Cidan Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Cidan Huang has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Baosheng Zhu
Department of Medical Genetics, Yunnan Provincial Key Laboratory of Birth Defects and Genetic Diseases, NHC Key Laboratory of Healthy Birth and Birth Defect Prevention in Western China, The First People’s Hospital of Yunnan Province & The Affiliated Hospital of Kunming University of Science and Technology, Kunming, China
2 shared publications - Hui Zou
Neonatal Disease Screening Center, Jinan Maternity and Child Health Hospital Affiliated to Shandong First Medical University, Jinan 250001, China
2 shared publications - Jizhen Feng
Department of Genetic, Shijiazhuang Maternal and Child Health Hospital, Shijiazhuang 050006, China
2 shared publications - Lianshu Han
Department of Pediatric Endocrinology and Genetic Metabolism, Xinhua Hospital, Shanghai Institute of Pediatric Research, Shanghai Jiao Tong University School of Medicine, Shanghai, China
2 shared publications - Xiaohua Wang
Inner Mongolia Maternity and Child Health Care Hospital, Hohhot, China
2 shared publications - Yinhong Zhang
Department of Medical Genetics, NHC Key Laboratory of Healthy Birth and Birth Defect Prevention in Western China, The Affiliated Hospital of Kunming University of Science and Technology, The First People's Hospital of Yunnan Province, Kunming, 650032, China
2 shared publications
Latest Publications
- Open Access
- 29 November 2024
- Published by MDPI AG in International Journal of Neonatal Screening
- Vol. 10 (4) , 78
Newborn Genetic Screening Improves the Screening Efficiency for Congenital Hypothyroidism: A Prospective Multicenter Study in China
Newborn congenital hypothyroidism (CH) screening has been widely used worldwide. The objective of this study was to evaluate the effectiveness of applying biochemical and gene panel sequencing as screening tests for CH and to analyze the mutation spectrum of CH in China. Newborns were prospectively recruited from eight hospitals in China between February and December 2021. Clinical characteristics were collected. Second-generation sequencing was used to detect four CH-related genes, and the genetic patterns of the pathogenic genes were analyzed. We analyzed the relationship between genotype and biochemical phenotype. A total of 29,601 newborns were screened for CH. Gene panel sequencing identified 18 patients, including 10 patients affected by biochemically and genetically screened disorders and 8 patients affected by solely genetically screened disorders. The predictive positive value of genetic screening was 34.62%, which was much greater than that of biochemical screening alone (17.99%). A total of 94 cases of congenital thyroid dysfunction were confirmed by biochemical and genetic screening, including 30 CHs and 64 isolated hyperthyrotropinemia (HTT), with an incidence of 1/987 for CH and 1/463 for HTT, and a total incidence of 1/315 for hypothyroidism. The incidence rate and number of patients in Jinan were the highest, and the incidence rates in Shijiazhuang and Shanghai were the lowest. The gene mutation rate in this study was 19.1%, mainly DUOX2 mutation. The most common variant of DUOX2 was c.1588A>T(p.Lys530*). There was only a difference in sFT4 between groups with gene mutations and those without mutations. Genetic screening is a supplement to biochemical screening. Combining biochemical screening with genetic screening is useful for improving screening efficiency. The incidence of CH in China according to a multicenter study of nearly 30,000 NBS surveys was 1/315. DUOX2 gene mutations are commonly detected in these patients.
- 29 November 2024
- Published by MDPI AG in International Journal of Neonatal Screening
- Vol. 10 (4) , 78
Open AccessNewborn Genetic Screening Improves the Screening Efficiency for Congenital Hypothyroidism: A Prospective Multicenter Study in China
Newborn congenital hypothyroidism (CH) screening has been widely used worldwide. The objective of this study was to evaluate the effectiveness of applying biochemical and gene panel sequencing as screening tests for CH and to analyze the mutation spectrum of CH in China. Newborns were prospectively recruited from eight hospitals in China between February and December 2021. Clinical characteristics were collected. Second-generation sequencing was used to detect four CH-related genes, and the genetic patterns of the pathogenic genes were analyzed. We analyzed the relationship between genotype and biochemical phenotype. A total of 29,601 newborns were screened for CH. Gene panel sequencing identified 18 patients, including 10 patients affected by biochemically and genetically screened disorders and 8 patients affected by solely genetically screened disorders. The predictive positive value of genetic screening was 34.62%, which was much greater than that of biochemical screening alone (17.99%). A total of 94 cases of congenital thyroid dysfunction were confirmed by biochemical and genetic screening, including 30 CHs and 64 isolated hyperthyrotropinemia (HTT), with an incidence of 1/987 for CH and 1/463 for HTT, and a total incidence of 1/315 for hypothyroidism. The incidence rate and number of patients in Jinan were the highest, and the incidence rates in Shijiazhuang and Shanghai were the lowest. The gene mutation rate in this study was 19.1%, mainly DUOX2 mutation. The most common variant of DUOX2 was c.1588A>T(p.Lys530*). There was only a difference in sFT4 between groups with gene mutations and those without mutations. Genetic screening is a supplement to biochemical screening. Combining biochemical screening with genetic screening is useful for improving screening efficiency. The incidence of CH in China according to a multicenter study of nearly 30,000 NBS surveys was 1/315. DUOX2 gene mutations are commonly detected in these patients.
- Open Access
- 29 March 2024
- Published by MDPI AG in International Journal of Neonatal Screening
- Vol. 10 (2) , 28
Newborn Screening for Inborn Errors of Metabolism by Next-Generation Sequencing Combined with Tandem Mass Spectrometry
The aim of this study was to observe the outcomes of newborn screening (NBS) in a certain population by using next-generation sequencing (NGS) as a first-tier screening test combined with tandem mass spectrometry (MS/MS). We performed a multicenter study of 29,601 newborns from eight screening centers with NBS via NGS combined with MS/MS. A custom-designed panel targeting the coding region of the 142 genes of 128 inborn errors of metabolism (IEMs) was applied as a first-tier screening test, and expanded NBS using MS/MS was executed simultaneously. In total, 52 genes associated with the 38 IEMs screened by MS/MS were analyzed. The NBS performance of these two methods was analyzed and compared respectively. A total of 23 IEMs were diagnosed via NGS combined with MS/MS. The incidence of IEMs was approximately 1 in 1287. Within separate statistical analyses, the positive predictive value (PPV) for MS/MS was 5.29%, and the sensitivity was 91.3%. However, for genetic screening alone, the PPV for NGS was 70.83%, with 73.91% sensitivity. The three most common IEMs were methylmalonic academia (MMA), primary carnitine deficiency (PCD) and phenylketonuria (PKU). The five genes with the most common carrier frequencies were PAH (1:42), PRODH (1:51), MMACHC (1:52), SLC25A13 (1:55) and SLC22A5 (1:63). Our study showed that NBS combined with NGS and MS/MS improves the performance of screening methods, optimizes the process, and provides accurate diagnoses.
- 29 March 2024
- Published by MDPI AG in International Journal of Neonatal Screening
- Vol. 10 (2) , 28
Open AccessNewborn Screening for Inborn Errors of Metabolism by Next-Generation Sequencing Combined with Tandem Mass Spectrometry
The aim of this study was to observe the outcomes of newborn screening (NBS) in a certain population by using next-generation sequencing (NGS) as a first-tier screening test combined with tandem mass spectrometry (MS/MS). We performed a multicenter study of 29,601 newborns from eight screening centers with NBS via NGS combined with MS/MS. A custom-designed panel targeting the coding region of the 142 genes of 128 inborn errors of metabolism (IEMs) was applied as a first-tier screening test, and expanded NBS using MS/MS was executed simultaneously. In total, 52 genes associated with the 38 IEMs screened by MS/MS were analyzed. The NBS performance of these two methods was analyzed and compared respectively. A total of 23 IEMs were diagnosed via NGS combined with MS/MS. The incidence of IEMs was approximately 1 in 1287. Within separate statistical analyses, the positive predictive value (PPV) for MS/MS was 5.29%, and the sensitivity was 91.3%. However, for genetic screening alone, the PPV for NGS was 70.83%, with 73.91% sensitivity. The three most common IEMs were methylmalonic academia (MMA), primary carnitine deficiency (PCD) and phenylketonuria (PKU). The five genes with the most common carrier frequencies were PAH (1:42), PRODH (1:51), MMACHC (1:52), SLC25A13 (1:55) and SLC22A5 (1:63). Our study showed that NBS combined with NGS and MS/MS improves the performance of screening methods, optimizes the process, and provides accurate diagnoses.