Elif Çelebi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Elif Çelebi has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Özlem Görmez
Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Suleyman Demirel University, Isparta, Turkey
3 shared publications - Gürkan Ünsal
Western University
2 shared publications - Hikmet Orhan
Department of Basic Medical Sciences, Division of Biostatistics and Medical Informatics, Faculty of Medicine, Süleyman Demirel University, Isparta, Turkey
2 shared publications - Melisa Öçbe
Faculty of Dentistry, Department of Oral and Maxillofacial Radiology, Kocaeli Health and Technology University, Kocaeli, Türkiye
2 shared publications - Atalay Doğru
Department of rheumatology, Süleyman Demirel University, Isparta, Turkey
1 shared publication - Ayse Rabia Isik
Isparta Oral and Dental Health Center, Isparta, Turkey
1 shared publication
Latest Publications
- Open Access
- 20 February 2026
- Published by Journal of Medicine and Palliative Care in Journal of Medicine and Palliative Care
- Vol. 7 (1) , 121-127
Evaluation of submandibular fossa depth and morphology using cone-beam computed tomography: a correlation with alveolar bone height and edentulism
Aims: To evaluate the morphology of the submandibular fossa (SF) using cone-beam computed tomography (CBCT) and to determine its relationship with alveolar bone dimensions and edentulism.Methods: A total of 116 CBCT scans of patients aged 18 years or older were retrospectively analyzed. SF height, SF depth, lingual concavity angle, alveolar bone height, and alveolar bone width were measured bilaterally on coronal CBCT sections at the site of maximum SF depth. Comparisons between sides, sexes, and dentate versus edentulous regions were performed, and correlations between age, SF parameters, and alveolar bone dimensions were analyzed. Results: Linear dimensions of the SF and alveolar bone demonstrated bilateral symmetry, whereas the lingual concavity angle was significantly greater on the left side (p
- 20 February 2026
- Published by Journal of Medicine and Palliative Care in Journal of Medicine and Palliative Care
- Vol. 7 (1) , 121-127
Open AccessEvaluation of submandibular fossa depth and morphology using cone-beam computed tomography: a correlation with alveolar bone height and edentulism
Aims: To evaluate the morphology of the submandibular fossa (SF) using cone-beam computed tomography (CBCT) and to determine its relationship with alveolar bone dimensions and edentulism.Methods: A total of 116 CBCT scans of patients aged 18 years or older were retrospectively analyzed. SF height, SF depth, lingual concavity angle, alveolar bone height, and alveolar bone width were measured bilaterally on coronal CBCT sections at the site of maximum SF depth. Comparisons between sides, sexes, and dentate versus edentulous regions were performed, and correlations between age, SF parameters, and alveolar bone dimensions were analyzed. Results: Linear dimensions of the SF and alveolar bone demonstrated bilateral symmetry, whereas the lingual concavity angle was significantly greater on the left side (p
- Open Access
- 12 January 2026
- Published by LookUs Bilisim A.S. in Medical Records
- No. 1
Prevalence and Sonographic Features of Incidental Thyroid Nodules in Maxillofacial Radiology: An EU-TIRADS-Based Risk Assessment
Aim: Incidental thyroid nodules (ITNs) are frequently discovered during imaging for non-thyroid-related reasons, with ultrasonography (US) serving as a key tool for their detection and risk assessment. This study aims to determine the prevalence and sonographic characteristics of ITNs in patients undergoing head and neck ultrasonography for non-thyroidal indications at a maxillofacial radiology clinic, using the European Thyroid Imaging Reporting and Data System (EU-TIRADS) for risk stratification.Material and Methods: Patients referred for head and neck ultrasonography for indications unrelated to thyroid pathology were included in this study. Patients with known thyroid disease, palpable thyroid masses, prior thyroid surgery, or head and neck radiotherapy were excluded. Thyroid nodule characteristics, including size, composition, echogenicity, margin, shape, and vascularity, were evaluated. Risk stratification was performed using the EU-TIRADS system, and nodules with suspicious features were referred forfurther evaluation, including fine-needle aspiration cytology.Results: A total of 170 patients aged between 17 and 72 years (mean age: 29.35 years) were evaluated. Incidental thyroid nodules were identified in 49 patients (28.8%). Nodules were present in 24.29% of males (n=70) and 32% of females (n=100). Among the patients with nodules, 3 patients (6.12%) were diagnosed with papillary thyroid carcinoma (PTC), and 13 patients (7.7%) were referred for endocrinology consultation due to thyroiditis, hypoplasia, or hyperplasia.Conclusion: The findings underscore the importance of opportunistic thyroid evaluation in patients undergoing head and neck ultrasonography for non-thyroidal reasons. With a 28.8% prevalence of incidental thyroid nodules, early detection through such opportunistic screening may facilitate timely management of suspicious lesions.
- 12 January 2026
- Published by LookUs Bilisim A.S. in Medical Records
- No. 1
Open AccessPrevalence and Sonographic Features of Incidental Thyroid Nodules in Maxillofacial Radiology: An EU-TIRADS-Based Risk Assessment
Aim: Incidental thyroid nodules (ITNs) are frequently discovered during imaging for non-thyroid-related reasons, with ultrasonography (US) serving as a key tool for their detection and risk assessment. This study aims to determine the prevalence and sonographic characteristics of ITNs in patients undergoing head and neck ultrasonography for non-thyroidal indications at a maxillofacial radiology clinic, using the European Thyroid Imaging Reporting and Data System (EU-TIRADS) for risk stratification.Material and Methods: Patients referred for head and neck ultrasonography for indications unrelated to thyroid pathology were included in this study. Patients with known thyroid disease, palpable thyroid masses, prior thyroid surgery, or head and neck radiotherapy were excluded. Thyroid nodule characteristics, including size, composition, echogenicity, margin, shape, and vascularity, were evaluated. Risk stratification was performed using the EU-TIRADS system, and nodules with suspicious features were referred forfurther evaluation, including fine-needle aspiration cytology.Results: A total of 170 patients aged between 17 and 72 years (mean age: 29.35 years) were evaluated. Incidental thyroid nodules were identified in 49 patients (28.8%). Nodules were present in 24.29% of males (n=70) and 32% of females (n=100). Among the patients with nodules, 3 patients (6.12%) were diagnosed with papillary thyroid carcinoma (PTC), and 13 patients (7.7%) were referred for endocrinology consultation due to thyroiditis, hypoplasia, or hyperplasia.Conclusion: The findings underscore the importance of opportunistic thyroid evaluation in patients undergoing head and neck ultrasonography for non-thyroidal reasons. With a 28.8% prevalence of incidental thyroid nodules, early detection through such opportunistic screening may facilitate timely management of suspicious lesions.
- 21 November 2025
- Published by Wiley in Australian Dental Journal
- Vol. 71 (1) , 68-73
Radiopacity Evaluation of 3D Printed Permanent Crown Restoration Materials
Background: To analyze the radiopacity of three commercially available 3D printing resins, which are currently used for permanent crowns. Methods: Samples were fabricated using Saremco Print Crowntec, VarseoSmile Crown Plus, and Duraprint at 0.5, 1, and 1.5 mm thicknesses. Radiographs were taken alongside a 1‐mm tooth section and aluminum step wedge using a photostimulable phosphor system at 60 kVp, 7 mA, 0.25 s, and a 30 cm source‐to‐object distance. Mean grayscale values were analyzed in ImageJ to calculate mm Al values. Statistical analyses included one‐way ANOVA and Tukey HSD tests ( p = 0.05). Results: The radiopacity of all tested materials was statistically significantly lower than that of enamel (2.30 ± 0.07 mmAl). Except for the 1.5 mm thick Saremco Print Crowntec and VarseoSmile Crown Plus groups, all of them showed statistically significantly lower radiopacity than that of the dentine (1.27 ± 0.08 mmAl). Duraprint showed the lowest radiopacity values among all groups, and didn't show a statistically significant difference in various thicknesses. Conclusions: The related 3D printing resins might not achieve sufficient radiopacity, particularly in thin restorations. In Duraprint restorations, distinguishing the natural tissues, restoration or caries would be difficult due to the lack of radiopacity.
- 21 November 2025
- Published by Wiley in Australian Dental Journal
- Vol. 71 (1) , 68-73
Radiopacity Evaluation of 3D Printed Permanent Crown Restoration Materials
Background: To analyze the radiopacity of three commercially available 3D printing resins, which are currently used for permanent crowns. Methods: Samples were fabricated using Saremco Print Crowntec, VarseoSmile Crown Plus, and Duraprint at 0.5, 1, and 1.5 mm thicknesses. Radiographs were taken alongside a 1‐mm tooth section and aluminum step wedge using a photostimulable phosphor system at 60 kVp, 7 mA, 0.25 s, and a 30 cm source‐to‐object distance. Mean grayscale values were analyzed in ImageJ to calculate mm Al values. Statistical analyses included one‐way ANOVA and Tukey HSD tests ( p = 0.05). Results: The radiopacity of all tested materials was statistically significantly lower than that of enamel (2.30 ± 0.07 mmAl). Except for the 1.5 mm thick Saremco Print Crowntec and VarseoSmile Crown Plus groups, all of them showed statistically significantly lower radiopacity than that of the dentine (1.27 ± 0.08 mmAl). Duraprint showed the lowest radiopacity values among all groups, and didn't show a statistically significant difference in various thicknesses. Conclusions: The related 3D printing resins might not achieve sufficient radiopacity, particularly in thin restorations. In Duraprint restorations, distinguishing the natural tissues, restoration or caries would be difficult due to the lack of radiopacity.
- Open Access
- 25 October 2025
- Published by Journal of Health Sciences and Medicine in Journal of Health Sciences and Medicine
- Vol. 8 (6) , 1011-1017
Evaluation of sex estimation through mandibular morphometric measurements on cone-beam computed tomography images
Aims: Sex estimation of unidentified human remains is a critical component of forensic investigations. Among facial bones, the mandible is the most robust and resilient structure, making it a valuable element for personal identification. The aim of this study was to evaluate the potential of mandibular metric parameters-obtained via cone-beam computed tomography (CBCT)-for determining sex. Methods: CBCT scans of 199 individuals (72 males and 127 females), aged between 18 and 81 years, were retrospectively analyzed. Nine mandibular parameters were measured including the mandibular angle, coronoid and condylar lengths, minimal ramus breadth, and mandibular length, along with bigonial breadth, bicondylar breadth, bimental breadth, and symphyseal height. Statistical analyses included repeated measures ANOVA, independent samples t-test, Pearson correlation, and discriminant function analysis. Results: Males consistently exhibited higher mean values across all parameters, except for the mandibular angle, which was slightly greater in females (female: 119.33±0.56; male: 118.79±0.75) but not statistically significant (p=0.566). The most influential variables, based on structure matrix coefficients, were left coronoid length (0.791), right coronoid length (0.649), left condylar length (0.492), and bigonial breadth (0.477). Discriminant function analysis yielded a high overall sex classification accuracy of 91.5%. Conclusion: The mandible demonstrated high discriminative power, with CBCT-derived measurements providing accurate and reproducible indicators of sexual dimorphism. These findings underscore the utility of mandibular morphometry as a reliable tool for sex estimation in forensic practice.
- 25 October 2025
- Published by Journal of Health Sciences and Medicine in Journal of Health Sciences and Medicine
- Vol. 8 (6) , 1011-1017
Open AccessEvaluation of sex estimation through mandibular morphometric measurements on cone-beam computed tomography images
Aims: Sex estimation of unidentified human remains is a critical component of forensic investigations. Among facial bones, the mandible is the most robust and resilient structure, making it a valuable element for personal identification. The aim of this study was to evaluate the potential of mandibular metric parameters-obtained via cone-beam computed tomography (CBCT)-for determining sex. Methods: CBCT scans of 199 individuals (72 males and 127 females), aged between 18 and 81 years, were retrospectively analyzed. Nine mandibular parameters were measured including the mandibular angle, coronoid and condylar lengths, minimal ramus breadth, and mandibular length, along with bigonial breadth, bicondylar breadth, bimental breadth, and symphyseal height. Statistical analyses included repeated measures ANOVA, independent samples t-test, Pearson correlation, and discriminant function analysis. Results: Males consistently exhibited higher mean values across all parameters, except for the mandibular angle, which was slightly greater in females (female: 119.33±0.56; male: 118.79±0.75) but not statistically significant (p=0.566). The most influential variables, based on structure matrix coefficients, were left coronoid length (0.791), right coronoid length (0.649), left condylar length (0.492), and bigonial breadth (0.477). Discriminant function analysis yielded a high overall sex classification accuracy of 91.5%. Conclusion: The mandible demonstrated high discriminative power, with CBCT-derived measurements providing accurate and reproducible indicators of sexual dimorphism. These findings underscore the utility of mandibular morphometry as a reliable tool for sex estimation in forensic practice.
- 17 September 2025
- Published by Springer Nature in Oral Radiology
- Vol. 42 (2) , 333-340
U-net-based segmentation of foreign bodies and ghost images in panoramic radiographs
Objectives This study aimed to develop and evaluate a deep convolutional neural network (CNN) model for the automatic segmentation of foreign bodies and ghost images in panoramic radiographs (PRs), which can complicate diagnostic interpretation. Methods A dataset of 11,226 PRs from four devices was annotated by two radiologists using the Computer Vision Annotation Tool. A U-Net-based CNN model was trained and evaluated using Intersection over Union (IoU), Dice coefficient, accuracy, precision, recall, and F1 score. Results For foreign body segmentation, the model achieved validation Dice and IoU scores of 0.9439 and 0.9043, and test scores of 0.9657 and 0.9371. For ghost image segmentation, validation Dice and IoU were 0.8234 and 0.7388, with test scores of 0.8749 and 0.8145. Overall test accuracy exceeded 0.999. Conclusions The AI model showed high accuracy in segmenting foreign bodies and ghost images in PRs, indicating its potential to assist radiologists. Further clinical validation is recommended.
- 17 September 2025
- Published by Springer Nature in Oral Radiology
- Vol. 42 (2) , 333-340
U-net-based segmentation of foreign bodies and ghost images in panoramic radiographs
Objectives This study aimed to develop and evaluate a deep convolutional neural network (CNN) model for the automatic segmentation of foreign bodies and ghost images in panoramic radiographs (PRs), which can complicate diagnostic interpretation. Methods A dataset of 11,226 PRs from four devices was annotated by two radiologists using the Computer Vision Annotation Tool. A U-Net-based CNN model was trained and evaluated using Intersection over Union (IoU), Dice coefficient, accuracy, precision, recall, and F1 score. Results For foreign body segmentation, the model achieved validation Dice and IoU scores of 0.9439 and 0.9043, and test scores of 0.9657 and 0.9371. For ghost image segmentation, validation Dice and IoU were 0.8234 and 0.7388, with test scores of 0.8749 and 0.8145. Overall test accuracy exceeded 0.999. Conclusions The AI model showed high accuracy in segmenting foreign bodies and ghost images in PRs, indicating its potential to assist radiologists. Further clinical validation is recommended.
- Open Access
- 2 July 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-9
Assessment of periodontal inflammatory burden and radiomorphometric indices in geriatric individuals in Turkey: a retrospective study
Oral health in older adults is frequently compromised due to a higher prevalence of periodontal disease, tooth loss, and systemic conditions such as osteoporosis. Altough the association between periodontitis and osteoporosis has been explored, further research is warranted to assess the periodontal inflammatory burden in the context of bone health. This study hypothesised that periodontal inflammatory burden, measured by Periodontal Inflamed Surface Area (PISA), may contribute to osteoporotic changes in the mandible. The objective was to evaluate the relationship between periodontal status and mandibular osteoporotic changes by assessing inflammatory burden via PISA and panoramic radiomorphometric indices in geriatric individuals. This retrospective study included 149 patients aged ≥ 65 years. Participants were grouped by periodontal health, and PISA values were calculated. Panoramic radiographs were analysed to assess mandibular bone quality using the Mental Index (MI), Panoramic Mandibular Index (PMI), and Mandibular Cortical Index (MCI). Statistical analyses evaluated the associations between periodontal status, PISA values, and radiomorphometric indices. The mean participant age was 70 ± 4 years. There were no significant differences in MI, PMI, or MCI among periodontal health groups (p > 0.05). However, PISA values showed substantial correlations with MI (p = 0.024), PMI (p = 0.005), and MCI (p = 0.04), indicating a potential association between periodontal inflammation and mandibular bone structure. To the best of our knowledge, this is the first study to correlate PISA values with mandibular osteoporotic changes. While the periodontitis stage was not significantly associated with radiomorphometric indices, PISA was. These findings suggest that inflammatory burden, rather than disease severity alone, may influence mandibular bone characteristics. PISA may serve as a valuable indicator of inflammation-related bone changes.
- 2 July 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-9
Open AccessAssessment of periodontal inflammatory burden and radiomorphometric indices in geriatric individuals in Turkey: a retrospective study
Oral health in older adults is frequently compromised due to a higher prevalence of periodontal disease, tooth loss, and systemic conditions such as osteoporosis. Altough the association between periodontitis and osteoporosis has been explored, further research is warranted to assess the periodontal inflammatory burden in the context of bone health. This study hypothesised that periodontal inflammatory burden, measured by Periodontal Inflamed Surface Area (PISA), may contribute to osteoporotic changes in the mandible. The objective was to evaluate the relationship between periodontal status and mandibular osteoporotic changes by assessing inflammatory burden via PISA and panoramic radiomorphometric indices in geriatric individuals. This retrospective study included 149 patients aged ≥ 65 years. Participants were grouped by periodontal health, and PISA values were calculated. Panoramic radiographs were analysed to assess mandibular bone quality using the Mental Index (MI), Panoramic Mandibular Index (PMI), and Mandibular Cortical Index (MCI). Statistical analyses evaluated the associations between periodontal status, PISA values, and radiomorphometric indices. The mean participant age was 70 ± 4 years. There were no significant differences in MI, PMI, or MCI among periodontal health groups (p > 0.05). However, PISA values showed substantial correlations with MI (p = 0.024), PMI (p = 0.005), and MCI (p = 0.04), indicating a potential association between periodontal inflammation and mandibular bone structure. To the best of our knowledge, this is the first study to correlate PISA values with mandibular osteoporotic changes. While the periodontitis stage was not significantly associated with radiomorphometric indices, PISA was. These findings suggest that inflammatory burden, rather than disease severity alone, may influence mandibular bone characteristics. PISA may serve as a valuable indicator of inflammation-related bone changes.
- Open Access
- 1 June 2025
- Published by Bentham Science Publishers Ltd. in Current Medical Imaging
- Vol. 21, 1-7
The Role of Ultrasound Imaging in Evaluating Eagle’s Syndrome: A Case Report
Background: Eagle’s Syndrome is a unilateral or bilateral elongation of the styloid process or calcified stylohyoid ligament, along with other symptoms, such as dysphagia, facial pain, globus sensation, and headache. Stylocarotid artery syndrome is a specific type of Eagle’s syndrome that causes various clinical symptoms due to pressure on adjacent anatomical structures. Case Presentation: This study presents a case of a 57-year-old female patient with a complaint of facial pain, head and neck discomfort, globus sensation, difficulty swallowing, and dizziness during head rotation. The patient was diagnosed with a bilateral elongated styloid process through panoramic radiography and cone beam computed tomography. Due to suspicion of stylocarotid artery syndrome, further evaluation was conducted using ultrasound imaging. Conclusion: Bilateral elongated styloid processes can contribute to Stylocarotid Artery Syndrome (SAS). Ultrasound imaging, specifically B-mode and pulsed wave Doppler, proved to be valuable in detecting real-time vascular flow dynamics in extracranial vessels, highlighting its auxiliary role in the assessment of stylocarotid artery syndrome.
- 1 June 2025
- Published by Bentham Science Publishers Ltd. in Current Medical Imaging
- Vol. 21, 1-7
Open AccessThe Role of Ultrasound Imaging in Evaluating Eagle’s Syndrome: A Case Report
Background: Eagle’s Syndrome is a unilateral or bilateral elongation of the styloid process or calcified stylohyoid ligament, along with other symptoms, such as dysphagia, facial pain, globus sensation, and headache. Stylocarotid artery syndrome is a specific type of Eagle’s syndrome that causes various clinical symptoms due to pressure on adjacent anatomical structures. Case Presentation: This study presents a case of a 57-year-old female patient with a complaint of facial pain, head and neck discomfort, globus sensation, difficulty swallowing, and dizziness during head rotation. The patient was diagnosed with a bilateral elongated styloid process through panoramic radiography and cone beam computed tomography. Due to suspicion of stylocarotid artery syndrome, further evaluation was conducted using ultrasound imaging. Conclusion: Bilateral elongated styloid processes can contribute to Stylocarotid Artery Syndrome (SAS). Ultrasound imaging, specifically B-mode and pulsed wave Doppler, proved to be valuable in detecting real-time vascular flow dynamics in extracranial vessels, highlighting its auxiliary role in the assessment of stylocarotid artery syndrome.
- Open Access
- 29 May 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-8
Exploring the potential of interdental brush in oral cytology: a pilot study on sampling efficiency
With the renewed interest in brush biopsies, particularly for screening oral potentially malignant disorders and cancers, understanding the efficacy of available brush types in oral cytology is crucial. This study aims to compare the effectiveness of interdental brush sampling with commonly used cytology brushes in oral cytology evaluation. The study design was an observational clinical study. Brush biopsies were collected from the buccal mucosa of 99 healthy volunteers using an Interdental Brush- TePe Original Interdental Brush (TePe, Malmö, Sweden) (Cell sampling-Interdental Brush (CSIB)), Cytobrush Plus GT (Medscand Medical AB, Sweden) (Cell sampling device 1 (CSD1)), and CervexBrush (Rovers, Oss, Netherlands) (Cell sampling device 2 (CSD2)). Samples were evaluated for cellularity, depth of the epithelial layer, and cellular integrity. Results were compared between brush types using the Friedman test, and multiple comparisons were examined using the Dunn test. The significance level was set at p < 0.05. Of the 99 cases, 59.6% were female and 40.4% were male, with a prevalence of smoking and alcohol consumption at 43.4%. The mean age was 24.3 years (± 4.5). There were no significant differences in cellularity between the brush types (p = 0.205). Mild cellularity was observed at rates of 3%, 9.1%, and 9.1% for CSD1, CSIB, and CSD2, respectively. Parabasal/basal layer cells were detected in 1% of samples collected with CSD1 and 4% with CSD2, while CSIB samples contained only superficial/intermediate cells. CSIB produced an inadequate integrity rate of 30.3%, whereas neither CSD2 nor CSD1 yielded samples with inadequate integrity. Interdental brushes may have potential as accessible and practical tools for chairside cytological screening. The CSIB obtained high-cellularity samples; however, it demonstrated low scores in cellular integrity. Future oral cytological studies may explore the modifications in interdental brush design to improve its potential in sampling for cell preservation and integrity.
- 29 May 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-8
Open AccessExploring the potential of interdental brush in oral cytology: a pilot study on sampling efficiency
With the renewed interest in brush biopsies, particularly for screening oral potentially malignant disorders and cancers, understanding the efficacy of available brush types in oral cytology is crucial. This study aims to compare the effectiveness of interdental brush sampling with commonly used cytology brushes in oral cytology evaluation. The study design was an observational clinical study. Brush biopsies were collected from the buccal mucosa of 99 healthy volunteers using an Interdental Brush- TePe Original Interdental Brush (TePe, Malmö, Sweden) (Cell sampling-Interdental Brush (CSIB)), Cytobrush Plus GT (Medscand Medical AB, Sweden) (Cell sampling device 1 (CSD1)), and CervexBrush (Rovers, Oss, Netherlands) (Cell sampling device 2 (CSD2)). Samples were evaluated for cellularity, depth of the epithelial layer, and cellular integrity. Results were compared between brush types using the Friedman test, and multiple comparisons were examined using the Dunn test. The significance level was set at p < 0.05. Of the 99 cases, 59.6% were female and 40.4% were male, with a prevalence of smoking and alcohol consumption at 43.4%. The mean age was 24.3 years (± 4.5). There were no significant differences in cellularity between the brush types (p = 0.205). Mild cellularity was observed at rates of 3%, 9.1%, and 9.1% for CSD1, CSIB, and CSD2, respectively. Parabasal/basal layer cells were detected in 1% of samples collected with CSD1 and 4% with CSD2, while CSIB samples contained only superficial/intermediate cells. CSIB produced an inadequate integrity rate of 30.3%, whereas neither CSD2 nor CSD1 yielded samples with inadequate integrity. Interdental brushes may have potential as accessible and practical tools for chairside cytological screening. The CSIB obtained high-cellularity samples; however, it demonstrated low scores in cellular integrity. Future oral cytological studies may explore the modifications in interdental brush design to improve its potential in sampling for cell preservation and integrity.
- Open Access
- 27 February 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-9
An overlooked connection: oral health status in patients with chronic diseases
Oral and systemic health are closely linked. Chronic diseases like diabetes mellitus, cardiovascular diseases, and hypertension increase the risk of dental caries, periodontal disease and tooth loss. Moreover, poor oral health can worsen the status of systemic diseases. Despite this, oral health is often overlooked in chronic disease management. This study aimed to evaluate the oral health status of patients with chronic diseases (PWCD) compared to healthy controls using DIMF-T and DMF-S indices. This retrospective study included 205 participants (106 PWCD and 99 healthy controls) attending the Oral Diagnosis & Radiology outpatient clinic at Bahçeşehir University Dental Hospital. Comprehensive intraoral and radiological examinations assessed caries lesions, missing teeth, filled teeth, periodontal disease, denture usage, and the prevalence of apical osteitis, soft tissue lesions, and intraosseous lesions. Oral health status was quantified using DIMF-T and DMF-S indices. Statistical analyses were conducted to identify differences between groups. The study group (PWCD) exhibited significantly higher median values for missing teeth (MT), decayed surfaces (DS), missing surfaces (MS), DIMF-T, and DMF-S indices compared to the control group (p < 0.001). Chronic periodontitis was more prevalent in PWCD (76.42%) than in controls (45.45%), while gingivitis was more common in the control group (52.53%, p < 0.001). Medication use for systemic diseases was strongly associated with poor oral health outcomes (p < 0.001). However, no significant differences were observed between the groups for decayed teeth (DT), hopeless teeth (IT), or filled teeth (FT). PWCD demonstrated worse oral health outcomes compared to healthy controls, highlighting the need for integrated oral and systemic healthcare strategies. Dental professionals should be careful in identifying oral conditions that may signal underlying systemic diseases. Future research should explore the integration of oral health evaluations into routine medical screenings and examine the global practices of oral health management in PWCD.
- 27 February 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-9
Open AccessAn overlooked connection: oral health status in patients with chronic diseases
Oral and systemic health are closely linked. Chronic diseases like diabetes mellitus, cardiovascular diseases, and hypertension increase the risk of dental caries, periodontal disease and tooth loss. Moreover, poor oral health can worsen the status of systemic diseases. Despite this, oral health is often overlooked in chronic disease management. This study aimed to evaluate the oral health status of patients with chronic diseases (PWCD) compared to healthy controls using DIMF-T and DMF-S indices. This retrospective study included 205 participants (106 PWCD and 99 healthy controls) attending the Oral Diagnosis & Radiology outpatient clinic at Bahçeşehir University Dental Hospital. Comprehensive intraoral and radiological examinations assessed caries lesions, missing teeth, filled teeth, periodontal disease, denture usage, and the prevalence of apical osteitis, soft tissue lesions, and intraosseous lesions. Oral health status was quantified using DIMF-T and DMF-S indices. Statistical analyses were conducted to identify differences between groups. The study group (PWCD) exhibited significantly higher median values for missing teeth (MT), decayed surfaces (DS), missing surfaces (MS), DIMF-T, and DMF-S indices compared to the control group (p < 0.001). Chronic periodontitis was more prevalent in PWCD (76.42%) than in controls (45.45%), while gingivitis was more common in the control group (52.53%, p < 0.001). Medication use for systemic diseases was strongly associated with poor oral health outcomes (p < 0.001). However, no significant differences were observed between the groups for decayed teeth (DT), hopeless teeth (IT), or filled teeth (FT). PWCD demonstrated worse oral health outcomes compared to healthy controls, highlighting the need for integrated oral and systemic healthcare strategies. Dental professionals should be careful in identifying oral conditions that may signal underlying systemic diseases. Future research should explore the integration of oral health evaluations into routine medical screenings and examine the global practices of oral health management in PWCD.
- Open Access
- 25 March 2024
- Published by Journal of Health Sciences and Medicine in Journal of Health Sciences and Medicine
- Vol. 7 (2) , 192-198
Radiopacity evaluations of the novel calcium-silicate and glass-Ionomer-based materials
Aims: Radiopacity is a crucial property for a liner or base material, and these materials should provide an optimal contrast for detecting secondary caries in radiographic examinations. The purpose of this study was to assess the radiopacity characteristics of four calcium-silicate-based and two glass-ionomer-based materials used as a liner or base in direct or indirect vital pulp therapy. Methods: A total of 60 cylindrical-shaped and 1 mm thick specimens were prepared from a calcium-silicate (Biodentine, Septodont), a calcium-silicate (MTA, Angelus), a light-cured resin-modified calcium silicate (TheraCal LC, Bisco), a dual-cured resin-modified calcium silicate (TheraCal PT, Bisco), a glass hybrid glass-ionomer (Equia Forte HT, GC), and a resin-modified glass ionomer (Glass Liner, Wp Dental) material (n=10). Digital radiographic images of the specimens, a molar tooth section with 1 mm thickness, and an aluminum step wedge were obtained by a digital radiography system (Heliodent Plus, Dentsply Sirona) with 60 kV voltage, 7 mA current, and 0.25 seconds exposure time. The mean gray values (MGV) of digital images were determined using the ImageJ software program (National Institute of Health, Bethesda, MD, USA). Kruskal-Wallis and Mann-Whitney tests (p Biodentine>Equia Forte HT>Theracal PT>Theracal LC>Glass Liner, respectively. All the tested liner or base materials exhibited significantly greater radiopacity values when compared to those of dentin (p<0.05). MTA has statistically significantly higher, Biodentine, Theracal PT, Theracal LC, and Glass Liner have statistically significantly lower radiopacity values than enamel (p<0.05). Conclusion: All the restorative materials tested exhibited higher radiopacity than dentin, with ThereCal LC and Glass Liner displaying lower radiopacity than enamel, ThereCal PT, Biodentine, and Equia showing equivalent radiopacity to enamel, and MTA demonstrating higher radiopacity than enamel.
- 25 March 2024
- Published by Journal of Health Sciences and Medicine in Journal of Health Sciences and Medicine
- Vol. 7 (2) , 192-198
Open AccessRadiopacity evaluations of the novel calcium-silicate and glass-Ionomer-based materials
Aims: Radiopacity is a crucial property for a liner or base material, and these materials should provide an optimal contrast for detecting secondary caries in radiographic examinations. The purpose of this study was to assess the radiopacity characteristics of four calcium-silicate-based and two glass-ionomer-based materials used as a liner or base in direct or indirect vital pulp therapy. Methods: A total of 60 cylindrical-shaped and 1 mm thick specimens were prepared from a calcium-silicate (Biodentine, Septodont), a calcium-silicate (MTA, Angelus), a light-cured resin-modified calcium silicate (TheraCal LC, Bisco), a dual-cured resin-modified calcium silicate (TheraCal PT, Bisco), a glass hybrid glass-ionomer (Equia Forte HT, GC), and a resin-modified glass ionomer (Glass Liner, Wp Dental) material (n=10). Digital radiographic images of the specimens, a molar tooth section with 1 mm thickness, and an aluminum step wedge were obtained by a digital radiography system (Heliodent Plus, Dentsply Sirona) with 60 kV voltage, 7 mA current, and 0.25 seconds exposure time. The mean gray values (MGV) of digital images were determined using the ImageJ software program (National Institute of Health, Bethesda, MD, USA). Kruskal-Wallis and Mann-Whitney tests (p Biodentine>Equia Forte HT>Theracal PT>Theracal LC>Glass Liner, respectively. All the tested liner or base materials exhibited significantly greater radiopacity values when compared to those of dentin (p<0.05). MTA has statistically significantly higher, Biodentine, Theracal PT, Theracal LC, and Glass Liner have statistically significantly lower radiopacity values than enamel (p<0.05). Conclusion: All the restorative materials tested exhibited higher radiopacity than dentin, with ThereCal LC and Glass Liner displaying lower radiopacity than enamel, ThereCal PT, Biodentine, and Equia showing equivalent radiopacity to enamel, and MTA demonstrating higher radiopacity than enamel.