Quoc-An Hoang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Quoc-An Hoang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Nghia-Hieu Nguyen
Industrial University of Ho Chi Minh City
2 shared publicationsThanh-Trung Bui
Industrial University of Ho Chi Minh City
2 shared publications- Do Van Dung
Ho Chi Minh City University of Technology and Education, Vietnam
1 shared publication - Huan-Liang Tsai
Department of Computer Science and Information Engineering, Da-Yeh University, Changhua 515006, Taiwan
1 shared publication - Le Phuong Truong
Lac Hong University
1 shared publication
Latest Publications
- Open Access
- 26 March 2023
- Published by Springer Nature
- p. C3
Correction to: Differential Average Temperature Analysis When Applying Pinch Technology to Design Heat Recovery Exchanger of Tube Ice Machine
- 26 March 2023
- Published by Springer Nature
- p. C3
Open AccessCorrection to: Differential Average Temperature Analysis When Applying Pinch Technology to Design Heat Recovery Exchanger of Tube Ice Machine
- 15 December 2022
- Published by Springer Nature
- p. 656-667
Differential Average Temperature Analysis When Applying Pinch Technology to Design Heat Recovery Exchanger of Tube Ice Machine
- 15 December 2022
- Published by Springer Nature
- p. 656-667
Differential Average Temperature Analysis When Applying Pinch Technology to Design Heat Recovery Exchanger of Tube Ice Machine
- Open Access
A Method to Estimate and Analyze the Performance of a Grid-Connected Photovoltaic Power Plant
This paper presents a method to estimate the yield and analyze the performance of a grid-connected photovoltaic (PV) power plant including a rooftop PV system and a solar farm. The yield model was developed based on a commercial PV model in a MATLAB/Simulink environment. A simulation model is built to connect with the PV rooftop system and the solar farm in which their total installed capacities are 0.986 and 30.7 MW, respectively. The simulated and measured final yield results of a rooftop PV system in Vietnam are compared. Additionally, this paper provides a function of reducing the final yield corresponding to different PV operation temperature values. Furthermore, the performance of both a rooftop PV system and a solar farm, in Vietnam, are evaluated as the rated power of 0.986 and 30.7 MWp, respectively. The results also show that their performance is satisfactory, in which the value of the performance ratio (PR) average reaches 70% for the rooftop PV system and 80.45% for the solar farm within a six-month period, in 2019. The PR is also compared with a global PR average from 70% to 80% for a sufficiently well-performed solar system.
Open AccessA Method to Estimate and Analyze the Performance of a Grid-Connected Photovoltaic Power Plant
This paper presents a method to estimate the yield and analyze the performance of a grid-connected photovoltaic (PV) power plant including a rooftop PV system and a solar farm. The yield model was developed based on a commercial PV model in a MATLAB/Simulink environment. A simulation model is built to connect with the PV rooftop system and the solar farm in which their total installed capacities are 0.986 and 30.7 MW, respectively. The simulated and measured final yield results of a rooftop PV system in Vietnam are compared. Additionally, this paper provides a function of reducing the final yield corresponding to different PV operation temperature values. Furthermore, the performance of both a rooftop PV system and a solar farm, in Vietnam, are evaluated as the rated power of 0.986 and 30.7 MWp, respectively. The results also show that their performance is satisfactory, in which the value of the performance ratio (PR) average reaches 70% for the rooftop PV system and 80.45% for the solar farm within a six-month period, in 2019. The PR is also compared with a global PR average from 70% to 80% for a sufficiently well-performed solar system.