatomical and non-anatomical subcategories. We systematically compare their clinical applicability across key dimensions: quantitative accuracy, lesion detectability, robustness to noise and artifacts, anatomical dependence, generalizability across scanners and tracers, and clinical readiness. Results: PVC techniques often improve quantitative accuracy in small structures and in regions affected by spill-over from adjacent high-uptake tissues. However, these benefits can come at the cost of increased noise or edge artifacts, which may limit their robustness for routine clinical use. Post-reconstruction methods are sensitive to segmentation errors, while AI-driven models, despite their promise, require further validation using clinical benchmarks, comparison to ground truth, and testing on diverse datasets. Issues, such as generalizability and interpretability remain significant barriers. Conclusion: This review emphasizes the importance of application-tailored PVC protocols for reliable quantitative imaging in neurology, cardiology, oncology, and radiopharmaceutical therapy dosimetry. Not all PVC methods are beneficial; some may even impair interpretation in certain contexts. We provide a practical overview of which PVC approaches are most beneficial for each clinical scenario, aiming to guide both researchers and clinicians in selecting appropriate techniques for future studies and routine practice, and also outline key areas requiring further development for broader integration into research and clinical workflows. Graphical
- Open Access
- 23 July 2025
- Published by Elsevier in NeuroImage
- Vol. 318, 121398
Toward standardization: Assessing the reproducibility of radiomics features in partial volume-corrected brain PET images
- 23 July 2025
- Published by Elsevier in NeuroImage
- Vol. 318, 121398
Open AccessToward standardization: Assessing the reproducibility of radiomics features in partial volume-corrected brain PET images
- Open Access
- 8 July 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 196 (Pt A) , 110733
Deep supervised transformer-based noise-aware network for low-dose PET denoising across varying count levels
- 8 July 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 196 (Pt A) , 110733
Open AccessDeep supervised transformer-based noise-aware network for low-dose PET denoising across varying count levels
- Open Access
- 1 March 2024
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 14 (3) , 2146-2164
Deep learning-based partial volume correction in standard and low-dose positron emission tomography-computed tomography imaging
Background: Positron emission tomography (PET) imaging encounters the obstacle of partial volume effects, arising from its limited intrinsic resolution, giving rise to (I) considerable bias, particularly for structures comparable in size to the point spread function (PSF) of the system; and (II) blurred image edges and blending of textures along the borders. We set out to build a deep learning-based framework for predicting partial volume corrected full-dose (FD + PVC) images from either standard or low-dose (LD) PET images without requiring any anatomical data in order to provide a joint solution for partial volume correction and de-noise LD PET images. Methods: We trained a modified encoder-decoder U-Net network with standard of care or LD PET images as the input and FD + PVC images by six different PVC methods as the target. These six PVC approaches include geometric transfer matrix (GTM), multi-target correction (MTC), region-based voxel-wise correction (RBV), iterative Yang (IY), reblurred Van-Cittert (RVC), and Richardson-Lucy (RL). The proposed models were evaluated using standard criteria, such as peak signal-to-noise ratio (PSNR), root mean squared error (RMSE), structural similarity index (SSIM), relative bias, and absolute relative bias. Results: Different levels of error were observed for these partial volume correction methods, which were relatively smaller for GTM with a SSIM of 0.63 for LD and 0.29 for FD, IY with an SSIM of 0.63 for LD and 0.67 for FD, RBV with an SSIM of 0.57 for LD and 0.65 for FD, and RVC with an SSIM of 0.89 for LD and 0.94 for FD PVC approaches. However, large quantitative errors were observed for multi-target MTC with an RMSE of 2.71 for LD and 2.45 for FD and RL with an RMSE of 5 for LD and 3.27 for FD PVC approaches. Conclusions: We found that the proposed framework could effectively perform joint de-noising and partial volume correction for PET images with LD and FD input PET data (LD vs. FD). When no magnetic resonance imaging (MRI) images are available, the developed deep learning models could be used for partial volume correction on LD or standard PET-computed tomography (PET-CT) scans as an image quality enhancement technique.
- 1 March 2024
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 14 (3) , 2146-2164
Open AccessDeep learning-based partial volume correction in standard and low-dose positron emission tomography-computed tomography imaging
Background: Positron emission tomography (PET) imaging encounters the obstacle of partial volume effects, arising from its limited intrinsic resolution, giving rise to (I) considerable bias, particularly for structures comparable in size to the point spread function (PSF) of the system; and (II) blurred image edges and blending of textures along the borders. We set out to build a deep learning-based framework for predicting partial volume corrected full-dose (FD + PVC) images from either standard or low-dose (LD) PET images without requiring any anatomical data in order to provide a joint solution for partial volume correction and de-noise LD PET images. Methods: We trained a modified encoder-decoder U-Net network with standard of care or LD PET images as the input and FD + PVC images by six different PVC methods as the target. These six PVC approaches include geometric transfer matrix (GTM), multi-target correction (MTC), region-based voxel-wise correction (RBV), iterative Yang (IY), reblurred Van-Cittert (RVC), and Richardson-Lucy (RL). The proposed models were evaluated using standard criteria, such as peak signal-to-noise ratio (PSNR), root mean squared error (RMSE), structural similarity index (SSIM), relative bias, and absolute relative bias. Results: Different levels of error were observed for these partial volume correction methods, which were relatively smaller for GTM with a SSIM of 0.63 for LD and 0.29 for FD, IY with an SSIM of 0.63 for LD and 0.67 for FD, RBV with an SSIM of 0.57 for LD and 0.65 for FD, and RVC with an SSIM of 0.89 for LD and 0.94 for FD PVC approaches. However, large quantitative errors were observed for multi-target MTC with an RMSE of 2.71 for LD and 2.45 for FD and RL with an RMSE of 5 for LD and 3.27 for FD PVC approaches. Conclusions: We found that the proposed framework could effectively perform joint de-noising and partial volume correction for PET images with LD and FD input PET data (LD vs. FD). When no magnetic resonance imaging (MRI) images are available, the developed deep learning models could be used for partial volume correction on LD or standard PET-computed tomography (PET-CT) scans as an image quality enhancement technique.