Jonas Pfaff
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jonas Pfaff has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Luciano Melo Silva
Institute of Biology, Graz University ; Institute of Botany, Ulm University
2 shared publications - Luciano Pereira
Institute of Botany Ulm University Albert‐Einstein‐Allee 11 89081 Ulm Germany
2 shared publications - Steven Jansen
Institute of Botany, Ulm University
2 shared publications - Alexander Rack
ESRF – The European Synchrotron, Grenoble, France
1 shared publication - Charlie Kirchner-Burles
University College London
1 shared publication - Christophe Lionel Trabi
Nottingham Trent Univ. (United Kingdom)
1 shared publication
Latest Publications
- Open Access
- 9 August 2024
- Published by Wiley in Plant, Cell & Environment
- Vol. 47 (12) , 4977-4991
The potential link between gas diffusion and embolism spread in angiosperm xylem: Evidence from flow‐centrifuge experiments and modelling
Understanding xylem embolism formation is challenging due to dynamic changes and multiphase interactions in conduits. Here, we hypothesise that embolism spread involves gas diffusion in xylem, and is affected by time. We measured hydraulic conductivity (Kh) in flow‐centrifuge experiments over 1 h at a given pressure and temperature for stem samples of three angiosperm species. Temporal changes in Kh at 5, 22, and 35°C, and at various pressures were compared to modelled gas concentration changes in a recently embolised vessel in the centre of a centrifuge sample. Temporal changes in Kh were logarithmic and species‐specific. Maximum relative increases of Kh between 6% and 40% happened at 22°C for low centrifugal speed (h were experimentally shown to be associated with a temporal increase of embolism at the centre of centrifuge samples, which was likely associated with gas concentration increases in recently embolized vessels. Although embolism is mostly pressure‐driven, our experimental and modelled data indicate that time, conduit characteristics, and temperature are involved due to their potential role in gas diffusion. Gas diffusion, however, does not seem to cover the entire process of embolism spread.
- 9 August 2024
- Published by Wiley in Plant, Cell & Environment
- Vol. 47 (12) , 4977-4991
Open AccessThe potential link between gas diffusion and embolism spread in angiosperm xylem: Evidence from flow‐centrifuge experiments and modelling
Understanding xylem embolism formation is challenging due to dynamic changes and multiphase interactions in conduits. Here, we hypothesise that embolism spread involves gas diffusion in xylem, and is affected by time. We measured hydraulic conductivity (Kh) in flow‐centrifuge experiments over 1 h at a given pressure and temperature for stem samples of three angiosperm species. Temporal changes in Kh at 5, 22, and 35°C, and at various pressures were compared to modelled gas concentration changes in a recently embolised vessel in the centre of a centrifuge sample. Temporal changes in Kh were logarithmic and species‐specific. Maximum relative increases of Kh between 6% and 40% happened at 22°C for low centrifugal speed (h were experimentally shown to be associated with a temporal increase of embolism at the centre of centrifuge samples, which was likely associated with gas concentration increases in recently embolized vessels. Although embolism is mostly pressure‐driven, our experimental and modelled data indicate that time, conduit characteristics, and temperature are involved due to their potential role in gas diffusion. Gas diffusion, however, does not seem to cover the entire process of embolism spread.
- Open Access
Time-based shifts in xylem vulnerability curves of angiosperms based on the flow-centrifuge method
Centrifuges provide a fast and standard approach to quantify embolism resistance of xylem in vulnerability curves (VCs). Traditionally, embolism formation in centrifuge experiments is assumingly driven by centrifuge speed, and thus pressure, but unaffected by spin time. Here, we explore to what extent embolism resistance is not only pressure but also spin time dependent, and hypothesise that time-stable hydraulic conductivity (K h ) values could shift VCs. We quantified time-based shifts in flow- centrifuge VCs and their parameter estimations for six angiosperm species by measuring K h at regular intervals over 15 minutes of spinning at a particular speed before a higher speed was applied to the same sample. We compared various VCs per sample based on cumulative spin time, and modelled the relationship between K h , xylem water potential (Ψ), and spin time. Time-based changes of K h showed considerable increases and decreases at low and high centrifuge speeds, respectively, which generally shifted VCs towards more positive Ψ values. Values corresponding to 50% loss of hydraulic conductivity ( P 50 ) increased up to 0.72 MPa in Acer pseudoplatanus , and on average by 8.5% for all six species compared to VCs that did not consider spin time. By employing an asymptotic exponential model, we estimated time-stable K h , which improved the statistical significance of VCs in 5 of the 6 species studied. This model also revealed the instability of VCs at short spin times, and showed that embolism formation in flow-centrifuges followed a saturating exponential growth curve. Although pressure remains the major determinant of embolism formation, spin time should be considered in flow- centrifuge VCs to avoid overestimation of embolism resistance. This spin-time artefact is species- specific, and likely based on relatively slow gas diffusion associated with embolism spreading. It can be minimized by determining time-stable K h values for each centrifuge speed, without considerably extending the experimental time to construct VCs.
Open AccessTime-based shifts in xylem vulnerability curves of angiosperms based on the flow-centrifuge method
Centrifuges provide a fast and standard approach to quantify embolism resistance of xylem in vulnerability curves (VCs). Traditionally, embolism formation in centrifuge experiments is assumingly driven by centrifuge speed, and thus pressure, but unaffected by spin time. Here, we explore to what extent embolism resistance is not only pressure but also spin time dependent, and hypothesise that time-stable hydraulic conductivity (K h ) values could shift VCs. We quantified time-based shifts in flow- centrifuge VCs and their parameter estimations for six angiosperm species by measuring K h at regular intervals over 15 minutes of spinning at a particular speed before a higher speed was applied to the same sample. We compared various VCs per sample based on cumulative spin time, and modelled the relationship between K h , xylem water potential (Ψ), and spin time. Time-based changes of K h showed considerable increases and decreases at low and high centrifuge speeds, respectively, which generally shifted VCs towards more positive Ψ values. Values corresponding to 50% loss of hydraulic conductivity ( P 50 ) increased up to 0.72 MPa in Acer pseudoplatanus , and on average by 8.5% for all six species compared to VCs that did not consider spin time. By employing an asymptotic exponential model, we estimated time-stable K h , which improved the statistical significance of VCs in 5 of the 6 species studied. This model also revealed the instability of VCs at short spin times, and showed that embolism formation in flow-centrifuges followed a saturating exponential growth curve. Although pressure remains the major determinant of embolism formation, spin time should be considered in flow- centrifuge VCs to avoid overestimation of embolism resistance. This spin-time artefact is species- specific, and likely based on relatively slow gas diffusion associated with embolism spreading. It can be minimized by determining time-stable K h values for each centrifuge speed, without considerably extending the experimental time to construct VCs.
- 10 July 2023
- Published by Elsevier in Journal of Energy Storage
- Vol. 71, 108088
Sidewall breach during lithium-ion battery thermal runaway triggered by cell-to-cell propagation visualized using high-speed X-ray imaging
- 10 July 2023
- Published by Elsevier in Journal of Energy Storage
- Vol. 71, 108088
Sidewall breach during lithium-ion battery thermal runaway triggered by cell-to-cell propagation visualized using high-speed X-ray imaging