Muhammad Tanweer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Muhammad Tanweer has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Raimo Sepponen
Department of Electronics and Nanoengineering, Aalto University, Espoo, Finland
4 shared publications- Kari Halonen
Department of Electronics and Nanoengineering, Aalto University, Espoo, Finland
3 shared publications - Dipesh C. Monga
Department of Electronics and Nanoengineering, Aalto University, Espoo, Finland
2 shared publications - Ihsan Oguz Tanzer
Department of Electronics and Nanoengineering, Aalto University, Espoo, Finland
2 shared publications - Liam Gillan
VTT Technical Research Centre of Finland Ltd, Espoo, Finland
2 shared publications - Gaurav Singh
Department of Electronics and Nanoengineering, Aalto University, Espoo, Finland
1 shared publication
Latest Publications
- Open Access
- 26 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 12 (15) , 31575-31587
Urine-Powered Batteryless Sensor Node With Printed Harvesters and Sensors for Smart Diapers
As the global population ages, caregivers encounter significant challenges in monitoring wet diapers and assessing the volumes of voided fluids in adult incontinence products. Recent advancements in smart-diaper technology address these issues, but challenges persist with integrating electronics, frequent removal and reapplication, and managing batteries. This study presents a batteryless urine-powered IoT sensor node using printed energy harvesters (EH) and capacitive sensors integrated with an ultralow-power integrated circuit for disposable smart diapers. Coplanar capacitive sensors and electrochemical EH are printed on the flexible substrate using environment-friendly materials. An ultralow power frontend interface is developed, which is powered by the harvested energy from urine. Laboratory measurements validate the functionality of on-chip electronics and the performance of in-diaper sensors and EH. The system demonstrates effective energy harvesting by maintaining a stable regulated voltage of 1.1 V with urine volumes of 90 ml or more, powering the front-end electronics continuously for 6 h. The proposed system successfully demonstrated the detection of multiple urination events in the diaper and quantified the voided volume as low as 30 ml. The results demonstrated in this work pave the way for cost-effective, disposable, and environmentally friendly solutions for smart diapers, enhancing both efficiency and comfort for caregivers and elderly individuals.
- 26 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 12 (15) , 31575-31587
Open AccessUrine-Powered Batteryless Sensor Node With Printed Harvesters and Sensors for Smart Diapers
As the global population ages, caregivers encounter significant challenges in monitoring wet diapers and assessing the volumes of voided fluids in adult incontinence products. Recent advancements in smart-diaper technology address these issues, but challenges persist with integrating electronics, frequent removal and reapplication, and managing batteries. This study presents a batteryless urine-powered IoT sensor node using printed energy harvesters (EH) and capacitive sensors integrated with an ultralow-power integrated circuit for disposable smart diapers. Coplanar capacitive sensors and electrochemical EH are printed on the flexible substrate using environment-friendly materials. An ultralow power frontend interface is developed, which is powered by the harvested energy from urine. Laboratory measurements validate the functionality of on-chip electronics and the performance of in-diaper sensors and EH. The system demonstrates effective energy harvesting by maintaining a stable regulated voltage of 1.1 V with urine volumes of 90 ml or more, powering the front-end electronics continuously for 6 h. The proposed system successfully demonstrated the detection of multiple urination events in the diaper and quantified the voided volume as low as 30 ml. The results demonstrated in this work pave the way for cost-effective, disposable, and environmentally friendly solutions for smart diapers, enhancing both efficiency and comfort for caregivers and elderly individuals.
- Open Access
- 15 April 2025
- Published by Springer Nature in SN Computer Science
- Vol. 6 (4) , 1-10
Printed Energy Harvesting Electrodes: Sustainable Power Solutions for Batteryless Smart Diapers
Amid the rapid expansion of internet-of-things (IoT) devices, one of the most significant challenges is how to power these wireless sensor nodes adopting sustainable and environment-friendly solutions as the conventional batteries are inadequate to meet the power demands of the vast IoT ecosystem. Recent years have witnessed remarkable advancements in IoT sensor electronics, particularly in wearable biomedical devices. Innovative approaches have emerged to design energy-optimized electronic systems, opening the door to batteryless applications through energy harvesting techniques. In this study, a novel energy harvesting solution is proposed by designing sustainable energy harvesting electrodes, leveraging the capabilities of printed electronics technology. These electrodes are engineered directly on diaper back sheets to harvest green energy from urine with the ultimate goal of powering energy-efficient wearable IoT sensor nodes for batteryless smart diapers. The study encompasses a comprehensive characterization of these sustainable harvesting electrodes, involving experiments conducted within a controlled laboratory environment employing both in-jar and in-diaper deployment. The results demonstrate the great promise of continuously powering the IoT sensor nodes overnight to have batteryless smart diaper operations. This research highlights a significant stride towards addressing the power challenges of the ever-expanding IoT ecosystem.
- 15 April 2025
- Published by Springer Nature in SN Computer Science
- Vol. 6 (4) , 1-10
Open AccessPrinted Energy Harvesting Electrodes: Sustainable Power Solutions for Batteryless Smart Diapers
Amid the rapid expansion of internet-of-things (IoT) devices, one of the most significant challenges is how to power these wireless sensor nodes adopting sustainable and environment-friendly solutions as the conventional batteries are inadequate to meet the power demands of the vast IoT ecosystem. Recent years have witnessed remarkable advancements in IoT sensor electronics, particularly in wearable biomedical devices. Innovative approaches have emerged to design energy-optimized electronic systems, opening the door to batteryless applications through energy harvesting techniques. In this study, a novel energy harvesting solution is proposed by designing sustainable energy harvesting electrodes, leveraging the capabilities of printed electronics technology. These electrodes are engineered directly on diaper back sheets to harvest green energy from urine with the ultimate goal of powering energy-efficient wearable IoT sensor nodes for batteryless smart diapers. The study encompasses a comprehensive characterization of these sustainable harvesting electrodes, involving experiments conducted within a controlled laboratory environment employing both in-jar and in-diaper deployment. The results demonstrate the great promise of continuously powering the IoT sensor nodes overnight to have batteryless smart diaper operations. This research highlights a significant stride towards addressing the power challenges of the ever-expanding IoT ecosystem.
- Open Access
- 28 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (9) , 14443-14453
Smart Diaper With Printed Capacitive Sensors and Integrated Front-End to Monitor Voided Fluid Volume
As the demographic structure of the global population continues to shift towards an aging population, caregivers encounter formidable obstacles in detecting wetness events and assessing the quantity of voided volume within diapers. Nevertheless, the integration of electronics with diapers, frequent removal and reapplication, and battery management still pose practical challenges. In this study, a solution of carbon and silver printed flexible capacitive sensors interfaced with a custom-designed application-specific integrated circuit (ASIC) is proposed to detect urination events and estimate voided volumes in diapers. A power-optimized application-specific front-end interface circuit is developed to enhance power efficiency and reduce battery maintenance. The circuit is designed to support power-harvesting-based operations and to reduce reliance on external sources, consuming a maximum power of 3.05 μW. In vitro measurements validate on-chip electronics functionality and sensor performance to detect and quantify voided fluid volume as low as 50 ml. The promising results pave the way for cost-effective, disposable solutions in smart diapers. The proposed solution improves efficiency and comfort for both caregivers and elderly individuals.
- 28 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (9) , 14443-14453
Open AccessSmart Diaper With Printed Capacitive Sensors and Integrated Front-End to Monitor Voided Fluid Volume
As the demographic structure of the global population continues to shift towards an aging population, caregivers encounter formidable obstacles in detecting wetness events and assessing the quantity of voided volume within diapers. Nevertheless, the integration of electronics with diapers, frequent removal and reapplication, and battery management still pose practical challenges. In this study, a solution of carbon and silver printed flexible capacitive sensors interfaced with a custom-designed application-specific integrated circuit (ASIC) is proposed to detect urination events and estimate voided volumes in diapers. A power-optimized application-specific front-end interface circuit is developed to enhance power efficiency and reduce battery maintenance. The circuit is designed to support power-harvesting-based operations and to reduce reliance on external sources, consuming a maximum power of 3.05 μW. In vitro measurements validate on-chip electronics functionality and sensor performance to detect and quantify voided fluid volume as low as 50 ml. The promising results pave the way for cost-effective, disposable solutions in smart diapers. The proposed solution improves efficiency and comfort for both caregivers and elderly individuals.
- 4 January 2024
- Published by Springer Nature
- p. 414-422
Evaluation of Printed Coplanar Capacitive Sensors for Reliable Quantification of Fluids in Adult Diaper
- 4 January 2024
- Published by Springer Nature
- p. 414-422
Evaluation of Printed Coplanar Capacitive Sensors for Reliable Quantification of Fluids in Adult Diaper
- 25 September 2023
- Published by Springer Nature
- p. 237-245
Development of Capacitive Sensors to Detect and Quantify Fluids in the Adult Diaper
- 25 September 2023
- Published by Springer Nature
- p. 237-245
Development of Capacitive Sensors to Detect and Quantify Fluids in the Adult Diaper