Alexandros Moniakis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alexandros Moniakis has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Amna Hussein
Department of Neurosurgery, Houston Methodist, Houston, USA
4 shared publications - Annie Pico
University of Arizona, Phoenix, Arizona
4 shared publications - Esteban Quiceno
Department of Neurosurgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, USA
4 shared publications - Isabel L. Bauer
University of Arizona, Phoenix, Arizona
4 shared publications - Michael Prim
University of Arizona, Phoenix, Arizona
4 shared publications - Ali A. Baaj
University of Arizona, Phoenix, Arizona
3 shared publications
Latest Publications
- Open Access
- 13 November 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (22) , 8881
Cottonoid-Guided Dynamic Ultrasound Navigation During Brain Surgery: A Technical Note and Case Series
Intraoperative ultrasound (ioUS) provides real-time imaging during cranial surgery and may be particularly useful when the reliability of conventional neuronavigation is reduced by brain shift, tissue distortion, or registration challenges. Cottonoid patties have previously been described as echogenic markers for intraoperative orientation, but their use has remained limited. In this technical note and case series, we describe a simple technique combining cottonoids with ioUS to provide a dynamic intraoperative reference during tumor resection. By exploiting the intrinsic hyperechogenicity of cottonoids and their readily identifiable movement during gentle manipulation, the technique was used to confirm surgical trajectories, support depth perception, and assist with spatial orientation throughout the procedure. We report a consecutive series of 12 patients with intracranial tumors in different anatomical locations and surgical positions, with particular emphasis on posterior fossa and occipital lesions. Rather than introducing a novel concept, the present Technical Note extends previous proof-of-concept experience by describing the practical transferability of cottonoid-guided ioUS to an independent consecutive adult cohort and by detailing its repeated use throughout the operative workflow, from initial trajectory confirmation to resection-cavity assessment. Trajectory confirmation was estimated by the operating surgeon to require less than 30 s in all cases, and no complications attributable to the technique were observed. Gross-total resection, assessed by postoperative magnetic resonance imaging, was achieved in all patients. The series also provides practical experience with posterior fossa and prone-position procedures, settings that remain comparatively underrepresented in the published literature. Our experience suggests that cottonoid-guided ioUS is a feasible, inexpensive, and practical adjunct to conventional neuronavigation, providing a dynamic reference that reflects current intraoperative anatomy.
- 13 November 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (22) , 8881
Open AccessCottonoid-Guided Dynamic Ultrasound Navigation During Brain Surgery: A Technical Note and Case Series
Intraoperative ultrasound (ioUS) provides real-time imaging during cranial surgery and may be particularly useful when the reliability of conventional neuronavigation is reduced by brain shift, tissue distortion, or registration challenges. Cottonoid patties have previously been described as echogenic markers for intraoperative orientation, but their use has remained limited. In this technical note and case series, we describe a simple technique combining cottonoids with ioUS to provide a dynamic intraoperative reference during tumor resection. By exploiting the intrinsic hyperechogenicity of cottonoids and their readily identifiable movement during gentle manipulation, the technique was used to confirm surgical trajectories, support depth perception, and assist with spatial orientation throughout the procedure. We report a consecutive series of 12 patients with intracranial tumors in different anatomical locations and surgical positions, with particular emphasis on posterior fossa and occipital lesions. Rather than introducing a novel concept, the present Technical Note extends previous proof-of-concept experience by describing the practical transferability of cottonoid-guided ioUS to an independent consecutive adult cohort and by detailing its repeated use throughout the operative workflow, from initial trajectory confirmation to resection-cavity assessment. Trajectory confirmation was estimated by the operating surgeon to require less than 30 s in all cases, and no complications attributable to the technique were observed. Gross-total resection, assessed by postoperative magnetic resonance imaging, was achieved in all patients. The series also provides practical experience with posterior fossa and prone-position procedures, settings that remain comparatively underrepresented in the published literature. Our experience suggests that cottonoid-guided ioUS is a feasible, inexpensive, and practical adjunct to conventional neuronavigation, providing a dynamic reference that reflects current intraoperative anatomy.
- Open Access
- 1 June 2026
- Published by MDPI AG in Healthcare
- Vol. 14 (11) , 1534
Multidisciplinary Management of Emergency Neurosurgery for Intracerebral Hemorrhage During Pregnancy: A Case Report
Background: Acute neurosurgical emergencies during pregnancy are rare but pose significant challenges due to the need for simultaneous management of two interdependent patients. Evidence remains limited, and standardized multidisciplinary protocols are lacking. Case Presentation: A 38-year-old woman at 32 + 4 weeks of gestation presented with acute left hemiparesis secondary to right capsulo-insular intracerebral hemorrhage with mass effect. Following initial conservative management, neurological deterioration and hematoma expansion necessitated emergency craniotomy. A structured multidisciplinary approach was implemented involving neurosurgery, anesthesiology, obstetrics, and neonatology, with predefined roles, continuous intraoperative fetal monitoring, and readiness for emergency cesarean delivery. Anesthetic management balanced maternal neuroprotection with preservation of uteroplacental perfusion. Surgery was completed without fetal compromise. The patient demonstrated neurological improvement and was transferred on postoperative day 13. Elective cesarean delivery was performed at 36 weeks. Conclusions: This case illustrates that emergency neurosurgery during pregnancy may be feasible in selected settings when supported by structured multidisciplinary coordination. Key practical elements included continuous fetal monitoring, predefined team roles, and immediate availability of obstetric and neonatal support. In this individual case, these components facilitated intraoperative decision-making and were associated with favorable maternal and fetal outcomes; however, their individual contribution cannot be determined from a single clinical experience. Further evidence is needed to assess the applicability of this approach across different clinical scenarios.
- 1 June 2026
- Published by MDPI AG in Healthcare
- Vol. 14 (11) , 1534
Open AccessMultidisciplinary Management of Emergency Neurosurgery for Intracerebral Hemorrhage During Pregnancy: A Case Report
Background: Acute neurosurgical emergencies during pregnancy are rare but pose significant challenges due to the need for simultaneous management of two interdependent patients. Evidence remains limited, and standardized multidisciplinary protocols are lacking. Case Presentation: A 38-year-old woman at 32 + 4 weeks of gestation presented with acute left hemiparesis secondary to right capsulo-insular intracerebral hemorrhage with mass effect. Following initial conservative management, neurological deterioration and hematoma expansion necessitated emergency craniotomy. A structured multidisciplinary approach was implemented involving neurosurgery, anesthesiology, obstetrics, and neonatology, with predefined roles, continuous intraoperative fetal monitoring, and readiness for emergency cesarean delivery. Anesthetic management balanced maternal neuroprotection with preservation of uteroplacental perfusion. Surgery was completed without fetal compromise. The patient demonstrated neurological improvement and was transferred on postoperative day 13. Elective cesarean delivery was performed at 36 weeks. Conclusions: This case illustrates that emergency neurosurgery during pregnancy may be feasible in selected settings when supported by structured multidisciplinary coordination. Key practical elements included continuous fetal monitoring, predefined team roles, and immediate availability of obstetric and neonatal support. In this individual case, these components facilitated intraoperative decision-making and were associated with favorable maternal and fetal outcomes; however, their individual contribution cannot be determined from a single clinical experience. Further evidence is needed to assess the applicability of this approach across different clinical scenarios.
- Open Access
- 14 November 2025
- Published by Knowledge E DMCC in Journal of Spine Practice (JSP)
- Vol. 5 (1) , 28-45
Clinical Insight into Spinal Drop Metastasis: A Systematic Review
IntroductionPrimary intracranial tumors (PITs) rarely metastasize to the spine, and as such, the condition is poorly understood. This study aimed to provide an overview of the clinical manifestations, therapeutic trends, and prognosis of spinal drop metastases (SDM) resulting from PIT. ObjectiveTo enhance comprehension of SDM pathology, direct patient care, and encourage research participation. MethodsPubMed, Medline, Scopus, Embase, CINAHL, and Cochrane databases were searched for abstracts of individuals with PIT and SDM, according to the PRISMA guidelines. Kaplan– Meier and log-rank analyses of survival curves were performed for specific subgroups. ResultsOf 803 abstracts, 56 articles were selected, yielding 63 subjects. The mean age was 42.95 years, and 60.31% of the participants were male. The most prevalent symptoms were cervicalgia/lumbago (74.13%) and radiculopathy (63.79%). The estimated median survival following diagnosis of PIT was 10 months, and the mean survival was 32.68 months. The predicted median survival after SDM was 3 months, and the mean survival was 3.8 months. ConclusionThis study defines PIT-induced spinal metastases and calls for further research in this area. These data also provide patients and physicians with literature-based survival predictions.
- 14 November 2025
- Published by Knowledge E DMCC in Journal of Spine Practice (JSP)
- Vol. 5 (1) , 28-45
Open AccessClinical Insight into Spinal Drop Metastasis: A Systematic Review
IntroductionPrimary intracranial tumors (PITs) rarely metastasize to the spine, and as such, the condition is poorly understood. This study aimed to provide an overview of the clinical manifestations, therapeutic trends, and prognosis of spinal drop metastases (SDM) resulting from PIT. ObjectiveTo enhance comprehension of SDM pathology, direct patient care, and encourage research participation. MethodsPubMed, Medline, Scopus, Embase, CINAHL, and Cochrane databases were searched for abstracts of individuals with PIT and SDM, according to the PRISMA guidelines. Kaplan– Meier and log-rank analyses of survival curves were performed for specific subgroups. ResultsOf 803 abstracts, 56 articles were selected, yielding 63 subjects. The mean age was 42.95 years, and 60.31% of the participants were male. The most prevalent symptoms were cervicalgia/lumbago (74.13%) and radiculopathy (63.79%). The estimated median survival following diagnosis of PIT was 10 months, and the mean survival was 32.68 months. The predicted median survival after SDM was 3 months, and the mean survival was 3.8 months. ConclusionThis study defines PIT-induced spinal metastases and calls for further research in this area. These data also provide patients and physicians with literature-based survival predictions.
- Open Access
- 3 July 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (13) , 4719
Public Perception of Robot-Assisted Spine Surgery
Background/Objectives: The potential advantages of robotic assistance in spinal procedures are a growing area of interest, and patient perception plays a key role in its broader acceptance. However, public perception of robotic surgery in spinal operations remains unexplored. This study aims to assess the general public’s perceptions, expectations, and concerns regarding robot-assisted spine surgery. Methods: In the fall of 2024, a questionnaire was distributed to attendees at a public open day at the Neurocenter of Southern Switzerland, where the Globus ExcelsiusGPS™ spine surgery robot was demonstrated live on a mannequin. The 15-item questionnaire assessed demographic data, prior knowledge of medical robots, mental representations of surgical robots, expectations, and emotions after witnessing the demonstration. Data were analyzed using descriptive statistics, chi-square, Wilcoxon, McNemar tests, and logistic regression analysis. Results: A total of 109 questionnaires were collected. Most participants were female (64.4%) and had no direct experience with spinal pathology (79.8%). While 87.2% were aware of robotic surgery in general, only 65.1% specifically knew about its use in spine surgery. After witnessing the live demonstration, 81.9% felt reassured by the robot′s presence in surgery, compared to 61.3% before the demonstration (p = 0.007). Preference for robot-assisted surgery increased from 50.5% to 64.5% (p < 0.001). Notably, individuals with back-related issues showed greater confidence in the robot’s capabilities (p = 0.032). Conclusions: The general public perceives robotic spine surgery positively, viewing it as faster, more precise, and capable of performing tasks not readily performed by humans. The study highlights the importance of live demonstrations in enhancing trust and acceptance of robotic systems. Its findings have economic implications, as patients may be more likely to choose hospitals offering robot-assisted spine surgery. However, it is essential to also acknowledge alternative methods, such as computer-assisted navigation, which has demonstrated efficacy in spine surgery.
- 3 July 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (13) , 4719
Open AccessPublic Perception of Robot-Assisted Spine Surgery
Background/Objectives: The potential advantages of robotic assistance in spinal procedures are a growing area of interest, and patient perception plays a key role in its broader acceptance. However, public perception of robotic surgery in spinal operations remains unexplored. This study aims to assess the general public’s perceptions, expectations, and concerns regarding robot-assisted spine surgery. Methods: In the fall of 2024, a questionnaire was distributed to attendees at a public open day at the Neurocenter of Southern Switzerland, where the Globus ExcelsiusGPS™ spine surgery robot was demonstrated live on a mannequin. The 15-item questionnaire assessed demographic data, prior knowledge of medical robots, mental representations of surgical robots, expectations, and emotions after witnessing the demonstration. Data were analyzed using descriptive statistics, chi-square, Wilcoxon, McNemar tests, and logistic regression analysis. Results: A total of 109 questionnaires were collected. Most participants were female (64.4%) and had no direct experience with spinal pathology (79.8%). While 87.2% were aware of robotic surgery in general, only 65.1% specifically knew about its use in spine surgery. After witnessing the live demonstration, 81.9% felt reassured by the robot′s presence in surgery, compared to 61.3% before the demonstration (p = 0.007). Preference for robot-assisted surgery increased from 50.5% to 64.5% (p < 0.001). Notably, individuals with back-related issues showed greater confidence in the robot’s capabilities (p = 0.032). Conclusions: The general public perceives robotic spine surgery positively, viewing it as faster, more precise, and capable of performing tasks not readily performed by humans. The study highlights the importance of live demonstrations in enhancing trust and acceptance of robotic systems. Its findings have economic implications, as patients may be more likely to choose hospitals offering robot-assisted spine surgery. However, it is essential to also acknowledge alternative methods, such as computer-assisted navigation, which has demonstrated efficacy in spine surgery.
- Open Access
- 22 July 2024
- Published by Knowledge E DMCC in Journal of Spine Practice (JSP)
- Vol. 3 (2) , 52-60
Does Routine Post-Operative Use of Drainage in Minimally Invasive Lumbar Spine Surgery Offer Better Results?
Objective: The advantages of minimally invasive spine surgery (MISS) in lumbar degenerative diseases have been well described (less tissue damage, shorter hospital stay, better results in pain assessment). One aspect that has not yet been studied enough is the usage of a post-operative drain in MISS. The aim of this study was to determine whether drainage in MISS is necessary or not and what advantages or disadvantages its use offers. Materials - Methods: We conducted a systematic review of the published literature, searching articles published on Pubmed and Embasse until December 1st 2022, regarding MISS in the lumbar region and post-operative drain usage. Our inclusion criteria were original articles written in English and articles using minimally invasive techniques (usage of tubular retractors along with an endoscope or microscope, paramedian incision, percutaneous screw placement). 42 articles were assessed, and after careful examination and duplication exclusion, 26 research papers were included. Usage, type and duration of postoperative drainage, length of hospital stay, ambulation time and complications were extracted, and relevant results were pooled. Results: The majority of the included articles (80.7 %) reported using a negative-pressure post-operative drain tube. Drains were removed either 48 hours after surgery or when the drainage volume was less than 50ml/24h. Hospital stays and time to ambulation were shorter in cases where drainage was not used. There was no difference in complications between cases where drainage was used and those that it was not. Conclusion: The rationale behind post-operative drainage in MISS is to protect from surgical site infections and hematoma creation. Based on our study there is no evidence to support this hypothesis. On the contrary, our results suggest that the drawbacks of using a drain (pain, discomfort, anxiety, inconvenience of mobilisation, prolongation of hospitalisation) outweigh the advantages, thus making the routine use of postoperative drainage in MISS unnecessary.
- 22 July 2024
- Published by Knowledge E DMCC in Journal of Spine Practice (JSP)
- Vol. 3 (2) , 52-60
Open AccessDoes Routine Post-Operative Use of Drainage in Minimally Invasive Lumbar Spine Surgery Offer Better Results?
Objective: The advantages of minimally invasive spine surgery (MISS) in lumbar degenerative diseases have been well described (less tissue damage, shorter hospital stay, better results in pain assessment). One aspect that has not yet been studied enough is the usage of a post-operative drain in MISS. The aim of this study was to determine whether drainage in MISS is necessary or not and what advantages or disadvantages its use offers. Materials - Methods: We conducted a systematic review of the published literature, searching articles published on Pubmed and Embasse until December 1st 2022, regarding MISS in the lumbar region and post-operative drain usage. Our inclusion criteria were original articles written in English and articles using minimally invasive techniques (usage of tubular retractors along with an endoscope or microscope, paramedian incision, percutaneous screw placement). 42 articles were assessed, and after careful examination and duplication exclusion, 26 research papers were included. Usage, type and duration of postoperative drainage, length of hospital stay, ambulation time and complications were extracted, and relevant results were pooled. Results: The majority of the included articles (80.7 %) reported using a negative-pressure post-operative drain tube. Drains were removed either 48 hours after surgery or when the drainage volume was less than 50ml/24h. Hospital stays and time to ambulation were shorter in cases where drainage was not used. There was no difference in complications between cases where drainage was used and those that it was not. Conclusion: The rationale behind post-operative drainage in MISS is to protect from surgical site infections and hematoma creation. Based on our study there is no evidence to support this hypothesis. On the contrary, our results suggest that the drawbacks of using a drain (pain, discomfort, anxiety, inconvenience of mobilisation, prolongation of hospitalisation) outweigh the advantages, thus making the routine use of postoperative drainage in MISS unnecessary.
- 5 March 2024
- Published by Elsevier in World Neurosurgery
- Vol. 185, e878-e885
Clinical Outcomes and Complication Profile of Spine Surgery in Septuagenarians and Octogenarians: Case Series
- 5 March 2024
- Published by Elsevier in World Neurosurgery
- Vol. 185, e878-e885
Clinical Outcomes and Complication Profile of Spine Surgery in Septuagenarians and Octogenarians: Case Series
- 1 March 2024
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 40 (3) , 265-273
C2 versus C3 or C4 as the upper instrumented vertebra for long-segment cervical fusions: a systematic review and meta-analysis
OBJECTIVE: Selecting C2 versus C3 or C4 (i.e., C3/C4) as the rostral anchoring level in long-segment cervical fusions is a common clinical conundrum. The data regarding proximal failure in long constructs of the cervical spine is scarce. The objective of this study was to systematically review the published literature and perform a meta-analysis of the incidence for proximal adjacent-segment disease (ASD) in the context of long cervical fusions and cervicothoracic fusions ending in C2 versus those ending in the subaxial spine (C3 or C4). METHODS: Using the PRISMA guidelines, the authors performed a search of the PubMed/MEDLINE, Embase/Ovid, and Cochrane Central databases to identify all full-text articles in the English-language literature with the following inclusion criteria: 1) studies including patients with the upper instrumented vertebra (UIV) at C2 versus C3/C4; 2) patients undergoing ≥ 3-level posterior cervical fusion; and 3) indication for surgery of degenerative disc disease, cervical spondylotic myelopathy, or cervical deformity. Studies that were not published in the English language, case reports, review articles, letters to the editor, and meeting abstracts were excluded. A meta-analysis was conducted using a fixed-effects model when I2 values were below 70%. Conversely, when I2 values were equal to or greater than 70%, a random-effects model was used. A funnel plot was used to assess the presence of publication bias. RESULTS: Seven studies consisting of 1215 patients were included in the meta-analysis. There were 403 (32.8%) patients in the C2 UIV group and 812 (67.2%) patients in the C3/C4 UIV group. When the 7 studies were analyzed, the overall rate of reoperation was comparable between the C2 (9.2%) and C3/C4 (9.4%) UIV groups (p = 0.93) but the rate of surgical ASD due to proximal pathology was 1.2% and 3%, respectively (OR 0.36, 95% CI 0.15–0.86; p = 0.02). When comparing between groups, no statistical difference was found regarding the rate of reoperation due to distal pathology or surgical infection. CONCLUSIONS: Long-segment cervical or cervicothoracic constructs that anchor into C2 may have similar complication rates but lower revision rates for proximal ASD than constructs that anchor into the subaxial spine.
- 1 March 2024
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 40 (3) , 265-273
C2 versus C3 or C4 as the upper instrumented vertebra for long-segment cervical fusions: a systematic review and meta-analysis
OBJECTIVE: Selecting C2 versus C3 or C4 (i.e., C3/C4) as the rostral anchoring level in long-segment cervical fusions is a common clinical conundrum. The data regarding proximal failure in long constructs of the cervical spine is scarce. The objective of this study was to systematically review the published literature and perform a meta-analysis of the incidence for proximal adjacent-segment disease (ASD) in the context of long cervical fusions and cervicothoracic fusions ending in C2 versus those ending in the subaxial spine (C3 or C4). METHODS: Using the PRISMA guidelines, the authors performed a search of the PubMed/MEDLINE, Embase/Ovid, and Cochrane Central databases to identify all full-text articles in the English-language literature with the following inclusion criteria: 1) studies including patients with the upper instrumented vertebra (UIV) at C2 versus C3/C4; 2) patients undergoing ≥ 3-level posterior cervical fusion; and 3) indication for surgery of degenerative disc disease, cervical spondylotic myelopathy, or cervical deformity. Studies that were not published in the English language, case reports, review articles, letters to the editor, and meeting abstracts were excluded. A meta-analysis was conducted using a fixed-effects model when I2 values were below 70%. Conversely, when I2 values were equal to or greater than 70%, a random-effects model was used. A funnel plot was used to assess the presence of publication bias. RESULTS: Seven studies consisting of 1215 patients were included in the meta-analysis. There were 403 (32.8%) patients in the C2 UIV group and 812 (67.2%) patients in the C3/C4 UIV group. When the 7 studies were analyzed, the overall rate of reoperation was comparable between the C2 (9.2%) and C3/C4 (9.4%) UIV groups (p = 0.93) but the rate of surgical ASD due to proximal pathology was 1.2% and 3%, respectively (OR 0.36, 95% CI 0.15–0.86; p = 0.02). When comparing between groups, no statistical difference was found regarding the rate of reoperation due to distal pathology or surgical infection. CONCLUSIONS: Long-segment cervical or cervicothoracic constructs that anchor into C2 may have similar complication rates but lower revision rates for proximal ASD than constructs that anchor into the subaxial spine.