ASAndrew A. Stanley

Andrew A. Stanley

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andrew A. Stanley has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    High-speed fluidic processing circuits for dynamic control of haptic and robotic systems

    by Andrew A. Stanley, Erik S. Roby, Sean J. Keller

    Fluidic logic circuits simplify system design for soft robotics by eliminating bulky components while enabling operation in a range of hostile environments that are incompatible with electronics but at the expense of limited computational capabilities and response times on the order of seconds. This paper presents a four-terminal fluidic transistor optimized for fast switching times, reduced component count, low unit cost, and high reproducibility to achieve complex fluidic control circuits while maintaining flow rates of liters per minute. A ring oscillator using three fluidic transistors achieves oscillation frequencies up to a kilohertz with full signal propagation, tolerating billions of cycles without failure. Fundamental processor circuits like a full adder and a 3-bit analog-to-digital converter require just seven transistors each. A decode circuit drives a high-resolution soft haptic display with refresh times below the human perception threshold for latency, and an electronics-free control circuit performs closed-loop position control of a pneumatic actuator with disturbance rejection, demonstrating the value across domains.


  • Integrated Pneumatic Sensing and Actuation for Soft Haptic Devices

    by Hojung Choi, Mark R. Cutkosky, Andrew A. Stanley

    We present an integrated pneumatic sensor and actuator for soft haptic devices that can estimate contact force, location, and shape using a multi-headed neural network. The sensor uses channels cast into a multi-layer silicone bubble that change flow resistance as the bubble deforms, allowing measurements of strain and external contact at the surface. Changes in flow resistance are measured using pressure transducers in a pneumatic circuit. Arranging the channels in a two-layer array allows localization of the strain with an accuracy of over 80% for contact locations in a 3×3 grid and force measurements from 0.9–4.5 N with an RMS error of $\approx$ 0.39 N. This technology can enable closed-loop control for future soft pneumatic devices.