Matheos Giakoumi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Matheos Giakoumi has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Charalampos Konstantinou
Department of Civil and Environmental Engineering, University of Cyprus, Nicosia, Cyprus
4 shared publications Panos Papanastasiou
3 shared publications- Konstantinos Kapnisis
Department of Mechanical Engineering and Materials Science and Engineering, Cyprus University of Technology, Limassol 3036, Cyprus
2 shared publications - Pavlos S. Stephanou
Department of Chemical Engineering, Cyprus University of Technology, Limassol 3036, Cyprus
2 shared publications Andreas Anayiotos
Department of Mechanical Engineering and Materials Science and Engineering, Cyprus University of Technology, Limassol 3036, Cyprus
1 shared publication- Andreas Anayiotos
Department of Mechanical Engineering and Materials Science and Engineering, Cyprus University of Technology, Limassol 3036, Cyprus
1 shared publication
Latest Publications
- 6 December 2025
- Published by Elsevier in Process Safety and Environmental Protection
- Vol. 206
A Points of Interest (POIs)-based method for determining accident risks in hydrogen hubs and valleys
- 6 December 2025
- Published by Elsevier in Process Safety and Environmental Protection
- Vol. 206
A Points of Interest (POIs)-based method for determining accident risks in hydrogen hubs and valleys
- 18 August 2025
- Published by Elsevier in Energy Conversion and Management
- Vol. 345
A mathematical framework for underground hydrogen storage in reservoirs with geo-methanation and enhanced gas recovery
- 18 August 2025
- Published by Elsevier in Energy Conversion and Management
- Vol. 345
A mathematical framework for underground hydrogen storage in reservoirs with geo-methanation and enhanced gas recovery
- Open Access
- 4 November 2024
- Published by MDPI AG in Mathematical and Computational Applications
- Vol. 29 (6) , 101
Analytical Solutions of PBTK Models for Evaluating the Impact of Surface Diffusion Characteristics on the Leaching Profile of Implant Byproducts
Toxicokinetic or pharmacokinetic models, physiologically based or not, offer a unique avenue to understand the transport of toxins or pharmaceuticals in living organisms. The availability of analytical solutions to such models offers the means to engage in a plethora of applications. In the present work, we provide the framework to solve analytically such models using the matrix exponential, and we then apply this method to derive an explicit solution to four-to-five-compartment physiologically based toxicokinetic (PBTK) models considering a single- and an infinite-exponential expression for the amount of mass released from an implantable device. We also offer the conditions that need to be met for analytical solutions to be obtained when the kinetic rates are time-dependent functions. Our analysis compares the computation time between analytical and numerical solutions and characterizes the dependency of the maximum substance mass value and the time it occurs in the various tissue compartments from the material surface diffusion characteristics. Our analytical solutions, which have several advantages over the solutions obtained using numerical solvers, can be incorporated into in silico tools and provide valuable information for human health risk assessment.
- 4 November 2024
- Published by MDPI AG in Mathematical and Computational Applications
- Vol. 29 (6) , 101
Open AccessAnalytical Solutions of PBTK Models for Evaluating the Impact of Surface Diffusion Characteristics on the Leaching Profile of Implant Byproducts
Toxicokinetic or pharmacokinetic models, physiologically based or not, offer a unique avenue to understand the transport of toxins or pharmaceuticals in living organisms. The availability of analytical solutions to such models offers the means to engage in a plethora of applications. In the present work, we provide the framework to solve analytically such models using the matrix exponential, and we then apply this method to derive an explicit solution to four-to-five-compartment physiologically based toxicokinetic (PBTK) models considering a single- and an infinite-exponential expression for the amount of mass released from an implantable device. We also offer the conditions that need to be met for analytical solutions to be obtained when the kinetic rates are time-dependent functions. Our analysis compares the computation time between analytical and numerical solutions and characterizes the dependency of the maximum substance mass value and the time it occurs in the various tissue compartments from the material surface diffusion characteristics. Our analytical solutions, which have several advantages over the solutions obtained using numerical solvers, can be incorporated into in silico tools and provide valuable information for human health risk assessment.
- Open Access
- 25 March 2024
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 10 (4) , 2534-2551
A Predictive Toxicokinetic Model for Nickel Leaching from Vascular Stents
In vitro testing methods offer valuable insights into the corrosion vulnerability of metal implants and enable prompt comparison between devices. However, they fall short in predicting the extent of leaching and the biodistribution of implant byproducts under in vivo conditions. Physiologically based toxicokinetic (PBTK) models are capable of quantitatively establishing such correlations and therefore provide a powerful tool in advancing nonclinical methods to test medical implants and assess patient exposure to implant debris. In this study, we present a multicompartment PBTK model and a simulation engine for toxicological risk assessment of vascular stents. The mathematical model consists of a detailed set of constitutive equations that describe the transfer of nickel ions from the device to peri-implant tissue and circulation and the nickel mass exchange between blood and the various tissues/organs and excreta. Model parameterization was performed using (1) in-house-produced data from immersion testing to compute the device-specific diffusion parameters and (2) full-scale animal in situ implantation studies to extract the mammalian-specific biokinetic functions that characterize the time-dependent biodistribution of the released ions. The PBTK model was put to the test using a simulation engine to estimate the concentration-time profiles, along with confidence intervals through probabilistic Monte Carlo, of nickel ions leaching from the implanted devices and determine if permissible exposure limits are exceeded. The model-derived output demonstrated prognostic conformity with reported experimental data, indicating that it may provide the basis for the broader use of modeling and simulation tools to guide the optimal design of implantable devices in compliance with exposure limits and other regulatory requirements.
- 25 March 2024
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 10 (4) , 2534-2551
Open AccessA Predictive Toxicokinetic Model for Nickel Leaching from Vascular Stents
In vitro testing methods offer valuable insights into the corrosion vulnerability of metal implants and enable prompt comparison between devices. However, they fall short in predicting the extent of leaching and the biodistribution of implant byproducts under in vivo conditions. Physiologically based toxicokinetic (PBTK) models are capable of quantitatively establishing such correlations and therefore provide a powerful tool in advancing nonclinical methods to test medical implants and assess patient exposure to implant debris. In this study, we present a multicompartment PBTK model and a simulation engine for toxicological risk assessment of vascular stents. The mathematical model consists of a detailed set of constitutive equations that describe the transfer of nickel ions from the device to peri-implant tissue and circulation and the nickel mass exchange between blood and the various tissues/organs and excreta. Model parameterization was performed using (1) in-house-produced data from immersion testing to compute the device-specific diffusion parameters and (2) full-scale animal in situ implantation studies to extract the mammalian-specific biokinetic functions that characterize the time-dependent biodistribution of the released ions. The PBTK model was put to the test using a simulation engine to estimate the concentration-time profiles, along with confidence intervals through probabilistic Monte Carlo, of nickel ions leaching from the implanted devices and determine if permissible exposure limits are exceeded. The model-derived output demonstrated prognostic conformity with reported experimental data, indicating that it may provide the basis for the broader use of modeling and simulation tools to guide the optimal design of implantable devices in compliance with exposure limits and other regulatory requirements.
- 21 December 2023
- Published by Elsevier in Geomechanics for Energy and the Environment
- Vol. 37, 100532
A screening tool for carbon dioxide injection in gas reservoirs based on the material balance approach
- 21 December 2023
- Published by Elsevier in Geomechanics for Energy and the Environment
- Vol. 37, 100532
A screening tool for carbon dioxide injection in gas reservoirs based on the material balance approach