Tyler Klein
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tyler Klein has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Neuber
Center for Pulsed Power and Power Electronics, Texas Tech University, Lubbock, TX 79409, USA
2 shared publications - James Dickens
Center for Pulsed Power and Power Electronics, Texas Tech University, Lubbock, TX 79409, USA
2 shared publications Andrew Eulenbach
Center for Pulsed Power and Power Electronics, Department of Electrical and Computer Engineering, Texas Tech University , Lubbock, Texas 79409, USA
1 shared publication- D. Wright
Center for Pulsed Power and Power Electronics, Texas Tech University , Lubbock, Texas 79409, USA
1 shared publication - Jacob Stephens
Center for Pulsed Power and Power Electronics, Texas Tech University, Lubbock, TX 79409, USA
1 shared publication - John Mankowski
Center for Pulsed Power and Power Electronics, Texas Tech University, Lubbock, TX 79409, USA
1 shared publication
Latest Publications
- Open Access
- 1 June 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (6)
Assessing nanocrystalline pulsed transformer core performance using Maxwell ANSYS
This paper employs the commercial simulation software ANSYS Maxwell to explore the fast-rise short-pulse magnetic properties of Finemet nanocrystalline cores, specifically FT-3KL and FT-3KM, under high magnetization rates (>0.5 T/μs) in pulsed power applications. This study aims to leverage ANSYS’s modeling capability to simulate core behavior under high magnetization rates by comparing the simulations’ saturation characteristics and B–H curve responses with experimental results. A custom solid-state pulse generator excites the cores with quasi-square pulses, featuring ∼20 ns rise time and microsecond duration, with a voltage sweep ranging from 500 to 1500 V amplitude. The simulations integrated an external circuit model with the magnetic transient solver. Both homogeneous and laminated core configurations were modeled to investigate the effects of conductivity and core geometry on flux diffusion and saturation. It was observed that an effective conductivity of 5 S/m yielded results reasonably consistent with experimental data. This research highlights the critical need for precise simulation of core behavior at high magnetization rates for fast pulsed power systems and sheds light on the limitations of a commercial simulation tool.
- 1 June 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (6)
Open AccessAssessing nanocrystalline pulsed transformer core performance using Maxwell ANSYS
This paper employs the commercial simulation software ANSYS Maxwell to explore the fast-rise short-pulse magnetic properties of Finemet nanocrystalline cores, specifically FT-3KL and FT-3KM, under high magnetization rates (>0.5 T/μs) in pulsed power applications. This study aims to leverage ANSYS’s modeling capability to simulate core behavior under high magnetization rates by comparing the simulations’ saturation characteristics and B–H curve responses with experimental results. A custom solid-state pulse generator excites the cores with quasi-square pulses, featuring ∼20 ns rise time and microsecond duration, with a voltage sweep ranging from 500 to 1500 V amplitude. The simulations integrated an external circuit model with the magnetic transient solver. Both homogeneous and laminated core configurations were modeled to investigate the effects of conductivity and core geometry on flux diffusion and saturation. It was observed that an effective conductivity of 5 S/m yielded results reasonably consistent with experimental data. This research highlights the critical need for precise simulation of core behavior at high magnetization rates for fast pulsed power systems and sheds light on the limitations of a commercial simulation tool.
- Open Access
- 1 April 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (4)
Microsecond fast, battery powered, 100 kV modular pulse charger utilizing pulse transformers
Multiple pulse charging modules were designed and tested for synchronous use in scaled experiments. The pulse chargers are each capable of charging a nanofarad-sized capacitive load to 100 kV in less than 10 µs. This is achieved by initially charging a microfarad-sized capacitor to a maximum of 3 kV, then, using a thyristor switch, discharging the capacitor into two transformers paralleled on the primary side. Each transformer steps the voltage up to 50 kV, with the transformer having opposing polarities and a common neutral on the secondary. Thus, the full 100 kV is obtained by placing the nanofarad-sized capacitor between the +50 and −50 kV terminals. The pulse chargers use a microcontroller to monitor and control the pulse charger in addition to communicating with the user as well as other pulse chargers. For increased battery life, each pulse charger is kept in a low-power state while not in use. Upon startup, the pulse chargers automatically detect the number of modules in the system, the position of itself in the system, and the timing delays associated with each pulse charger in the system. This information is essential for synchronous charging and provides individual information and controls for the pulse chargers.
- 1 April 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (4)
Open AccessMicrosecond fast, battery powered, 100 kV modular pulse charger utilizing pulse transformers
Multiple pulse charging modules were designed and tested for synchronous use in scaled experiments. The pulse chargers are each capable of charging a nanofarad-sized capacitive load to 100 kV in less than 10 µs. This is achieved by initially charging a microfarad-sized capacitor to a maximum of 3 kV, then, using a thyristor switch, discharging the capacitor into two transformers paralleled on the primary side. Each transformer steps the voltage up to 50 kV, with the transformer having opposing polarities and a common neutral on the secondary. Thus, the full 100 kV is obtained by placing the nanofarad-sized capacitor between the +50 and −50 kV terminals. The pulse chargers use a microcontroller to monitor and control the pulse charger in addition to communicating with the user as well as other pulse chargers. For increased battery life, each pulse charger is kept in a low-power state while not in use. Upon startup, the pulse chargers automatically detect the number of modules in the system, the position of itself in the system, and the timing delays associated with each pulse charger in the system. This information is essential for synchronous charging and provides individual information and controls for the pulse chargers.