Liang Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Liang Zhu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Fangbin Wang
School of Food and Biological Engineering, Hefei University of Technology, Hefei, China
1 shared publication- Fangbin Wang
Hefei University of Technology, Hefei, 230009, China
1 shared publication Jiangwei Li
School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin 150001, China
1 shared publication- Jiao Yang
School of Science, Harbin Institute of Technology, Shenzhen 518055, China
1 shared publication Jing Qi
Department of Chemistry, National University of Singapore, Singapore 117543, Singapore
1 shared publication- Jing Qi
Department of Chemistry, National University of Singapore, Singapore, Singapore
1 shared publication
Latest Publications
- 8 June 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (24) , 9953-9960
Ultrastable Luminol–OH–-(Ni-WOx-CNT) ECL System with High Strength and Its Applications in Sensing
In traditional luminol electrochemiluminescence (ECL) systems, hydrogen peroxide (H2O2) and dissolved oxygen (DO) are the commonly used coreactants to generate reactive oxygen species (ROS) for ECL emission. However, the self-decomposition of hydrogen peroxide and the limited solubility and content of oxygen in solution undoubtedly restrict the luminescence efficiency and stability of the luminol ECL system. Inspired by the ROS-mediated ECL mechanism, we pioneered hydroxide ion as an advanced luminol ECL coreactant using nickel-doped and carbon nanotube-modified tungsten oxide (Ni-WOx-CNT) as the coreactant accelerator. Owing to the excellent catalytic activity of Ni-WOx-CNT, amounts of ROS were generated from OH- at a low excitation voltage, which subsequently reacted with luminol anion radicals and triggered intense ECL signals. Experiments confirmed an impressive ECL behavior in terms of high luminescent intensity (85,563 a.u.) and super stability over 1300 consecutive tests; both are superior to those recently reported luminol-H2O2 and luminol-DO systems with smaller ECL intensities and consecutive tests less than 25 times. To validate the feasibility and versatility of the developed system in sensor, traditional three-electrodes system and closed bipolar electrodes system with various sensing strategies of direct oxidation, "gate-effect" of molecularly imprinted polymer, immune reaction, and enzyme-catalyzed reaction were proposed to monitor uric acid (UA), C-reactive protein (CRP), immunoglobulin G (IgG), and glucose (Glu). The superior sensing performances confirmed the great application potential of the developed ROS-mediated ECL system.
- 8 June 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (24) , 9953-9960
Ultrastable Luminol–OH–-(Ni-WOx-CNT) ECL System with High Strength and Its Applications in Sensing
In traditional luminol electrochemiluminescence (ECL) systems, hydrogen peroxide (H2O2) and dissolved oxygen (DO) are the commonly used coreactants to generate reactive oxygen species (ROS) for ECL emission. However, the self-decomposition of hydrogen peroxide and the limited solubility and content of oxygen in solution undoubtedly restrict the luminescence efficiency and stability of the luminol ECL system. Inspired by the ROS-mediated ECL mechanism, we pioneered hydroxide ion as an advanced luminol ECL coreactant using nickel-doped and carbon nanotube-modified tungsten oxide (Ni-WOx-CNT) as the coreactant accelerator. Owing to the excellent catalytic activity of Ni-WOx-CNT, amounts of ROS were generated from OH- at a low excitation voltage, which subsequently reacted with luminol anion radicals and triggered intense ECL signals. Experiments confirmed an impressive ECL behavior in terms of high luminescent intensity (85,563 a.u.) and super stability over 1300 consecutive tests; both are superior to those recently reported luminol-H2O2 and luminol-DO systems with smaller ECL intensities and consecutive tests less than 25 times. To validate the feasibility and versatility of the developed system in sensor, traditional three-electrodes system and closed bipolar electrodes system with various sensing strategies of direct oxidation, "gate-effect" of molecularly imprinted polymer, immune reaction, and enzyme-catalyzed reaction were proposed to monitor uric acid (UA), C-reactive protein (CRP), immunoglobulin G (IgG), and glucose (Glu). The superior sensing performances confirmed the great application potential of the developed ROS-mediated ECL system.
- Open Access
- 17 April 2024
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 416 (13) , 3139-3148
Paper-based fluorescence sensor array with functionalized carbon quantum dots for bacterial discrimination using a machine learning algorithm
The rapid discrimination of bacteria is currently an emerging trend in the fields of food safety, medical detection, and environmental observation. Traditional methods often require lengthy culturing processes, specialized analytical equipment, and bacterial recognition receptors. In response to this need, we have developed a paper-based fluorescence sensor array platform for identifying different bacteria. The sensor array is based on three unique carbon quantum dots (CQDs) as sensing units, each modified with a different antibiotic (polymyxin B, ampicillin, and gentamicin). These antibiotic-modified CQDs can aggregate on the bacterial surface, triggering aggregation-induced fluorescence quenching. The sensor array exhibits varying fluorescent responses to different bacterial species. To achieve low-cost and portable detection, CQDs were formulated into fluorescent ink and used with an inkjet printer to manufacture paper-based sensor arrays. A smartphone was used to collect the responses generated by the bacteria and platform. Diverse machine learning algorithms were utilized to discriminate bacterial types. Our findings showcase the platform's remarkable capability to differentiate among five bacterial strains, within a detection range spanning from 1.0 × 103 CFU/mL to 1.0 × 107 CFU/mL. Its practicality is further validated through the accurate identification of blind bacterial samples. With its cost-effectiveness, ease of fabrication, and high degree of integration, this platform holds significant promise for on-site detection of diverse bacteria. Graphical abstract
- 17 April 2024
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 416 (13) , 3139-3148
Open AccessPaper-based fluorescence sensor array with functionalized carbon quantum dots for bacterial discrimination using a machine learning algorithm
The rapid discrimination of bacteria is currently an emerging trend in the fields of food safety, medical detection, and environmental observation. Traditional methods often require lengthy culturing processes, specialized analytical equipment, and bacterial recognition receptors. In response to this need, we have developed a paper-based fluorescence sensor array platform for identifying different bacteria. The sensor array is based on three unique carbon quantum dots (CQDs) as sensing units, each modified with a different antibiotic (polymyxin B, ampicillin, and gentamicin). These antibiotic-modified CQDs can aggregate on the bacterial surface, triggering aggregation-induced fluorescence quenching. The sensor array exhibits varying fluorescent responses to different bacterial species. To achieve low-cost and portable detection, CQDs were formulated into fluorescent ink and used with an inkjet printer to manufacture paper-based sensor arrays. A smartphone was used to collect the responses generated by the bacteria and platform. Diverse machine learning algorithms were utilized to discriminate bacterial types. Our findings showcase the platform's remarkable capability to differentiate among five bacterial strains, within a detection range spanning from 1.0 × 103 CFU/mL to 1.0 × 107 CFU/mL. Its practicality is further validated through the accurate identification of blind bacterial samples. With its cost-effectiveness, ease of fabrication, and high degree of integration, this platform holds significant promise for on-site detection of diverse bacteria. Graphical abstract