Chiyo Shimizu-Tomoda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chiyo Shimizu-Tomoda has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Aiko Ishizaki-Terauchi
Department of Orthodontic Science, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
2 shared publications - Makiko Okuzawa-Iwasaki
Department of Orthodontic Science, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo (Science Tokyo), Tokyo 113-8549, Japan
2 shared publications - Takashi Ono
Institute of Science Tokyo
2 shared publications - Yuji Ishida
Department of Orthodontic Science, Graduate School of Medical and Dental Sciences Institute of Science Tokyo Japan
2 shared publications - Jun Aida
Department of Dental Public Health, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo, Japan
1 shared publication
Latest Publications
- Open Access
- 25 November 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (23)
Relationship Between Laterality of Orthodontic Miniscrew Failure and Clinical Variables
Background/Objectives: Many reports on orthodontic miniscrew insertion focus on insertion conditions, such as technique, but not on the insertion environment, such as the operator’s dominant hand. This study aimed to ascertain whether the operator’s dominant hand affects laterality in the success rate of manual and motorized miniscrew insertion methods. Methods: This study retrospectively investigated the medical records of 250 Japanese patients, aged ≥15 years, who underwent miniscrew implantation in the maxilla by right-handed operators with at least 3 years of experience. A cross-tabulation analysis, Chi-square test, and multiple logistic regression analysis were performed to compare the success rates of the two insertion methods. Results: A total of 454 screws were implanted (346 manual and 108 motorized), with an overall success rate of 79.2%. No significant difference was observed in the success rate between the manual (77.7%) and motorized groups (84.2%). Regarding the laterality of the overall success rate, the right-side success rate (84.1%) was significantly higher than that of the left side (75.6%). The right-side success rate in the manual group (82.7%) was significantly higher than that of the left-side (73.0%). In the motorized group, no significant difference was observed between the success rate of insertion on the right (84.6%) and left sides (83.9%). Multiple regression analysis showed that the miniscrew insertion stability was influenced by the insertion side and the operator’s years of experience. Conclusions: The manual screw insertion method was susceptible to environmental factors and less successful in left-side insertion by right-handed operators.
- 25 November 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (23)
Open AccessRelationship Between Laterality of Orthodontic Miniscrew Failure and Clinical Variables
Background/Objectives: Many reports on orthodontic miniscrew insertion focus on insertion conditions, such as technique, but not on the insertion environment, such as the operator’s dominant hand. This study aimed to ascertain whether the operator’s dominant hand affects laterality in the success rate of manual and motorized miniscrew insertion methods. Methods: This study retrospectively investigated the medical records of 250 Japanese patients, aged ≥15 years, who underwent miniscrew implantation in the maxilla by right-handed operators with at least 3 years of experience. A cross-tabulation analysis, Chi-square test, and multiple logistic regression analysis were performed to compare the success rates of the two insertion methods. Results: A total of 454 screws were implanted (346 manual and 108 motorized), with an overall success rate of 79.2%. No significant difference was observed in the success rate between the manual (77.7%) and motorized groups (84.2%). Regarding the laterality of the overall success rate, the right-side success rate (84.1%) was significantly higher than that of the left side (75.6%). The right-side success rate in the manual group (82.7%) was significantly higher than that of the left-side (73.0%). In the motorized group, no significant difference was observed between the success rate of insertion on the right (84.6%) and left sides (83.9%). Multiple regression analysis showed that the miniscrew insertion stability was influenced by the insertion side and the operator’s years of experience. Conclusions: The manual screw insertion method was susceptible to environmental factors and less successful in left-side insertion by right-handed operators.
- Open Access
- 4 April 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (7) , 3041
Contributions of Alveolar Bone Density and Habitual Chewing Side to the Unilateral Failure of Orthodontic Mini-Screws: A Cross-Sectional Study
This study aimed to analyze the relationship between bone density, habitual chewing side (HCS), and mini-screw stability to investigate the intra-individual factors contributing to mini-screw failure. This retrospective study included 86 sides in 43 adults, who underwent bilateral maxillary mini-screw placement with subsequent unilateral failure of the mini-screw. Pre-treatment cone-beam computed tomography was used to measure the buccal cortical bone thickness and bone density on the failed and successful sides. Pre-treatment mandibular kinesiographic records were used to determine the HCS. Paired t-tests, one-proportion z-tests, and multivariable multilevel Poisson regression were used to examine the statistical significance. The buccal cortical bone thicknesses were 0.93 ± 0.27 mm (unsuccessful side) and 1.01 ± 0.27 mm (successful side), with no significant difference. The bone density on the unsuccessful side (1059.64 ± 202.64 mg/cm3) was significantly lower than the success side (1317.89 ± 332.23 mg/cm3). Regarding HCS, 27.9% of failures occurred on the preferred side, and 62.8% occurred on the non-preferred side. After adjusting for all factors, the non-preferred side showed a 2.22 times higher prevalence ratio for mini-screw failure than the preferred side. HCS is significantly related to mini-screw stability, while the cortical bone thickness, bone density, and site of mini-screw implantation were not correlated.
- 4 April 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (7) , 3041
Open AccessContributions of Alveolar Bone Density and Habitual Chewing Side to the Unilateral Failure of Orthodontic Mini-Screws: A Cross-Sectional Study
This study aimed to analyze the relationship between bone density, habitual chewing side (HCS), and mini-screw stability to investigate the intra-individual factors contributing to mini-screw failure. This retrospective study included 86 sides in 43 adults, who underwent bilateral maxillary mini-screw placement with subsequent unilateral failure of the mini-screw. Pre-treatment cone-beam computed tomography was used to measure the buccal cortical bone thickness and bone density on the failed and successful sides. Pre-treatment mandibular kinesiographic records were used to determine the HCS. Paired t-tests, one-proportion z-tests, and multivariable multilevel Poisson regression were used to examine the statistical significance. The buccal cortical bone thicknesses were 0.93 ± 0.27 mm (unsuccessful side) and 1.01 ± 0.27 mm (successful side), with no significant difference. The bone density on the unsuccessful side (1059.64 ± 202.64 mg/cm3) was significantly lower than the success side (1317.89 ± 332.23 mg/cm3). Regarding HCS, 27.9% of failures occurred on the preferred side, and 62.8% occurred on the non-preferred side. After adjusting for all factors, the non-preferred side showed a 2.22 times higher prevalence ratio for mini-screw failure than the preferred side. HCS is significantly related to mini-screw stability, while the cortical bone thickness, bone density, and site of mini-screw implantation were not correlated.