Yuri Alexandrovich Parkhisenko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yuri Alexandrovich Parkhisenko has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Sergey Viktorovich Barannikov
Voronezh State Medical University named after N.N. Burdenko
6 shared publications - Alexey Konstantinovich Vorontsov
Smolensk State Medical University
5 shared publications - Alexander Alexandrovich Bezaltynnykh
Smolensk State Medical University
4 shared publications - Evgeniy Fedorovich Cherednikov
N.N. Burdenko Voronezh State Medical University
4 shared publications - Evgeniy F. Cherednikov
N.N. Burdenko Voronezh State Medical University
3 shared publications Пархисенко Юрий Александрович
Воронежский государственный медицинский университет им. Н.Н. Бурденко
3 shared publications
Latest Publications
- Open Access
- 30 December 2025
- Published by Belgorod State University in Актуальные проблемы медицины
- Vol. 48 (4)
Neural Network Classification of the Type of Ulcerative Gastroduodenal Bleeding According to Endoscopic Images
Ulcerative gastroduodenal bleeding remains a serious problem in modern medicine. To determine the type of ulcerative bleeding, the Forrest classification is used worldwide, defining the tactics of treating patients with bleeding gastroduodenal ulcers. The ability to correctly classify the type of bleeding depends primarily on the experience of an endoscopist. With the development of artificial intelligence technologies, there are high expectations in improving the diagnosis and treatment of surgical diseases. This article discusses the possibility of developing an algorithm for recognizing the type of ulcerative bleeding from endoscopic images using machine learning models and integrating it into an expert medical decision support system. In the course of this study, the first Russian neural network classification was developed, which makes it possible to determine the type of ulcerative gastroduodenal bleeding with 75,56 % accuracy. The developed algorithm for recognizing the type of ulcerative bleeding is integrated into a mobile application as a tool to help in making medical decisions, which in the future will improve the quality of diagnosis and medical care for patients with gastrointestinal bleeding of ulcerative etiology.
- 30 December 2025
- Published by Belgorod State University in Актуальные проблемы медицины
- Vol. 48 (4)
Open AccessNeural Network Classification of the Type of Ulcerative Gastroduodenal Bleeding According to Endoscopic Images
Ulcerative gastroduodenal bleeding remains a serious problem in modern medicine. To determine the type of ulcerative bleeding, the Forrest classification is used worldwide, defining the tactics of treating patients with bleeding gastroduodenal ulcers. The ability to correctly classify the type of bleeding depends primarily on the experience of an endoscopist. With the development of artificial intelligence technologies, there are high expectations in improving the diagnosis and treatment of surgical diseases. This article discusses the possibility of developing an algorithm for recognizing the type of ulcerative bleeding from endoscopic images using machine learning models and integrating it into an expert medical decision support system. In the course of this study, the first Russian neural network classification was developed, which makes it possible to determine the type of ulcerative gastroduodenal bleeding with 75,56 % accuracy. The developed algorithm for recognizing the type of ulcerative bleeding is integrated into a mobile application as a tool to help in making medical decisions, which in the future will improve the quality of diagnosis and medical care for patients with gastrointestinal bleeding of ulcerative etiology.
- 26 December 2025
- Published by VSMU N.N. Burdenko in Journal of Experimental and Clinical Surgery
- Vol. 18 (4) , 248-257
Experimental use of a bioengineered heterograft in ventral hernioplasty in an infected wound
Background. Currently, the number of relapses after performed prosthetic hernioplasty techniques of the anterior abdominal wall, including those due to severe wound infection and rejection of the mesh prosthesis, reaches 5-10%. In this regard, the use of bioengineered transplants deprived of immune properties due to decellularization is a promising direction. The use of extracellular matrix promotes better engraftment of the material in the area of the hernial gate and, thereby, reduces the likelihood of wound complications in the postoperative period. However, in clinical practice, biological analogues of polypropylene mesh have low availability and high cost. The aim of the study was to experimentally evaluate the local and general reaction of the body to the implantation of a bioengineered heterograft into a simulated defect of the anterior abdominal wall in an infected wound. Materials and methods. The study was conducted on 90 male Wistar rats. The study objects were divided into three groups, comparable in number of observations (n=30 each) – the main group (onlay+bioengineered heterotransplant), the comparison group (onlay+polypropylene mesh, Lintex Esfil) and the control group (autoplasty). All animals were first formed a hernial defect along the white line of the abdomen, after which a staphylococcal suspension was injected into the wound to simulate an infected wound, and then the hernial defect was plasticized. In each group, the general and local reactions of the body to a particular material were evaluated on days 1, 5, 10, 30, and 180 after surgery. Results. Based on an assessment of the local and general body response to various types of plastic surgery of a simulated hernial defect of the anterior abdominal wall of rats in an infected wound, it was found that a bioengineered heterograft promotes more effective wound healing (n=30-100%) compared with a polypropylene mesh (n=25 - 83.3%), which is confirmed by laboratory and objective data. with data. Conclusion. The data obtained in the experiment allow us to consider the potential using bioengineered material in clinical practice, especially under increased risk of wound infection.
- 26 December 2025
- Published by VSMU N.N. Burdenko in Journal of Experimental and Clinical Surgery
- Vol. 18 (4) , 248-257
Experimental use of a bioengineered heterograft in ventral hernioplasty in an infected wound
Background. Currently, the number of relapses after performed prosthetic hernioplasty techniques of the anterior abdominal wall, including those due to severe wound infection and rejection of the mesh prosthesis, reaches 5-10%. In this regard, the use of bioengineered transplants deprived of immune properties due to decellularization is a promising direction. The use of extracellular matrix promotes better engraftment of the material in the area of the hernial gate and, thereby, reduces the likelihood of wound complications in the postoperative period. However, in clinical practice, biological analogues of polypropylene mesh have low availability and high cost. The aim of the study was to experimentally evaluate the local and general reaction of the body to the implantation of a bioengineered heterograft into a simulated defect of the anterior abdominal wall in an infected wound. Materials and methods. The study was conducted on 90 male Wistar rats. The study objects were divided into three groups, comparable in number of observations (n=30 each) – the main group (onlay+bioengineered heterotransplant), the comparison group (onlay+polypropylene mesh, Lintex Esfil) and the control group (autoplasty). All animals were first formed a hernial defect along the white line of the abdomen, after which a staphylococcal suspension was injected into the wound to simulate an infected wound, and then the hernial defect was plasticized. In each group, the general and local reactions of the body to a particular material were evaluated on days 1, 5, 10, 30, and 180 after surgery. Results. Based on an assessment of the local and general body response to various types of plastic surgery of a simulated hernial defect of the anterior abdominal wall of rats in an infected wound, it was found that a bioengineered heterograft promotes more effective wound healing (n=30-100%) compared with a polypropylene mesh (n=25 - 83.3%), which is confirmed by laboratory and objective data. with data. Conclusion. The data obtained in the experiment allow us to consider the potential using bioengineered material in clinical practice, especially under increased risk of wound infection.
- Open Access
- 17 November 2025
- Published by Federal Medical Biological Agency in Extreme Medicine
- Vol. 27 (4) , 490-499
Application of modified packing in the combination treatment of extensive traumatic liver injuries
Introduction. Traumatic liver injuries are a significant challenge in modern emergency surgery. Developing new methods for surgical hemostasis of traumatic liver injuries is an extremely relevant task in urgent surgery. Objective. Development and testing of surgical hemostasis for traumatic liver injuries using a modified packing technique. Materials and methods . A new method of surgical hemostasis for traumatic liver injuries was developed using cadaveric material. The clinical trial included 27 patients with severe traumatic liver injuries (AAST Grade IV). Patients were divided into the main (n = 14) and control (n = 13) groups. Patients in the main group were treated using a new method of surgical hemostasis for traumatic liver injuries, involving tamponade of the liver wounds with Surgitamp hemostatic gauze impregnated with Molselect G-50 granular sorbent, followed by modified liver packing with strips of polypropylene mesh implant. In the control group, surgical hemostasis was performed by tamponading the liver wound with hemostatic sponges followed by suturing. The effectiveness of the proposed method was evaluated based on the following parameters: definitive hemostasis, number of recurrent hemorrhages, number of reсurrent operations, mortality, hospital stay duration, intensive care unit stay duration. Statistical analysis of the study results was performed using the Statistica 10 software. Results . The application of modified packing in the combination treatment of patients with severe traumatic liver injuries increased the reliability of definitive hemostasis from 46.2% to 92.8% (p = 0.0391), reduced the number of re-bleeding episodes and re-operations from 38.4% to 7.1% (p = 0.0391), and decreased the mortality rate from 38.4% to 14.2% (p > 0.05). Conclusions . The application of the new combined method of surgical hemostasis improved the treatment outcomes for patients with severe traumatic liver injuries by increasing the reliability of definitive hemostasis, reducing re-bleeding and re-operations, and lowering mortality.
- 17 November 2025
- Published by Federal Medical Biological Agency in Extreme Medicine
- Vol. 27 (4) , 490-499
Open AccessApplication of modified packing in the combination treatment of extensive traumatic liver injuries
Introduction. Traumatic liver injuries are a significant challenge in modern emergency surgery. Developing new methods for surgical hemostasis of traumatic liver injuries is an extremely relevant task in urgent surgery. Objective. Development and testing of surgical hemostasis for traumatic liver injuries using a modified packing technique. Materials and methods . A new method of surgical hemostasis for traumatic liver injuries was developed using cadaveric material. The clinical trial included 27 patients with severe traumatic liver injuries (AAST Grade IV). Patients were divided into the main (n = 14) and control (n = 13) groups. Patients in the main group were treated using a new method of surgical hemostasis for traumatic liver injuries, involving tamponade of the liver wounds with Surgitamp hemostatic gauze impregnated with Molselect G-50 granular sorbent, followed by modified liver packing with strips of polypropylene mesh implant. In the control group, surgical hemostasis was performed by tamponading the liver wound with hemostatic sponges followed by suturing. The effectiveness of the proposed method was evaluated based on the following parameters: definitive hemostasis, number of recurrent hemorrhages, number of reсurrent operations, mortality, hospital stay duration, intensive care unit stay duration. Statistical analysis of the study results was performed using the Statistica 10 software. Results . The application of modified packing in the combination treatment of patients with severe traumatic liver injuries increased the reliability of definitive hemostasis from 46.2% to 92.8% (p = 0.0391), reduced the number of re-bleeding episodes and re-operations from 38.4% to 7.1% (p = 0.0391), and decreased the mortality rate from 38.4% to 14.2% (p > 0.05). Conclusions . The application of the new combined method of surgical hemostasis improved the treatment outcomes for patients with severe traumatic liver injuries by increasing the reliability of definitive hemostasis, reducing re-bleeding and re-operations, and lowering mortality.
- 30 September 2025
- Published by Ryazan State Medical University in Nauka Molodykh (Eruditio Juvenium)
- Vol. 13 (3)
The Effect of Dressings with Granulated Sorbent and Modern Antiseptic Agents on the Treatment of Wound Defects in Patients with Diabetic Foot Syndrome
INTRODUCTION: Treatment of wounds in diabetic foot syndrome (DFS) is an important surgical problem. In addition to pain syndrome, infectious complications, risk of amputation and mobility disorders, diabetic foot ulcers are also associated with serious economic, social and psychological consequences. In the treatment of skin and soft tissue defects in patients with diabetes mellitus (DM), various methods of drug administration are proposed. However, there is still no single algorithm for choosing dressings and no single treatment algorithm to achieve maximum wound healing rate and reduce the incidence of patient disability. AIM: To evaluate the effect of dressings with granulated sorbent and modern antiseptic means on the treatment of wound defects in patients with DFS. MATERIALS AND METHODS: To determine the sample size an a priori analysis of power was conducted. Thirty three patients aged above 18 with type 2 DM and DFS were examined and treated in the ambulatory setting. The patients were randomly divided into 2 groups: group 1 was treated with the proposed method using chlorhexidine-dioxidine mixture (CDM) and granulated sorbent, group 2 received treatment with standard methods using antiseptic dressings with iodophor solutions (povidone-iodine, betadine, iodopyrone) and levomekol/levometil ointments. RESULTS: The duration of treatment averaged 17.27±3.96 weeks. The duration of the confirmed type 2 DM averaged 11.97±6.10 weeks. The dynamics of each wound healing was calculated based on the initial wound size and also the healing rate of each particular wound. In the main group the ratio of the healing rate to the initial wound area was 0.069±0.026. In the control group the parameter was lower: 0.055±0.006. A program was developed that permits calculating the predicted wound healing rate in less than 1 minute depending on the initial dimensions and type of dressing used. CONCLUSION: Elucidation of the importance of the influence of the used type of dressing on the duration of treatment and course of the wound process helps correct the management tactics for patients with DM to achieve better wound treatment results. The impact of dressing type can be assessed using a program developed for the study to estimate the predicted wound healing rate based on the initial wound size. This program enables the selection of the optimal dressing for each individual patient and wound.
- 30 September 2025
- Published by Ryazan State Medical University in Nauka Molodykh (Eruditio Juvenium)
- Vol. 13 (3)
The Effect of Dressings with Granulated Sorbent and Modern Antiseptic Agents on the Treatment of Wound Defects in Patients with Diabetic Foot Syndrome
INTRODUCTION: Treatment of wounds in diabetic foot syndrome (DFS) is an important surgical problem. In addition to pain syndrome, infectious complications, risk of amputation and mobility disorders, diabetic foot ulcers are also associated with serious economic, social and psychological consequences. In the treatment of skin and soft tissue defects in patients with diabetes mellitus (DM), various methods of drug administration are proposed. However, there is still no single algorithm for choosing dressings and no single treatment algorithm to achieve maximum wound healing rate and reduce the incidence of patient disability. AIM: To evaluate the effect of dressings with granulated sorbent and modern antiseptic means on the treatment of wound defects in patients with DFS. MATERIALS AND METHODS: To determine the sample size an a priori analysis of power was conducted. Thirty three patients aged above 18 with type 2 DM and DFS were examined and treated in the ambulatory setting. The patients were randomly divided into 2 groups: group 1 was treated with the proposed method using chlorhexidine-dioxidine mixture (CDM) and granulated sorbent, group 2 received treatment with standard methods using antiseptic dressings with iodophor solutions (povidone-iodine, betadine, iodopyrone) and levomekol/levometil ointments. RESULTS: The duration of treatment averaged 17.27±3.96 weeks. The duration of the confirmed type 2 DM averaged 11.97±6.10 weeks. The dynamics of each wound healing was calculated based on the initial wound size and also the healing rate of each particular wound. In the main group the ratio of the healing rate to the initial wound area was 0.069±0.026. In the control group the parameter was lower: 0.055±0.006. A program was developed that permits calculating the predicted wound healing rate in less than 1 minute depending on the initial dimensions and type of dressing used. CONCLUSION: Elucidation of the importance of the influence of the used type of dressing on the duration of treatment and course of the wound process helps correct the management tactics for patients with DM to achieve better wound treatment results. The impact of dressing type can be assessed using a program developed for the study to estimate the predicted wound healing rate based on the initial wound size. This program enables the selection of the optimal dressing for each individual patient and wound.
- Open Access
- 30 June 2025
- Published by Belgorod State University in Актуальные проблемы медицины
- Vol. 48 (2)
Program for Assessing the Severity of Patients with Traumatic Liver Injuries
The mortality rate for liver damage is currently at an extremely high level, reaching 58 %. This is due to massive intra-abdominal hemorrhage and the development of hepatic cell insufficiency in the early postoperative period. We aim to develop a mobile application to assess the severity of pathophysiological changes and determine the severity of patients with traumatic liver injuries. Materials and methods. The program is implemented for smartphones and tablets, which allows on-line and offline assessment of personalized clinical features of patients with traumatic liver injuries, with an integrated assessment of the severity of the patient in order to determine the tactics of intensive care. Results. When creating a mobile application, the Electron.js framework was used as a technological basis for JavaScript. Conclusion. This solution provided cross-platform support: web technologies were used for desktop versions (Windows, macOS, Linux), and adaptation to mobile OS (iOS, Android) was implemented through a single code base. The widespread use of the developed mobile application in clinical practice will increase the effectiveness of medical care for patients with traumatic liver injuries, reduce the number of complications, and improve the quality of specialist training in emergency medical care.
- 30 June 2025
- Published by Belgorod State University in Актуальные проблемы медицины
- Vol. 48 (2)
Open AccessProgram for Assessing the Severity of Patients with Traumatic Liver Injuries
The mortality rate for liver damage is currently at an extremely high level, reaching 58 %. This is due to massive intra-abdominal hemorrhage and the development of hepatic cell insufficiency in the early postoperative period. We aim to develop a mobile application to assess the severity of pathophysiological changes and determine the severity of patients with traumatic liver injuries. Materials and methods. The program is implemented for smartphones and tablets, which allows on-line and offline assessment of personalized clinical features of patients with traumatic liver injuries, with an integrated assessment of the severity of the patient in order to determine the tactics of intensive care. Results. When creating a mobile application, the Electron.js framework was used as a technological basis for JavaScript. Conclusion. This solution provided cross-platform support: web technologies were used for desktop versions (Windows, macOS, Linux), and adaptation to mobile OS (iOS, Android) was implemented through a single code base. The widespread use of the developed mobile application in clinical practice will increase the effectiveness of medical care for patients with traumatic liver injuries, reduce the number of complications, and improve the quality of specialist training in emergency medical care.
- 1 April 2024
- Published by Media Sphere Publishing Group in Russian Journal of Evidence-Based Gastroenterology
- Vol. 15 (1)
Experimental and morphological validation of Molselect G-50 sorbent for treating traumatic liver ruptures
Abdominal trauma, especially liver ruptures causing bleeding, poses a considerable challenge in surgical gastroenterology, often resulting in unfavorable clinical outcomes. In addition to using endovascular techniques and standard suturing for hemorrhage prevention, various formulations are employed for local hemostasis. However, their clinical efficacy falls short of medical specialists’ expectations. Recent findings on the granulated sorbent, Molsellect G-50, show promising preliminary outcomes as a potential local hemostatic agent. However, rigorous preclinical trials are needed to confirm its applicability. OBJECTIVE: To evaluate the hemostatic efficacy and tissue regeneration quality in the context of liver injuries utilizing the granulated sorbent, Molsellect G-50. MATERIALS AND METHODS The study involved 80 WISTAR rats replicating a standardized model of bleeding liver wounds. In the experimental group (n=40), hemostasis was achieved by introducing 0.5 g of Molsellect G-50, while the control group achieved hemostasis through suturing with absorbable synthetic thread 3/0 coated with a film based on polyglycolic acid. Evaluation included clinical parameters (bleeding duration, frequency of recurrent hemorrhages) and histopathological features of the liver’s response. RESULTS The application of Molsellect G-50 resulted in reduction in bleeding cessation time, decreasing from 385.9±3.87 sec to 243.4±7.66 sec (p=0.0001). The experimental group exhibited a 7.5% frequency of recurrent bleeding, while the control group manifested a significantly higher rate of 42.5% (p=0.0005). CONCLUSION This controlled study provides valuable insights into the potential utility of Molsellect G-50 as a local hemostatic agent for effective hemorrhage control.
- 1 April 2024
- Published by Media Sphere Publishing Group in Russian Journal of Evidence-Based Gastroenterology
- Vol. 15 (1)
Experimental and morphological validation of Molselect G-50 sorbent for treating traumatic liver ruptures
Abdominal trauma, especially liver ruptures causing bleeding, poses a considerable challenge in surgical gastroenterology, often resulting in unfavorable clinical outcomes. In addition to using endovascular techniques and standard suturing for hemorrhage prevention, various formulations are employed for local hemostasis. However, their clinical efficacy falls short of medical specialists’ expectations. Recent findings on the granulated sorbent, Molsellect G-50, show promising preliminary outcomes as a potential local hemostatic agent. However, rigorous preclinical trials are needed to confirm its applicability. OBJECTIVE: To evaluate the hemostatic efficacy and tissue regeneration quality in the context of liver injuries utilizing the granulated sorbent, Molsellect G-50. MATERIALS AND METHODS The study involved 80 WISTAR rats replicating a standardized model of bleeding liver wounds. In the experimental group (n=40), hemostasis was achieved by introducing 0.5 g of Molsellect G-50, while the control group achieved hemostasis through suturing with absorbable synthetic thread 3/0 coated with a film based on polyglycolic acid. Evaluation included clinical parameters (bleeding duration, frequency of recurrent hemorrhages) and histopathological features of the liver’s response. RESULTS The application of Molsellect G-50 resulted in reduction in bleeding cessation time, decreasing from 385.9±3.87 sec to 243.4±7.66 sec (p=0.0001). The experimental group exhibited a 7.5% frequency of recurrent bleeding, while the control group manifested a significantly higher rate of 42.5% (p=0.0005). CONCLUSION This controlled study provides valuable insights into the potential utility of Molsellect G-50 as a local hemostatic agent for effective hemorrhage control.
- Open Access
- 23 April 2023
- Published by Volgograd State Medical University in Journal of Volgograd State Medical University
- Vol. 20 (1) , 73-80
Morphological assessment of reparative regeneration of experimental bleeding liver wounds in the treatment of hemostatic agent Surgitamp and granular sorbent Molselect G-50
The problem of treating intra-abdominal bleeding in abdominal trauma is one of the most serious in urgent surgery. The most common cause of these hemorrhages is liver damage. For surgical hemostasis, local hemostatics and granular sorbents are becoming increasingly common. The aim of the study was to study in vivo the hemostatic properties and morphological features of the reparative regeneration of simulated bleeding liver wounds during treatment with the hemostatic agent Surgitamp and the sorbent Molselect G-50. The experiments were performed on 30 laboratory animals Chinchilla rabbits. After reproducing the model of a bleeding liver wound, bleeding was stopped in the experimental group (n = 15) by applying Molselect G-50 (4.0 g) powdered sorbent into the wound, followed by tamponing with Surgitamp hemostatic gauze (4.0 x 2.0 cm). Hemostasis in the control liver wound was carried out by applying a U-shaped suture with a PGA-3.0 thread until the edges of the wound converged. Morphological studies were performed on the 7th, 14th and 28th days of the experiment. Experimental studies have shown that the time to stop bleeding in the experimental group was 280.0 (264.0308.0) sec, in the control, the time of hemostasis was later 461.0 (420.0501.0) sec. Morphological studies have allowed us to establish differences in both the rate and quality of reparative regeneration of experimental simulated liver wounds compared with the control. Experimental studies using Molselect G-50 in combination with Surgistamp for local hemostasis of bleeding liver wounds in rabbits allowed us to conclude that such a combination makes it possible not only to reliably stop bleeding, but also promotes the stimulation of reparative regeneration.
- 23 April 2023
- Published by Volgograd State Medical University in Journal of Volgograd State Medical University
- Vol. 20 (1) , 73-80
Open AccessMorphological assessment of reparative regeneration of experimental bleeding liver wounds in the treatment of hemostatic agent Surgitamp and granular sorbent Molselect G-50
The problem of treating intra-abdominal bleeding in abdominal trauma is one of the most serious in urgent surgery. The most common cause of these hemorrhages is liver damage. For surgical hemostasis, local hemostatics and granular sorbents are becoming increasingly common. The aim of the study was to study in vivo the hemostatic properties and morphological features of the reparative regeneration of simulated bleeding liver wounds during treatment with the hemostatic agent Surgitamp and the sorbent Molselect G-50. The experiments were performed on 30 laboratory animals Chinchilla rabbits. After reproducing the model of a bleeding liver wound, bleeding was stopped in the experimental group (n = 15) by applying Molselect G-50 (4.0 g) powdered sorbent into the wound, followed by tamponing with Surgitamp hemostatic gauze (4.0 x 2.0 cm). Hemostasis in the control liver wound was carried out by applying a U-shaped suture with a PGA-3.0 thread until the edges of the wound converged. Morphological studies were performed on the 7th, 14th and 28th days of the experiment. Experimental studies have shown that the time to stop bleeding in the experimental group was 280.0 (264.0308.0) sec, in the control, the time of hemostasis was later 461.0 (420.0501.0) sec. Morphological studies have allowed us to establish differences in both the rate and quality of reparative regeneration of experimental simulated liver wounds compared with the control. Experimental studies using Molselect G-50 in combination with Surgistamp for local hemostasis of bleeding liver wounds in rabbits allowed us to conclude that such a combination makes it possible not only to reliably stop bleeding, but also promotes the stimulation of reparative regeneration.
- Open Access
- 3 April 2023
- Published by VSMU N.N. Burdenko in Journal of Experimental and Clinical Surgery
- Vol. 16 (1) , 52-59
Hemostatic Gauze Surgitamp and Granular Sorbent Molselect G-50 Application in the Treatment of Simulated Bleeding Liver Wounds
The aim of the study was to investigate the potential of Surgitamp hemostatic gauze and Molselect G-50 sorbent application in surgical hemostasis of simulated bleeding liver wounds in an in vivo experiment on laboratory animals. Materials and methods. The study included 30 laboratory animals: Chinchilla rabbits. Laboratory animals underwent median laparotomy under intravenous anesthesia (Zoletil 100 0.1 ml /kg, Xylavet 0.1 ml/kg), the right lobe of the liver was involved into the wound. At a 20 cm distance from the surface of the liver, a metal 92 g load in the form of a triangular prism was attached to the slider with the help of a thread. By operational readiness, the thread was burned, the prism fell vertically and hit the surface of the liver with a pointed end, this resulting in a simulated bleeding liver wound: a wound of the right lobe of the liver, linear in shape 3.0x0.7 cm, 0.6 cm deep, with uneven edges and active bleeding from the defect area. Hemostasis in the experimental group of animals (n=15) was carried out by covering the wound surface with a granular sorbent Molselect G-50, followed by tamponing the wound with a strip of hemostatic gauze Surgitamp. In the control group of animals (n=15) hemostasis was carried out by stitching a bleeding liver wound with a U-shaped suture with a PHA 3.0 thread until the edges of the wound converged. The effectiveness of hemostasis of the liver wounds was evaluated using the following parameters: the time of the final bleeding arrest, the volume of blood loss, the number of episodes of repeated bleeding. Results. Experimental studies have demonstrated that the surgical hemostasis technique with the hemostatic agent Surgitamp application combined with the granular sorbent Molselect G-50 allows for reliable hemostasis of simulated bleeding liver wounds, reducing the time of bleeding arrest from 461.0(420.0-501.0) sec to 280.0(264.0-308.0) sec (P=0.0001), simultaneously reducing the incidence of recurrent hemorrhages from 46.7% to 6.7% (P=0.035).
- 3 April 2023
- Published by VSMU N.N. Burdenko in Journal of Experimental and Clinical Surgery
- Vol. 16 (1) , 52-59
Open AccessHemostatic Gauze Surgitamp and Granular Sorbent Molselect G-50 Application in the Treatment of Simulated Bleeding Liver Wounds
The aim of the study was to investigate the potential of Surgitamp hemostatic gauze and Molselect G-50 sorbent application in surgical hemostasis of simulated bleeding liver wounds in an in vivo experiment on laboratory animals. Materials and methods. The study included 30 laboratory animals: Chinchilla rabbits. Laboratory animals underwent median laparotomy under intravenous anesthesia (Zoletil 100 0.1 ml /kg, Xylavet 0.1 ml/kg), the right lobe of the liver was involved into the wound. At a 20 cm distance from the surface of the liver, a metal 92 g load in the form of a triangular prism was attached to the slider with the help of a thread. By operational readiness, the thread was burned, the prism fell vertically and hit the surface of the liver with a pointed end, this resulting in a simulated bleeding liver wound: a wound of the right lobe of the liver, linear in shape 3.0x0.7 cm, 0.6 cm deep, with uneven edges and active bleeding from the defect area. Hemostasis in the experimental group of animals (n=15) was carried out by covering the wound surface with a granular sorbent Molselect G-50, followed by tamponing the wound with a strip of hemostatic gauze Surgitamp. In the control group of animals (n=15) hemostasis was carried out by stitching a bleeding liver wound with a U-shaped suture with a PHA 3.0 thread until the edges of the wound converged. The effectiveness of hemostasis of the liver wounds was evaluated using the following parameters: the time of the final bleeding arrest, the volume of blood loss, the number of episodes of repeated bleeding. Results. Experimental studies have demonstrated that the surgical hemostasis technique with the hemostatic agent Surgitamp application combined with the granular sorbent Molselect G-50 allows for reliable hemostasis of simulated bleeding liver wounds, reducing the time of bleeding arrest from 461.0(420.0-501.0) sec to 280.0(264.0-308.0) sec (P=0.0001), simultaneously reducing the incidence of recurrent hemorrhages from 46.7% to 6.7% (P=0.035).