Meng Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Meng Lu has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Kai Li
College of Biological Science and Medical Engineering, Donghua University, Shanghai, China
3 shared publicationsYuxun Zhou
College of Biological Science and Medical Engineering, Donghua University, Shanghai, China
3 shared publicationsChen Tang
College of Biological Science and Medical Engineering, Donghua University, Shanghai 201620, China
2 shared publications- Junhua Xiao
College of Biological Science and Medical Engineering, Donghua University, Shanghai 201620, China
2 shared publications - Dongqing Zhao
College of Biological Science and Medical Engineering, Donghua University, Shanghai 201620, China
1 shared publication Huanhuan Zong
College of Biological Science and Medical Engineering, Donghua University, Shanghai 201620, China
1 shared publication
Latest Publications
- Open Access
- 3 October 2024
- Published by Springer Nature in BMC Genomic Data
- Vol. 25 (1) , 1-13
Identification of the genetic background of laboratory rats through amplicon-based next-generation sequencing for single-nucleotide polymorphism genotyping
Laboratory rats, as model animals, have been extensively used in the fields of life science and medicine. It is crucial to routinely monitor the genetic background of laboratory rats. The conventional approach relies on gel electrophoresis and capillary electrophoresis (CE) technologies. However, the experimental and data analysis procedures for both of these methods are time consuming and costly. We established a single-nucleotide polymorphism (SNP) typing scheme using multiplex polymerase chain reaction (PCR) and next-generation sequencing (NGS) to address the genetic background ambiguity in laboratory rats. This methodology involved three rounds of PCR and two rounds of magnetic bead selection to improve the quality of the sequencing data. We simultaneously analysed 100 laboratory rats (including rats of 5 inbred strains and 2 in-house closed colonies), and the sequencing depth varied from an average of 108.25 to 5189.89, with sample uniformity ranging from 82.5 to 97.5%. A total of 98.9% of the amplicons were successfully genotyped (≥ 30 reads). Genetic background analysis revealed that all 38 experimental rats from the 5 inbred strains were successfully identified (without a heterozygous allele). For the 2 in-house closed colonies, the average heterozygosity (0.162 and 0.169) deviated from the typical range of 0.5–0.7, indicating a departure from the ideal heterozygosity level. Additionally, we employed multiplex PCR-CE to validate the NGS-based method, which yielded consistent results for all the rat strains. These results demonstrated that this approach significantly improves efficiency, saves time, reduces costs and ensures accuracy. By utilizing NGS technology, our developed method leverages SNP genotyping for genetic background identification in laboratory rats, demonstrating advantages in terms of labour efficiency and cost-effectiveness, thereby rendering it well suited for projects involving extensive sample cohorts.
- 3 October 2024
- Published by Springer Nature in BMC Genomic Data
- Vol. 25 (1) , 1-13
Open AccessIdentification of the genetic background of laboratory rats through amplicon-based next-generation sequencing for single-nucleotide polymorphism genotyping
Laboratory rats, as model animals, have been extensively used in the fields of life science and medicine. It is crucial to routinely monitor the genetic background of laboratory rats. The conventional approach relies on gel electrophoresis and capillary electrophoresis (CE) technologies. However, the experimental and data analysis procedures for both of these methods are time consuming and costly. We established a single-nucleotide polymorphism (SNP) typing scheme using multiplex polymerase chain reaction (PCR) and next-generation sequencing (NGS) to address the genetic background ambiguity in laboratory rats. This methodology involved three rounds of PCR and two rounds of magnetic bead selection to improve the quality of the sequencing data. We simultaneously analysed 100 laboratory rats (including rats of 5 inbred strains and 2 in-house closed colonies), and the sequencing depth varied from an average of 108.25 to 5189.89, with sample uniformity ranging from 82.5 to 97.5%. A total of 98.9% of the amplicons were successfully genotyped (≥ 30 reads). Genetic background analysis revealed that all 38 experimental rats from the 5 inbred strains were successfully identified (without a heterozygous allele). For the 2 in-house closed colonies, the average heterozygosity (0.162 and 0.169) deviated from the typical range of 0.5–0.7, indicating a departure from the ideal heterozygosity level. Additionally, we employed multiplex PCR-CE to validate the NGS-based method, which yielded consistent results for all the rat strains. These results demonstrated that this approach significantly improves efficiency, saves time, reduces costs and ensures accuracy. By utilizing NGS technology, our developed method leverages SNP genotyping for genetic background identification in laboratory rats, demonstrating advantages in terms of labour efficiency and cost-effectiveness, thereby rendering it well suited for projects involving extensive sample cohorts.
- 5 September 2024
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 10 (10) , 6594-6602
Rapid Real-Time PCR Based on Core–Shell Tecto-Dendrimer-Entrapped Au Nanoparticles
Rapid real-time PCR (generally <1 h) has broad prospects. In this study, we synthesized a new type of nanomaterial core-shell tecto-dendrimer coated with Au nanoparticles (Au CSTDs) for research in this field. The experimental results showed that Au CSTDs could significantly shorten the time of real-time PCR (from 72 to 28 min) with different templates, while the detection limit reached 10 copies and the nonspecific amplification was significantly reduced. Furthermore, experimental analyses and theoretical studies using the finite element simulation method confirmed that Au CSTDs function by synergistically enhancing electrostatic adsorption and thermal conductivity. These properties play a key role in improving real-time PCR, especially in particle-particle interactions. This study contributes an advanced method to rapid real-time PCR, which is expected to remarkably improve the efficiency, lower the detection limit, and enhance the specificity of molecular detection.
- 5 September 2024
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 10 (10) , 6594-6602
Rapid Real-Time PCR Based on Core–Shell Tecto-Dendrimer-Entrapped Au Nanoparticles
Rapid real-time PCR (generally <1 h) has broad prospects. In this study, we synthesized a new type of nanomaterial core-shell tecto-dendrimer coated with Au nanoparticles (Au CSTDs) for research in this field. The experimental results showed that Au CSTDs could significantly shorten the time of real-time PCR (from 72 to 28 min) with different templates, while the detection limit reached 10 copies and the nonspecific amplification was significantly reduced. Furthermore, experimental analyses and theoretical studies using the finite element simulation method confirmed that Au CSTDs function by synergistically enhancing electrostatic adsorption and thermal conductivity. These properties play a key role in improving real-time PCR, especially in particle-particle interactions. This study contributes an advanced method to rapid real-time PCR, which is expected to remarkably improve the efficiency, lower the detection limit, and enhance the specificity of molecular detection.
- 27 March 2024
- Published by Wiley in Electrophoresis
- Vol. 45 (15-16) , 1398-1407
Low cycle number multiplex PCR: A novel strategy for the construction of amplicon libraries for next‐generation sequencing
Multiplex PCR is a critical step when preparing amplicon library for next‐generation sequencing. However, there are several challenges related to multiplex PCR including poor uniformity, nonspecific amplification, and primer–dimers. To address these issues, we propose a novel solution strategy that involves using a low cycle number (<10 cycles) in multiplex PCR and then employing carrier DNAs and magnetic beads for the selection of targeted products. This technique improves the amplicon uniformity while also reducing primer–dimers and PCR artifacts. To evaluate our technique, we initially utilized 120 DNA fragments from mouse genome containing single nucleotide polymorphism (SNP) sites. Sequencing results demonstrated that with only 7 cycles of multiplex PCR, 95.8% of the targeted SNP sites were mapped, with a coverage of at least 1×. The average sequencing depth of all amplicons was 1705.79 ± 1205.30×; 87% of them reached a coverage depth that exceeded 0.2‐fold of the average sequencing depth. Our method had a greater uniformity (87%) when compared to Hi‐Plex PCR (53.3%). Furthermore, we validated our strategy by randomly selecting 90 primer pairs twice from the initial set of 120 primer‐pairs. Next, we used the same protocol to prepare amplicon libraries. The two groups had an average sequencing depth of 1013.30 ± 585.57× and 219.10 ± 158.27×, respectively; over 84% of the amplicons had a sequencing depth that exceeded 0.2‐fold of average depth. These results suggest that the use of a low cycle number in multiplex PCR is a cost‐effective and efficient approach for the preparation of amplicon libraries.
- 27 March 2024
- Published by Wiley in Electrophoresis
- Vol. 45 (15-16) , 1398-1407
Low cycle number multiplex PCR: A novel strategy for the construction of amplicon libraries for next‐generation sequencing
Multiplex PCR is a critical step when preparing amplicon library for next‐generation sequencing. However, there are several challenges related to multiplex PCR including poor uniformity, nonspecific amplification, and primer–dimers. To address these issues, we propose a novel solution strategy that involves using a low cycle number (<10 cycles) in multiplex PCR and then employing carrier DNAs and magnetic beads for the selection of targeted products. This technique improves the amplicon uniformity while also reducing primer–dimers and PCR artifacts. To evaluate our technique, we initially utilized 120 DNA fragments from mouse genome containing single nucleotide polymorphism (SNP) sites. Sequencing results demonstrated that with only 7 cycles of multiplex PCR, 95.8% of the targeted SNP sites were mapped, with a coverage of at least 1×. The average sequencing depth of all amplicons was 1705.79 ± 1205.30×; 87% of them reached a coverage depth that exceeded 0.2‐fold of the average sequencing depth. Our method had a greater uniformity (87%) when compared to Hi‐Plex PCR (53.3%). Furthermore, we validated our strategy by randomly selecting 90 primer pairs twice from the initial set of 120 primer‐pairs. Next, we used the same protocol to prepare amplicon libraries. The two groups had an average sequencing depth of 1013.30 ± 585.57× and 219.10 ± 158.27×, respectively; over 84% of the amplicons had a sequencing depth that exceeded 0.2‐fold of average depth. These results suggest that the use of a low cycle number in multiplex PCR is a cost‐effective and efficient approach for the preparation of amplicon libraries.