CXChaopeng Xu

Chaopeng Xu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Chaopeng Xu has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Novel Photon-Counting Laser Point Cloud Denoising Method Based on Spatial Distribution Hierarchical Clustering for Inland Lake Water Level Monitoring

    by Xin Lv, Xiao Wang, Xiaomeng Yang, Junfeng Xie, Fan Mo, Chaopeng Xu, Fangxv Zhang

    Inland lakes and reservoirs are critical components of global freshwater resources. However, traditional water level monitoring stations are costly to establish and maintain, particularly in remote areas. As an alternative, satellite altimetry has become a key tool for lake water level monitoring. Nevertheless, conventional radar altimetry techniques face accuracy limitations when monitoring small water bodies. The Ice, Cloud, and Land Elevation Satellite-2 (ICESat-2), equipped with a single-photon counting lidar system, offers enhanced precision and a smaller ground footprint, making it more suitable for small-scale water body monitoring. However, the water level data obtained from the ICESat-2 ATL13 inland water surface height product are limited in quantity, while the lake water level accuracy derived from the ATL08 product is relatively low. To overcome these challenges, this study proposes a Spatial Distribution-Based Hierarchical Clustering for Photon-Counting Laser altimeter (SD-HCPLA) for enhanced water level extraction, validated through experiments conducted at the Danjiangkou Reservoir. The proposed method first employs Landsat 8/9 imagery and the Normalized Difference Water Index (NDWI) to generate a water mask, which is then used to filter ATL03 photon data within the water body boundaries. Subsequently, a Minimum Spanning Tree (MST) is constructed by traversing all photon points, where the vertical distance between adjacent photons replaces the traditional Euclidean distance as the edge length, thereby facilitating the clustering and denoising of the point cloud data. The SD-HCPLA algorithm successfully obtained 41 days of valid water level data for the Danjiangkou Reservoir, achieving a correlation coefficient of 0.99 and an average error of 0.14 m. Compared with ATL08 and ATL13, the SD-HCPLA method yields higher data availability and improved accuracy in water level estimation. Furthermore, the proposed algorithm was applied to extract water level data for five lakes and reservoirs in Hubei Province from 2018 to 2023. The temporal variations and inter-correlations of water levels were analyzed, providing valuable insights for regional ecological environment monitoring and water resource management.


  • Open Access

    Fine Calibration Method for Laser Altimeter Pointing and Ranging Based on Dense Control Points

    by Chaopeng Xu, Fan Mo, Xiao Wang, Xiaomeng Yang, Junfeng Xie, Zhen Wen

    Satellite laser altimetry technology, a novel space remote sensing technique, actively acquires high-precision elevation information about the Earth’s surface. However, the accuracy of laser altimetry can be compromised by alterations in the satellite-ground environment, thermal dynamics, and cosmic radiation. These factors may induce subtle variations in the installation and internal structure of the spaceborne laser altimeter on the satellite platform, diminishing measurement precision. In-orbit calibration is thus essential to enhancing the precision of laser altimetry. Through collaborative calculations between satellite and ground stations, we can derive correction parameters for laser pointing and ranging, substantially improving the accuracy of satellite laser altimetry. This paper introduces a sophisticated calibration method for laser altimeter pointing and ranging that utilizes dense control points. The approach interpolates discrete ground control point data into continuous simulated terrain using empirical Bayesian kriging, subsequently categorizing the data for either pointing or ranging calibration according to their respective functions. Following this, a series of calibration experiments are conducted, prioritizing “pointing” followed by “ranging” and continuing until the variation in the ranging calibration results falls below a predefined threshold. We employed experimental data from ground control points (GCPs) in Xinjiang and Inner Mongolia, China, to calibrate the GaoFen-7 (GF-7) satellite Beam 2 laser altimeter as per the outlined method. The calibration outcomes were then benchmarked against those gleaned from infrared laser detector calibration, revealing disparities of 1.12 s in the pointing angle and 2 cm in the ranging correction value. Post validation with ground control points, the measurement accuracy was refined to 0.15 m. The experiments confirm that the proposed calibration method offers accuracy comparable to that of infrared laser detector calibration and can facilitate the updating of 1:10,000 topographic maps utilizing stereo optical imagery. Furthermore, this method is more cost-effective and demands fewer personnel for ground control point collection, enhancing resource efficiency compared to traditional infrared laser detector calibration. The proposed approach surpasses terrain-matching limitations when calibrating laser ranging parameters and presents a viable solution for achieving frequent and high-precision in-orbit calibration of laser altimetry satellites.


  • Open Access

    A Separate Calibration Method of Laser Pointing and Ranging for the GF-7 Satellite Laser That Does Not Require Field Detectors

    by Ren Liu, Junfeng Xie, Chaopeng Xu, Junze Zeng, Fan Mo, Xiaomeng Yang

    Satellite laser altimeters have been widely used in the surveying, mapping, forestry, and polar regions and by other industries due to their excellent elevation measurement accuracy. Satellite laser on-orbit geometry calibration is a necessary means to ensure elevation accuracy. This study proposes an iterative geometry calibration method for satellite laser altimeter pointing and ranging separation that does not require the use of field detectors. The DSM data were first used to complete the laser pointing calibration, and then the laser footprint elevation was measured accurately to complete the laser ranging calibration. The iterative calibration experiment was repeated until the convergence condition (i.e., the laser point difference was less than 1 × 10-5 degrees and the laser ranging difference was less than 0.01 m) was met, with the calibrated laser pointing angle and ranging separation used as the input parameters. In this work, the GaoFen-7 (GF-7) satellite laser was used as the test object and the actual laser pointing and ranging values derived from ground detector calibrations. The results verified that the pointing accuracy of the GF-7 beam 1 was 2 arcsec and that the ranging accuracy was 2 cm after applying the calibration method presented in this paper. The pointing accuracy of the GF-7 beam 2 was 2.2 arcsec, and the ranging accuracy was approximately 1 cm. This analysis demonstrated that the GF-7 laser mission exceeded its pointing angle requirement of 3 arcsec after laser pointing and ranging separation iterative calibrations were applied. Finally, ground control points were used to verify the calibrated elevation accuracy of the GF-7 satellite laser, and its accuracy on flat terrain was 0.18 m. In summary, it was proven that the satellite laser geometry calibration method proposed in the article is effective.