Prashant Gunjavate
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Prashant Gunjavate has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Abhijeet N. Kore
Department of Mechanical Engineering, Pimpri Chinchwad College of Engineering Savitribai Phule Pune University Pune Maharashtra India
2 shared publications - Rajvardhan Mane
Department of Mechanical Engineering, K E Society's, Rajarambapu Institute of Technology, Rajaramnagar Shivaji University Kolhapur Maharashtra India
1 shared publication Sachin Sawant
Shivaji University Kolhapur India
1 shared publicationSanjay Kadam
Department of Mechanical Engineering, K E Society's, Rajarambapu Institute of Technology, Rajaramnagar Shivaji University Kolhapur Maharashtra India
1 shared publication- Sanjay Kadam
Department of Mechanical Engineering, Rajarambapu Institute of Technology, Rajaramnagar, 415414, Maharashtra, India
1 shared publication Sanjaykumar S. Gawade
Mechanical Engineering Department K. E. Society's, Rajarambapu Institute of Technology (Affiliated to Shivaji University Kolhapur, Maharashtra, India) Rajaramnagar, Islampur Maharashtra India
1 shared publication
Latest Publications
- 9 October 2026
- Published by Wiley in Heat Transfer
Heat Transfer Enhancement in a Concentric Tube Heat Exchanger Using Dual‐Side Helical Wire Coil Inserts: A Numerical Study With Experimental Validation
Heat exchangers are extensively used in chemical processing, power generation, food processing, HVAC systems, and energy recovery applications, where improving thermal performance without major equipment modification is highly desirable. This study investigates the use of helical wire coil inserts as a passive enhancement technique for improving the performance of a concentric tube heat exchanger operating under turbulent flow conditions. Three configurations were analyzed: a smooth heat exchanger, a heat exchanger fitted with an inner‐tube coil, and a dual‐enhanced configuration incorporating helical wire coils on both the tube side and annulus side. The coil geometries were obtained by scaling the optimum dimensionless ratios ( e / D = 0.036 and p / D = 0.86) reported in previous single‐tube investigations, resulting in a 0.5 mm wire diameter with 12 mm pitch for the 14 mm inner tube and a 1.0 mm wire diameter with 24 mm pitch for the annulus. A three‐dimensional CFD model was developed and validated against experimental data obtained from the smooth heat exchanger, with outlet temperature deviations below 0.1%. Simulations were performed at Reynolds numbers of approximately 5000, 5500, and 6000. The inner‐tube coil increased the hot‐side Nusselt number by 31%–32% and heat exchanger effectiveness by 26%–27% compared with the smooth configuration. When an additional annulus‐side coil was introduced, the hot‐side and cold‐side Nusselt numbers increased by 40%–41% and 41%–43%, respectively, while effectiveness improved by 33%–34%. The annulus‐side thermo‐hydraulic performance factor remained above unity (1.19–1.65), indicating a favorable balance between heat transfer (HT) enhancement and pressure drop penalty. The results demonstrate that dual‐side wire coil enhancement provides significant thermal performance improvement and can be adopted as a practical retrofit solution for industrial heat exchangers requiring increased heat recovery, reduced equipment size, and improved energy efficiency without major structural modification.
- 9 October 2026
- Published by Wiley in Heat Transfer
Heat Transfer Enhancement in a Concentric Tube Heat Exchanger Using Dual‐Side Helical Wire Coil Inserts: A Numerical Study With Experimental Validation
Heat exchangers are extensively used in chemical processing, power generation, food processing, HVAC systems, and energy recovery applications, where improving thermal performance without major equipment modification is highly desirable. This study investigates the use of helical wire coil inserts as a passive enhancement technique for improving the performance of a concentric tube heat exchanger operating under turbulent flow conditions. Three configurations were analyzed: a smooth heat exchanger, a heat exchanger fitted with an inner‐tube coil, and a dual‐enhanced configuration incorporating helical wire coils on both the tube side and annulus side. The coil geometries were obtained by scaling the optimum dimensionless ratios ( e / D = 0.036 and p / D = 0.86) reported in previous single‐tube investigations, resulting in a 0.5 mm wire diameter with 12 mm pitch for the 14 mm inner tube and a 1.0 mm wire diameter with 24 mm pitch for the annulus. A three‐dimensional CFD model was developed and validated against experimental data obtained from the smooth heat exchanger, with outlet temperature deviations below 0.1%. Simulations were performed at Reynolds numbers of approximately 5000, 5500, and 6000. The inner‐tube coil increased the hot‐side Nusselt number by 31%–32% and heat exchanger effectiveness by 26%–27% compared with the smooth configuration. When an additional annulus‐side coil was introduced, the hot‐side and cold‐side Nusselt numbers increased by 40%–41% and 41%–43%, respectively, while effectiveness improved by 33%–34%. The annulus‐side thermo‐hydraulic performance factor remained above unity (1.19–1.65), indicating a favorable balance between heat transfer (HT) enhancement and pressure drop penalty. The results demonstrate that dual‐side wire coil enhancement provides significant thermal performance improvement and can be adopted as a practical retrofit solution for industrial heat exchangers requiring increased heat recovery, reduced equipment size, and improved energy efficiency without major structural modification.
- 18 April 2025
- Published by Wiley in Journal of Food Process Engineering
- Vol. 48 (4)
Feasibility of Liquid Desiccant Dehumidification System for Low‐Temperature Drying Applications
This study analyses the feasibility of a LDD system for the drying process of vegetables and fruits. An experimental setup was fabricated to observe the correlation between the relative humidity and airflow velocity. In this investigation, the influence of airflow velocity on relative humidity at the outlet and the moisture extraction rate is analyzed. Results indicate that an increase in air velocity enhances the drop in relative humidity, which is very essential for the drying of products. However, beyond a particular limit of air velocity, the moisture extraction rate demonstrates a decrease. This decrease is due to the diminishing quantity of liquid desiccant solution necessary in relation to the escalating air velocity. Achieving a relative humidity of 25.66% requires a temperature rise of 34.8°C in the convective system, while the LDD system achieves the same with a lower temperature rise of 32.2°C under identical inlet conditions. This indicates that the LDD system provides better drying conditions compared to conventional methods. Hence, the LDD system proves to be superior in preserving quality, texture, and other essential properties of perishable products in the drying process. These findings contribute to the usefulness of the LDD system for drying operations at low temperatures.
- 18 April 2025
- Published by Wiley in Journal of Food Process Engineering
- Vol. 48 (4)
Feasibility of Liquid Desiccant Dehumidification System for Low‐Temperature Drying Applications
This study analyses the feasibility of a LDD system for the drying process of vegetables and fruits. An experimental setup was fabricated to observe the correlation between the relative humidity and airflow velocity. In this investigation, the influence of airflow velocity on relative humidity at the outlet and the moisture extraction rate is analyzed. Results indicate that an increase in air velocity enhances the drop in relative humidity, which is very essential for the drying of products. However, beyond a particular limit of air velocity, the moisture extraction rate demonstrates a decrease. This decrease is due to the diminishing quantity of liquid desiccant solution necessary in relation to the escalating air velocity. Achieving a relative humidity of 25.66% requires a temperature rise of 34.8°C in the convective system, while the LDD system achieves the same with a lower temperature rise of 32.2°C under identical inlet conditions. This indicates that the LDD system provides better drying conditions compared to conventional methods. Hence, the LDD system proves to be superior in preserving quality, texture, and other essential properties of perishable products in the drying process. These findings contribute to the usefulness of the LDD system for drying operations at low temperatures.
- 4 April 2024
- Published by IOP Publishing in Engineering Research Express
- Vol. 6 (2) , 025503
Enhancing battery cell safety and lifespan through strategic application of insulating and phase change materials utilizing critical thickness for enhanced heat transfer
Efficient and secure operation of electric vehicles relies significantly on the cooling system for lithium iron phosphate (LiFePO4) batteries, a key component in electric vehicle technology. One of the critical challenges faced by electric vehicle is battery cooling to ensure optimal performance, extended battery life, and enhanced safety. The excessive heat generated during battery operation can lead to decrease in performance and potential safety hazards. Conventional cooling systems, such as air or liquid cooling, have limitations in terms of their cooling capacity, weight, and complexity. Therefore, there is a need to explore innovative cooling techniques that can effectively reduce the thermal issues associated with Electric Vehicles LiFePO4 batteries. Employing a thermal insulating coating and phase change material at the critical thickness emerges as an innovative approach to mitigate the surface temperature of battery cells. This is evident during the charging phase, where the bare cell, Teflon-insulated, and paraffin wax-coated cells reached respective peak temperatures of 69 °C, 57 °C, and 53.3 °C. Notably, the Teflon-coated cell exhibited a 17.39% reduction in peak temperature compared to the bare cell, while the paraffin wax-coated cell displayed a more substantial 23.18% reduction. A similar temperature reduction trend is observed during the discharging phase of the battery cell. Utilizing insulating materials or phase change materials with a critical thickness significantly lowers surface temperatures, enhancing the safety of the battery cell and ensuring prolonged life.
- 4 April 2024
- Published by IOP Publishing in Engineering Research Express
- Vol. 6 (2) , 025503
Enhancing battery cell safety and lifespan through strategic application of insulating and phase change materials utilizing critical thickness for enhanced heat transfer
Efficient and secure operation of electric vehicles relies significantly on the cooling system for lithium iron phosphate (LiFePO4) batteries, a key component in electric vehicle technology. One of the critical challenges faced by electric vehicle is battery cooling to ensure optimal performance, extended battery life, and enhanced safety. The excessive heat generated during battery operation can lead to decrease in performance and potential safety hazards. Conventional cooling systems, such as air or liquid cooling, have limitations in terms of their cooling capacity, weight, and complexity. Therefore, there is a need to explore innovative cooling techniques that can effectively reduce the thermal issues associated with Electric Vehicles LiFePO4 batteries. Employing a thermal insulating coating and phase change material at the critical thickness emerges as an innovative approach to mitigate the surface temperature of battery cells. This is evident during the charging phase, where the bare cell, Teflon-insulated, and paraffin wax-coated cells reached respective peak temperatures of 69 °C, 57 °C, and 53.3 °C. Notably, the Teflon-coated cell exhibited a 17.39% reduction in peak temperature compared to the bare cell, while the paraffin wax-coated cell displayed a more substantial 23.18% reduction. A similar temperature reduction trend is observed during the discharging phase of the battery cell. Utilizing insulating materials or phase change materials with a critical thickness significantly lowers surface temperatures, enhancing the safety of the battery cell and ensuring prolonged life.