Aliya Zilgarayeva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Aliya Zilgarayeva has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Nurzhigit Smailov
Department of Electronics, Telecommunications and Space Technologies, Satbayev University, Almaty 050013, Kazakhstan
3 shared publications - Bakhytzhan Kulambayev
Turan University
2 shared publications - Dinara Nurpeissova
Satbayev University
2 shared publications - Sergii V. Pavlov
Department of Biomedical Engineering and Optic-Electronic Systems, Vinnytsia National Technical University, 21021 Vinnytsia, Ukraine
2 shared publications - Akezhan Sabibolda
Department of Electronics, Telecommunications and Space Technologies, Satbayev University, Almaty 050013, Kazakhstan
1 shared publication - Balzhan Turusbekova
Department of Radio Engineering Satbayev University Electronics and Space Technologies Almaty Kazakhstan
1 shared publication
Latest Publications
- Open Access
- 1 May 2026
- Published by WNGB Scientific Publishing House Sp. z o.o. in Advances in Science and Technology Research Journal
- Vol. 20 (5) , 281-292
Development and experimental validation of a non-invasive near-infrared spectroscopic sensor system for blood glucose monitoring
Non-invasive blood glucose monitoring remains a major challenge in biomedical sensing due to strong light scattering in biological tissues, physiological variability, and limited signal stability of existing optical methods. Near-infrared (NIR) spectroscopy has attracted significant...
- 1 May 2026
- Published by WNGB Scientific Publishing House Sp. z o.o. in Advances in Science and Technology Research Journal
- Vol. 20 (5) , 281-292
Open AccessDevelopment and experimental validation of a non-invasive near-infrared spectroscopic sensor system for blood glucose monitoring
Non-invasive blood glucose monitoring remains a major challenge in biomedical sensing due to strong light scattering in biological tissues, physiological variability, and limited signal stability of existing optical methods. Near-infrared (NIR) spectroscopy has attracted significant...
- Open Access
- 20 December 2025
- Published by Politechnika Lubelska in Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
- Vol. 15 (4) , 65-70
Optimization of non-invasive glucose monitoring accuracy using an optical sensor
The development of non-invasive blood glucose monitoring technologies is progressing steadily, largely due to advancements in optical sensor systems. These systems assess physiological data by analyzing how light interacts with biological tissues. A common technique, near-infrared spectroscopy, typically utilizes wavelengths such as 500 nm, 970 nm, 1400 nm, and 1900 nm, selected for their enhanced responsiveness to glucose levels at varying tissue depths. In experimental settings, this method has demonstrated the ability to generate electrical signals that correlate with glucose concentrations, supporting its potential for accurate glucose tracking. The technique adheres to both detection and precision standards, particularly at higher glucose concentrations, making it a strong candidate for next-generation monitoring solutions. The study also outlines future objectives, including improving sensor accuracy, reducing device size, and enabling seamless integration with both clinical and home-based healthcare systems. Moreover, efforts to minimize interference and signal distortions are explored as part of the broader aim to refine system reliability.
- 20 December 2025
- Published by Politechnika Lubelska in Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
- Vol. 15 (4) , 65-70
Open AccessOptimization of non-invasive glucose monitoring accuracy using an optical sensor
The development of non-invasive blood glucose monitoring technologies is progressing steadily, largely due to advancements in optical sensor systems. These systems assess physiological data by analyzing how light interacts with biological tissues. A common technique, near-infrared spectroscopy, typically utilizes wavelengths such as 500 nm, 970 nm, 1400 nm, and 1900 nm, selected for their enhanced responsiveness to glucose levels at varying tissue depths. In experimental settings, this method has demonstrated the ability to generate electrical signals that correlate with glucose concentrations, supporting its potential for accurate glucose tracking. The technique adheres to both detection and precision standards, particularly at higher glucose concentrations, making it a strong candidate for next-generation monitoring solutions. The study also outlines future objectives, including improving sensor accuracy, reducing device size, and enabling seamless integration with both clinical and home-based healthcare systems. Moreover, efforts to minimize interference and signal distortions are explored as part of the broader aim to refine system reliability.
- Open Access
- 1 June 2024
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 34 (3) , 1489-1498
Optical sensor to improve the accuracy of non-invasive blood sugar monitoring
Optical sensors offer a painless method of monitoring blood glucose levels using various light technologies to analyze blood characteristics without penetrating the skin. The literature review part reflects the progress in optical sensor technology evaluates its potential in blood glucose monitoring by overcoming the limitations of conventional methods and recognizes the challenges and future prospects in this rapidly developing area of research. The results of empirical studies are then presented. The methodology is presented as a non-invasive method of blood glucose monitoring based on near-infrared spectroscopy. To precisely evaluate blood glucose concentrations, spectroscopy techniques involving absorption and reflection are employed at wavelengths 450, 900, 1350, and 1800 nm. After absorption and reflection of glucose molecules, light is generated. An experimental study of different samples revealed a linear relationship between the final output voltage and sugar concentration. The results demonstrate a correlation between blood glucose level and signal intensity after transmission.
- 1 June 2024
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 34 (3) , 1489-1498
Open AccessOptical sensor to improve the accuracy of non-invasive blood sugar monitoring
Optical sensors offer a painless method of monitoring blood glucose levels using various light technologies to analyze blood characteristics without penetrating the skin. The literature review part reflects the progress in optical sensor technology evaluates its potential in blood glucose monitoring by overcoming the limitations of conventional methods and recognizes the challenges and future prospects in this rapidly developing area of research. The results of empirical studies are then presented. The methodology is presented as a non-invasive method of blood glucose monitoring based on near-infrared spectroscopy. To precisely evaluate blood glucose concentrations, spectroscopy techniques involving absorption and reflection are employed at wavelengths 450, 900, 1350, and 1800 nm. After absorption and reflection of glucose molecules, light is generated. An experimental study of different samples revealed a linear relationship between the final output voltage and sugar concentration. The results demonstrate a correlation between blood glucose level and signal intensity after transmission.