TAThore Stig Aunsborg

Thore Stig Aunsborg

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Thore Stig Aunsborg has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Modeling and Stability Analysis of Sustained Oscillations During the Miller Region for Medium-Voltage SiC MOSFET Power Modules

    by Zhixing Yan, Gao Liu, Thore Stig Aunsborg, Benjamin Futtrup Kjærsgaard, Nianzun Qi, Bjørn Rannestad, Michael Møller Bech, Hongbo Zhao, Stig Munk-Nielsen

    Sustained oscillations during the Miller region have been observed in a 10 kV SiC MOSFET power module, which can reduce the robustness or even prevent the proper operation of the module. These oscillations become worse with increased parasitic gate-to-baseplate capacitance. However, the underlying oscillation mechanism involving the parasitic capacitance is still unclear in previous studies. To fill this gap, this article develops the small-signal model considering parasitic capacitances in a half-bridge circuit. Then, the stability analysis of the sustained oscillation in a 10 kV SiC MOSFET power module is conducted. The developed theoretical model agrees well with the experimental results. Finally, possible solutions for mitigating sustained oscillations are provided.


  • Analysis and Mitigation Methods of Gate Oscillation in Paralleled 10 kV SiC MOSFETs

    by Gao Liu, Zhixing Yan, Morten Rahr Nielsen, Thore Stig Aunsborg, Bjørn Rannestad, Hongbo Zhao, Michael Møller Bech, Stig Munk-Nielsen

    Gate oscillations exist in paralleled SiC MOSFETs, which can cause false switching behavior and device damage. This article investigates gate oscillations in paralleled 10 kV SiC mosfets as it is currently one of the bottlenecks for paralleling. During the switching transient, the paralleled SiC mosfets operate in their saturation region, where a closed-loop feedback system is formed between the mosfet transconductance and the parasitic distributions in the circuit. The instability of the closed-loop feedback system is key in describing the gate oscillation mechanism. Therefore, a small signal circuit model of two parallel 10 kV SiC mosfets is used to analyze this mechanism, which takes into account both the parasitic inductances and capacitances of the mosfet, power module, and external connections to predict the impact of different parasitic parameters. From the circuit model, four methods are proposed to mitigate the gate oscillations. Finally, experiments are conducted in a double pulse test platform at 6 kV/20 A, showing a good prediction of the gate oscillations and significant damping by the proposed methods.


  • Impacts of the Bottom Copper Layer of Direct-Bond Copper Substrates on the Partial Discharge Performance in Power Modules

    by Yuan Gao, Kai Yin, Claus Leth Bak, Asger Bjørn Jørgensen, Zichen Zhang, Hongbo Zhao, Stig Munk-Nielsen, Christian Uhrenfeldt, Thore Stig Aunsborg

    This article studies the impacts of the bottom copper layer of direct-bond copper (DBC) substrates on the partial discharge (PD) performance of the power modules. Finite element simulation models of DBC samples with various layouts are developed, and their electric field distributions are compared and analyzed. The results show that by floating the bottom copper layer, applying half of the high voltage, or partially or completely removing the bottom copper layer, the maximum electric field concentrated at the triple point of DBC substrates can be significantly reduced. Multiple DBC samples are manufactured, and their PD performance is experimentally tested. The partial discharge inception voltage (PDIV) can be increased by more than 79% by completely removing the bottom copper layer. Experimental results show good agreement with the simulation analysis and verify the findings. A mimic power module employing the concept of completely removing the bottom-layer copper is made and tested for PD performance under IEC 60270 standard. Compared to the conventional power module structure, the PDIV of the new power module structure can be increased by 63%. The findings in this article can provide guidance and potential strategies to reduce the electric field in encapsulated DBC substrates, which will contribute to optimizing the insulation design of future medium voltage power modules.


  • From Vacuum Tubes to Modern Semiconductors: Opportunities for Industrial Heating Industry

    by Faheem Ahmad, Thore Stig Aunsborg, Asger Bjørn Jørgensen, Stig Munk-Nielsen

    Industrial heating plays a significant role in the modern society. It constitutes about 20% of the global energy consumption. Modern industrial heating plants (especially induction and dielectric heating) uses vacuum tube triode based radio frequency (RF) generator. The vacuum tube RF generator provides an efficiency of 60% or less. This is not optimum, as almost half of the energy is being wasted as heat. Modern semiconductor technology based on wide bandgap (WBG) materials such as silicon carbide (SiC) and gallium nitride (GaN) provides an opportunity to remove the ageing vacuum tube from industrial heating plants. However the industrial heating plants requires high voltage output from the RF generator to deliver high power which has been a technological barrier towards semiconductor implementation in industrial heating industry. In this paper a method is proposed to series connect multiple RF converters to scale-up the output voltage from semiconductor based RF generator. Class-PN is used as RF converter to demonstrate the proposed multi-cell series connection method. Furthermore a controller scheme is presented that allows individual Class-PN RF converter to maintain optimum operation without the need of communication between each cells. For the small-scale prototype three Class-PN cells are operated in multi-cell configuration to boost the DC input of 185 V to peak-peak RF voltage of 1.1 kV at 6.78 MHz. Output power of 856 W at an efficiency of 80% from DC input to RF load is demonstrated.


  • Discovery of Loss Imbalance in SiC Half-Bridge Power Modules – Analysis and Validations

    by Benjamin Futtrup Kjærsgaard, Gao Liu, Thore Stig Aunsborg, Dipen Narendra Dalal, Jannick Kjær Jørgensen, Bjørn Rannestad, Hongbo Zhao, Stig Munk-Nielsen

    It is commonly assumed that power semiconductor switching losses are the same for high-side and low-side devices in a half-bridge power module. However, this article reveals that the high-side SiC mosfet in a medium-voltage power module exhibits over 40% higher switching energy compared with the low-side SiC mosfet . The loss imbalance is attributed to the parasitic high-side gate capacitance in the power module, which contributes to the equivalent high-side Miller capacitance. A physics-based switching energy dissipation model is, therefore, proposed, distinguishing between low-side and high-side switching energy dissipation. Double pulse testing demonstrates that high-side switching energy dissipation increases by 5 mJ per 2.5-pF increment in the equivalent Miller capacitance, aligning closely with the analytically calculated increase of 6 mJ per 2.5 pF. Continuous power module testing shows a 10 $\mathrm{^{\circ }}$ C increase in high-side junction temperature. The findings from this article offer crucial insights into research, design, and manufacturing of half-bridge modules enabled by SiC mosfet s.


  • Top Cited Papers
    Open Access

    Parasitic Capacitive Couplings in Medium Voltage Power Electronic Systems: An Overview

    by Benjamin Futtrup Kjærsgaard, Gao Liu, Morten Rahr Nielsen, Rui Wang, Dipen Narendra Dalal, Thore Stig Aunsborg, Jannick Kjær Jørgensen, Zhixing Yan, Jonas Jacobsen, Rui Wu, et al.

    Recent developments within the field of medium voltage wide-bandgap semiconductor devices are drawing attention from both researchers and industries due to the demanding requirements for more efficient high-power energy conversion. The rapid development has entailed an increased awareness of the negative impact of the increased rate of change in voltage, d v /d t , and its derived issues caused by the inevitable parasitic capacitive couplings. This article is dedicated to present an overview of the parasitic capacitive couplings in high-power medium voltage power electronic converter systems, using an example reference system enabled by medium voltage SiC mosfet s. The definitions of capacitive couplings are presented and the impacts raised by parasitic capacitive couplings are reviewed. In addition, the similarities of different capacitive couplings introduced by components in practical medium voltage systems are presented and summarized. Lastly, the challenges and future work with respect to parasitic capacitive couplings in medium voltage power electronics converter systems are shared from the authors' perspective.


  • Open Access

    Development of a current source resonant inverter for high current MHz induction heating

    by Thore S. Aunsborg, Sune Bro Duun, Stig Munk‐Nielsen, Christian Uhrenfeldt

    High frequency industrial induction heating processes typically employ resonant inverters to reach high efficiency at high power levels. Advancements in wide band gap (WBG) device technology has made it feasible to push the possible frequency of these processes into the MHz regime using solid state technology. Several topologies can be applied, each with advantages and drawbacks. This paper presents a current source resonant inverter (CSRI) employing a custom designed power module utilizing 1700V SiC MOSFETs for MHz operation of a high-Q resonant tank for induction heating, which presents new challenges in the inverter module design. An integrated gate driver structure is demonstrated driving four MOSFETs in parallel in MHz operation. Theoretical analysis predicts substantial parasitic influence on inverter operation, and thus an inverter is constructed to provide experimental verification of MHz operation, while the challenges associated with high frequency CSRI operation are discussed. In the experimental inverter setup, the fabricated power module achieves > 90 % efficiency for a calculated reactive power of 170 kVA and 2.3 kW output power during unloaded operation, validating the inverter design for extension to higher power loaded operation.