MOMaksim P. Onishchenko

Maksim P. Onishchenko

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Maksim P. Onishchenko has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Retrospective analysis of safety and diagnostic efficacy of CT-guided robotic-assisted transthoracic lung biopsies

    by A.K. Chekini, I.L. Andreytsev, K.S. Titov, S.S. Lebedev, D.N. Grekov, M.P. Onishchenko, V.N. Yakomaskin, V.B. Rumer, E.YU. Neretin, R.A. Mkrtumyan

    Objective. To analyze the safety and diagnostic value of transthoracic robot-assisted CT-guided lung tumor biopsy. Material and methods. A retrospective analysis of 537 biopsy procedures in patients with solid lung lesions ≥1 cm in diameter was conducted. Biopsies were performed under synchronized multislice CT guidance using the PERFINT MAXIO robotic navigation system. The yield of informative material, diagnostic parameters (sensitivity, specificity, accuracy), and complications assessed using the Clavien-Dindo scale were assessed. Results. Informative material was obtained in 91.8% of cases (493/537). The sensitivity of the method in verifying malignant tumors was 93.9% (95% CI 91.2—96.0%), specificity was 100% (95% CI 96.3—100%), accuracy was 95.1% (95% CI 92.9—96.8%). Complications developed in 15.5% of patients (83 patients): pneumothorax — in 11.0% (59 patients), of which drainage of the pleural cavity was required in 83.1% of cases (49 patients); hemothorax — in 2.8% (15 patients); hemoptysis — in 1.7% (9 patients). Complications of I-II degree (not requiring invasive interventions) were registered in 6.3% of patients. There were no fatal outcomes. No statistically significant differences in complication rates or diagnostic efficacy were found between 16G and 18G needles. Conclusion. CT-guided transthoracic robotic-assisted biopsy demonstrates high diagnostic accuracy (95.1%) and an acceptable safety profile, allowing it to be recommended for the verification of malignant lung tumors.

  • Open Access

    Local Kidney Hyperplasia as an Aberrant Lobule: Complexity of CT-Differential Diagnosis with Clear-Celled Renal Tumor

    by A. V. Arablinskii, O. P. Myasnyankina, M. P. Onischenko, A. A. Sedova

    Report of a clinical case demonstrating aberrant hyperplastic renal lobule. The mass of the lower third of the left kidney revealed in the patient at the residential prophylactic medical examination at an ultrasound. The patient was sent to oncourology hospital with suspected renal tumor for a consultation and possible treatment. The contrast-enhanced MSCT of the abdomen was performed and it revealed soft tissue mass with pronounced and uneven enhancement in the cortico-medullary and parenchymal phase, with the subsequent gradual reduction of enhancement in the excretion phase. This resulted in left kidney resection. A resection of the kidney with tumor formation is performed within safe tissues. Later, taking into the account all clinical-morphological data the removed tumor-like node in the left kidney was characterized as an abnormality in the development of the kidney in the form of an aberrant hyperplastic renal lobule. In general, it can be considered that a correct preoperative and intraoperative diagnosis in this observation was practically difficult and even impossible. That is why the definitive diagnosis was only determined by pathomorphological study of the resected macrosection. This case demonstrates the difficulty of preoperative diagnosing. This clinical case demonstrates the complexity of pre-operative diagnosis of an extremely sparse and rarely described in the world literature anomaly of the development of urogenital system — local kidney hyperplasia. The possibilities of modern diagnostic methods are limited in differential diagnosis of this anomaly with malignant kidney tumors. In this situation we were able to isolate a single indirect sign of local hyperplasia: the prolapse of the medullary layer of the kidney into the formation.

  • Open Access

    Experience of Computer Tomography Guided Robot-Assisted Transthoracic Lung Biopsy

    by Zurab A. Bagateliya, Dmitrii N. Grekov, Sergey S. Lebedev, Antonio K. Chekini, Victor N. Yakomaskin, Vladislav E. Bugaev, Radik A. Mkrtumyan, Konstantin S. Titov, Maksim P. Onishchenko, Veronika B. Rumer, et al.

    BACKGROUND: The sensitivity of computer tomography (CT) guided transthoracic needle biopsy for the verification of lung tumors is reported to range from 74 to 90%. An augmented reality robotic navigation system for CT-guided percutaneous lung biopsy has been developed to facilitate more precise biopsy of lung lesions. The present study describes the authors’ experience with the navigation system for transthoracic lung biopsy. AIM: To analyze the safety and diagnostic value of performing a transthoracic biopsy of lung tumors using a robotic CT navigation system. MATERIALS AND METHODS: The study included a retrospective analysis of CT-guided robot-assisted transthoracic lung biopsy procedures performed in the Thoracic and Abdominal Surgical Oncology Department No. 72 of the Botkin Moscow General Scientific and Clinical Center between November 30, 2023 to April 04, 2024. A total of 104 patients were included in the study. The biopsy was performed following the developed algorithm. RESULTS: The specimens obtained were morphologically valuable in 91.8% of cases (n=101/110). A total of 1–4 specimens (tissue columns) were obtained from each patient during the biopsy procedure. Specifically, 1 specimen was obtained from 7 patients (6.4٪), 2 specimens from 57 patients (51.8٪), 3 specimens from 43 patients, and 4 specimens from 3 patients (2.7٪). Among the patients for whom morphologically valuable specimens were obtained (n=101), the diagnosis of malignant tumor was confirmed in 76 cases (75.2%). In all remaining cases (n=25, 24.8%), benign lesions or inflammatory/post-inflammatory changes were diagnosed. Complications of various severity degrees occurred in 17 cases (15.5%). No deaths were reported (0%). The findings revealed no statistically significant differences in the frequency of cases with a verified diagnosis based on the diameter of the biopsy needle (p=0.124). Furthermore, the analysis revealed no statistically significant effect of the diameter of the biopsy needle (16G or 18G) on the overall complication rate (18.2 and 9%, respectively; p=0.266) and the frequency of pleural drainage for postoperative pneumothorax (10.4 and 6%, respectively; p=0.72). CONCLUSIONS: The CT-guided robot-assisted transthoracic lung biopsy is a safe and effective technique for the morphological verification of malignant tumors.


  • Open Access

    The Difficulties of Diagnosis Giant Angiomyolipoma of the Liver: Clinical Case and Literature Review

    by A. V. Arablinskii, O. P. Myasnyankina, A. A. Sedova, M. P. Onischenko

    Purpose: To report a clinical case demonstrating difficulties of diagnosis and successful surgical treatment of myomatous type of angiomyolipoma of the liver without simultaneous damage to the kidneys.Material and methods: A female patient, 49 years old, was admitted to the hospital in August 2023, had no specific complaints, an abdominal ultrasound revealed extraperitoneal extraorgan mass in the epigastrium and mesogastrium and masses in the right lobe of liver, most likely hemangioma. The contrast-enhanced MSCT was performed on admission. Patient was rehospitalized for a surgery in September. During the operation the tumor was removed and sent for histological examination, a further immunohistochemical study was also carried out.Results: According to the results of MSCT in S3, S4, S5 of the liver oval-shaped mass (198×104×177 mm) with heterogeneous density and solid, cystic and fat features was found. Three hypovascular hypodense inclusions sizes up to 11 mm was also identified in S7/8. There was no pathologic formation in the kidneys. The liver tumor was surgically removed, the resected material was directed to a scheduled histological examination. To confirm the diagnosis an IHC analysis was also done and it revealed the expression of melanocytic (HBM-45) and smooth muscle (SMA) markers.Discussion: In this case we encountered very sparsely described in the world literature localization of angiomyolipoma — isolated hepatic one (without kidney damage). Like other authors we encountered the similarity of muomatous tumor type to the HCC and adenoma of the liver due to the characteristic features of visualization: hypervascularity, early contrast enhancement into an arterial phase and reduced density relative to the preserved parenchyma of the liver into a delayed phase of contrast.Conclusion: This case demonstrates the difficulty of diagnosing the myomatous type of AML simulating the HCC. As one of the most informative methods of diagnosis, we single out MSCT, which allowed us to think about the possibility of a benign nature of the tumor. In our case the main features excluding HCC were the absence of rapid “washout” of contrast drug, the presence of lipomatous areas and no accumulation of contrast agent by the capsule.

  • Open Access

    Spontaneous drainage of the pseudocyst of the tail of the pancreas with the formation of a junction between the cyst and the stomach

    by E. V. Potekhina, O. Yu. Vasilenko, Z. N. Golikova, M. P. Onishchenko, A. S. Noskova, E. M. Bachurina, O. S. Morozova

    The aim of the study was to evaluate the informative value of various diagnostic methods for spontaneous drainage of the pancreatic pseudocyst into the stomach.Materials and methods: based on the clinical observation of a patient who received complaints of pain in the epigastrium, an episode of melena, after suffering acute pancreatitis several years ago with the development of pancreatic necrosis with an outcome in the cyst of the tail of the pancreas, drainage of the omentum bag. The patient underwent a comprehensive laboratory and instrumental examination.Results: ultrasound, endoscopic examination, MSCT suspected a malignant process in the stomach with ulceration and germination into the pancreas. After performing endoscopic ultrasonography, it was possible to differentiate the layers of the formation and make the correct diagnosis, which was confirmed by subsequent MSCT with oral contrast.Conclusions: a spontaneously opened pancreatic pseudocyst in the lumen of the stomach is a rare and difficult to diagnose disease. An integrated approach, including endoscopic, ultrasound, X-ray, and laboratory methods of investigation when compared with the clinical picture, allows us to verify the formation of the pancreas.

  • Open Access

    DEBUT OF COGNITIVE IMPARTMENT IN A PATIENT DUE TO THE PROGRESSIVE GROWTH OF MULTIPLE BRAIN MENINGIOMAS

    by O.V. Gaisenok, United Hospital with Outpatient Department, I.N. Tobolov, M.P. Onishchenko