Qi An
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Qi An has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Chenyang Xue
North University of China
3 shared publications - Junbin Zang
College of Information Engineering, Shanxi College of Technology, Shuozhou, China
3 shared publications - Daren An
School of Instrument and Electronics and the Key Laboratory of Instrumentation Science and Dynamic Measurement, North University of China, Taiyuan, China
2 shared publications - Huiliang Cao
Beijing Institute of Technology
2 shared publications - Libo Gao
Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen, 361102, China
2 shared publications - Zhidong Zhang
Key Laboratory of Instrumentation Science & Dynamic Measurement of Ministry of Education, North University of China, Taiyuan 030051, China
2 shared publications
Latest Publications
- 10 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (7) , 10685-10693
Design and Intelligent Optimization of Z-Shaped MEMS Accelerometer Structure for Heart Sound Detection
Digital heart sound auscultation technology is crucial for the early diagnosis of coronary heart disease, and the optimal structural design and parameter optimization of high-performance heart sound sensor devices can significantly enhance the quality of heart sound signal acquisition. The determination of conventional sensor structural parameters primarily relies on empirical selection based on simulation analysis results and repeated experimental validation, which is time-consuming and inefficient, making it difficult to reduce research and development cycles and costs. Based on this, this study proposes a novel Z-shaped cantilever beam accelerometer-based heart sound sensor structure and designs a PSO-BPNN optimization model that combines Particle Swarm Optimization (PSO) and Back Propagation (BP) neural networks to achieve intelligent analysis and optimization selection of the parameters for the Z-shaped cantilever beam acceleration heart sound sensing structure. The results indicate that the PSO-BPNN demonstrates extremely high accuracy in predicting the maximum stress (S) and natural frequency (F) of the sensor, with relative errors as low as 1.3% and 0.1%, respectively. Furthermore, transient simulation tests using COMSOL with heart sound interpolation signals show that the optimized Z-shaped sensor performs excellently, with an output voltage amplitude reaching 0.025V, significantly improving its response sensitivity compared to the empirical parameter structure. Therefore, this study not only enhances the efficiency of design and development while reducing empirical errors but also theoretically validates the effectiveness of intelligent analysis and design methods, laying a solid foundation for technological advancements in sensor design and the widespread application of intelligent analysis and design methods.
- 10 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (7) , 10685-10693
Design and Intelligent Optimization of Z-Shaped MEMS Accelerometer Structure for Heart Sound Detection
Digital heart sound auscultation technology is crucial for the early diagnosis of coronary heart disease, and the optimal structural design and parameter optimization of high-performance heart sound sensor devices can significantly enhance the quality of heart sound signal acquisition. The determination of conventional sensor structural parameters primarily relies on empirical selection based on simulation analysis results and repeated experimental validation, which is time-consuming and inefficient, making it difficult to reduce research and development cycles and costs. Based on this, this study proposes a novel Z-shaped cantilever beam accelerometer-based heart sound sensor structure and designs a PSO-BPNN optimization model that combines Particle Swarm Optimization (PSO) and Back Propagation (BP) neural networks to achieve intelligent analysis and optimization selection of the parameters for the Z-shaped cantilever beam acceleration heart sound sensing structure. The results indicate that the PSO-BPNN demonstrates extremely high accuracy in predicting the maximum stress (S) and natural frequency (F) of the sensor, with relative errors as low as 1.3% and 0.1%, respectively. Furthermore, transient simulation tests using COMSOL with heart sound interpolation signals show that the optimized Z-shaped sensor performs excellently, with an output voltage amplitude reaching 0.025V, significantly improving its response sensitivity compared to the empirical parameter structure. Therefore, this study not only enhances the efficiency of design and development while reducing empirical errors but also theoretically validates the effectiveness of intelligent analysis and design methods, laying a solid foundation for technological advancements in sensor design and the widespread application of intelligent analysis and design methods.
- Top Cited PapersOpen Access
- 15 January 2025
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 11 (1) , 1-13
A novel wearable device integrating ECG and PCG for cardiac health monitoring
The alarming prevalence and mortality rates associated with cardiovascular diseases have emphasized the urgency for innovative detection solutions. Traditional methods, often costly, bulky, and prone to subjectivity, fall short of meeting the need for daily monitoring. Digital and portable wearable monitoring devices have emerged as a promising research frontier. This study introduces a wearable system that integrates electrocardiogram (ECG) and phonocardiogram (PCG) detection. By ingeniously pairing a contact-type PZT heart sound sensing structure with ECG electrodes, the system achieves the acquisition of high-quality ECG and PCG signals. Notably, the signal-to-noise ratios (SNR) for ECG and PCG signals were measured at 44.13 dB and 30.04 dB, respectively, demonstrating the system’s remarkable stability across varying conditions. These collected signals were subsequently utilized to derive crucial feature values, including electromechanical delay (EMD), left ventricular ejection time (LVET), and pre-ejection period (PEP). Furthermore, we collected a dataset comprising 40 cases of ECG and PCG signals, enabling a comparative analysis of these three feature parameters between healthy individuals and coronary heart disease patients. This research endeavor presents a significant step forward in the realm of early, non-invasive, and intelligent monitoring of cardiovascular diseases, offering hope for earlier detection and more effective management of these life-threatening conditions.
- 15 January 2025
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 11 (1) , 1-13
Top Cited PapersOpen AccessA novel wearable device integrating ECG and PCG for cardiac health monitoring
The alarming prevalence and mortality rates associated with cardiovascular diseases have emphasized the urgency for innovative detection solutions. Traditional methods, often costly, bulky, and prone to subjectivity, fall short of meeting the need for daily monitoring. Digital and portable wearable monitoring devices have emerged as a promising research frontier. This study introduces a wearable system that integrates electrocardiogram (ECG) and phonocardiogram (PCG) detection. By ingeniously pairing a contact-type PZT heart sound sensing structure with ECG electrodes, the system achieves the acquisition of high-quality ECG and PCG signals. Notably, the signal-to-noise ratios (SNR) for ECG and PCG signals were measured at 44.13 dB and 30.04 dB, respectively, demonstrating the system’s remarkable stability across varying conditions. These collected signals were subsequently utilized to derive crucial feature values, including electromechanical delay (EMD), left ventricular ejection time (LVET), and pre-ejection period (PEP). Furthermore, we collected a dataset comprising 40 cases of ECG and PCG signals, enabling a comparative analysis of these three feature parameters between healthy individuals and coronary heart disease patients. This research endeavor presents a significant step forward in the realm of early, non-invasive, and intelligent monitoring of cardiovascular diseases, offering hope for earlier detection and more effective management of these life-threatening conditions.
- Open Access
- 26 November 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (12) , 1419
Range Expansion Technology for Ring MEMS Gyroscopes Based on Drive Voltage Modulation
This paper proposes a method to control the sensitivity of a ring MEMS gyroscope by adjusting the driving control voltage via MEMS. The aim is to explore the relationship between the range of the ring MEMS gyroscope and the driving control voltage, establishing a mathematical model that correlates driving control voltage with sensitivity. By applying different driving voltages to the same gyroscope, the study evaluates the performance and range of the gyroscope. Experimental results demonstrate that lower driving voltages increase the gyroscope’s range. At a driving voltage of 10.85 V, the gyroscope achieves a range of ±200°/s, a minimum resolution of 0.019°/s, and a nonlinearity of 22.37 ppm. At 1.46 V, the gyroscope range expands to ±1000°/s, with a minimum resolution of 0.05138°/s and a nonlinearity of 60.73 ppm. As the measurement range increased fivefold, the degradation in gyroscope performance was significantly less than the scale of range expansion. Compared to the gain in modulation detection circuitry, gyroscope performance was optimized across the entire operational range.
- 26 November 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (12) , 1419
Open AccessRange Expansion Technology for Ring MEMS Gyroscopes Based on Drive Voltage Modulation
This paper proposes a method to control the sensitivity of a ring MEMS gyroscope by adjusting the driving control voltage via MEMS. The aim is to explore the relationship between the range of the ring MEMS gyroscope and the driving control voltage, establishing a mathematical model that correlates driving control voltage with sensitivity. By applying different driving voltages to the same gyroscope, the study evaluates the performance and range of the gyroscope. Experimental results demonstrate that lower driving voltages increase the gyroscope’s range. At a driving voltage of 10.85 V, the gyroscope achieves a range of ±200°/s, a minimum resolution of 0.019°/s, and a nonlinearity of 22.37 ppm. At 1.46 V, the gyroscope range expands to ±1000°/s, with a minimum resolution of 0.05138°/s and a nonlinearity of 60.73 ppm. As the measurement range increased fivefold, the degradation in gyroscope performance was significantly less than the scale of range expansion. Compared to the gain in modulation detection circuitry, gyroscope performance was optimized across the entire operational range.
- 8 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (10) , 15884-15891
Design and Fabrication of Ultralow Temperature Vibration Sensor Based on Self-Excited Vibration Resonance Frequency Test
In the field of aerospace, deep space exploration is becoming more and more frequent, and the temperature deep in the universe is getting lower and lower. Specialized equipment for vibration monitoring of instruments under harsh conditions of ultra-low temperature is scarce, and how to design a vibration sensor to solve the vibration monitoring in ultra-low temperature environments is an urgent problem. In this paper, we propose a novel testing methodology known as Self-Excited Vibration Resonance Frequency Test of piezoelectric sheet in ultra-low temperature, which contributes to the ultra-low temperature survival verification of piezoelectric materials for ultra-low temperature vibration sensors. The method proves that the PZT-7A piezoelectric material can work in ultra-low temperature environments. The sensitivity of the ultra-low temperature vibration sensor was obtained by vibration test as well as temperature test to be 5.08 mV/g. It can work normally at -197°C-RT with small output signal noise. The ultra-low temperature vibration sensor designed in this paper has low cost and good low-temperature resistance. It can be widely used in structural health monitoring of instruments and equipment in ultra-low temperature environments.
- 8 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (10) , 15884-15891
Design and Fabrication of Ultralow Temperature Vibration Sensor Based on Self-Excited Vibration Resonance Frequency Test
In the field of aerospace, deep space exploration is becoming more and more frequent, and the temperature deep in the universe is getting lower and lower. Specialized equipment for vibration monitoring of instruments under harsh conditions of ultra-low temperature is scarce, and how to design a vibration sensor to solve the vibration monitoring in ultra-low temperature environments is an urgent problem. In this paper, we propose a novel testing methodology known as Self-Excited Vibration Resonance Frequency Test of piezoelectric sheet in ultra-low temperature, which contributes to the ultra-low temperature survival verification of piezoelectric materials for ultra-low temperature vibration sensors. The method proves that the PZT-7A piezoelectric material can work in ultra-low temperature environments. The sensitivity of the ultra-low temperature vibration sensor was obtained by vibration test as well as temperature test to be 5.08 mV/g. It can work normally at -197°C-RT with small output signal noise. The ultra-low temperature vibration sensor designed in this paper has low cost and good low-temperature resistance. It can be widely used in structural health monitoring of instruments and equipment in ultra-low temperature environments.
- 1 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (10) , 15865-15874
Integrated Acoustic-Vibratory Sensor Inspired by the Ear Bones of Sea Turtles for Heart Sound Detection
Biomimetics is an indispensable discipline in modern sensing technology and has been the source of inspiration for many significant inventions. Building upon the foundation of MEMS cantilever beam accelerometers, this paper combines biomimetic theory to propose an integrated MEMS acoustic-vibratory sensing structure that imitates the ear bones of sea turtles. Additionally, a novel acoustic packaging is designed based on the principle of the megaphone. Through simulation analysis, micro-nano fabrication techniques, and computer numerical control (CNC) machining, the fabrication and integration of the sensing structure are achieved. Subsequently, an acoustic testing platform is constructed for acoustic testing, and vibration testing is conducted using a vibration exciter. Experimental results demonstrate that the acoustic sensitivity of the MEMS biomimetic sensing structure can reach up to -21.926 V/Pa (re: 1 V/Pa) within the 20-200 Hz range, enabling the detection of periodic heart sound signals. Furthermore, compared to other accelerometers, the proposed biomimetic sensor exhibits significantly improved vibration sensitivity, reaching 5.3 V/g, aligning with the biomimetic mechanism of sea turtle’s ear bones. The aforementioned research provides a new solution for low-cost heart sound detection and establishes a foundation for future biomimetic theories and composite sensor technologies.
- 1 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (10) , 15865-15874
Integrated Acoustic-Vibratory Sensor Inspired by the Ear Bones of Sea Turtles for Heart Sound Detection
Biomimetics is an indispensable discipline in modern sensing technology and has been the source of inspiration for many significant inventions. Building upon the foundation of MEMS cantilever beam accelerometers, this paper combines biomimetic theory to propose an integrated MEMS acoustic-vibratory sensing structure that imitates the ear bones of sea turtles. Additionally, a novel acoustic packaging is designed based on the principle of the megaphone. Through simulation analysis, micro-nano fabrication techniques, and computer numerical control (CNC) machining, the fabrication and integration of the sensing structure are achieved. Subsequently, an acoustic testing platform is constructed for acoustic testing, and vibration testing is conducted using a vibration exciter. Experimental results demonstrate that the acoustic sensitivity of the MEMS biomimetic sensing structure can reach up to -21.926 V/Pa (re: 1 V/Pa) within the 20-200 Hz range, enabling the detection of periodic heart sound signals. Furthermore, compared to other accelerometers, the proposed biomimetic sensor exhibits significantly improved vibration sensitivity, reaching 5.3 V/g, aligning with the biomimetic mechanism of sea turtle’s ear bones. The aforementioned research provides a new solution for low-cost heart sound detection and establishes a foundation for future biomimetic theories and composite sensor technologies.