KWKunlun Wang

Kunlun Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kunlun Wang has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    UniFORM: Towards Universal ImmunoFluorescence Normalization for Multiplex Tissue Imaging

    by Kunlun Wang, Kaoutar Ait-Ahmad, Samuel D Kupp, Zachary Sims, Eric Cramer, Zeynep Sayar, Jessica Yu, Melissa H. Wong, Gordon B. Mills, S. Ece Eksi, et al.

    Multiplexed tissue imaging (MTI) technologies enable high-dimensional spatial analysis of tumor microenvironments but face challenges with technical variability in staining intensities. Existing normalization methods, including Z-score, ComBat, and MxNorm, often fail to account for the heterogeneous, right-skewed expression patterns of MTI data, compromising signal alignment and downstream analyses. We present UniFORM, a non-parametric, Python-based pipeline that uses an automated rigid landmark functional data registration approach for normalizing both feature- and pixel-level MTI data. Designed specifically for the distributional characteristics of MTI datasets, UniFORM operates without prior distributional assumptions and performs robustly regardless of distribution modality, including both unimodal and bimodal patterns. It removes technical variation by aligning the biologically invariant component of the signal, typically the negative (non-expressing) population, while preserving biologically meaningful variation in the positive population, thereby maintaining tissue-specific expression patterns essential for downstream analysis. Benchmarking across three distinct MTI platform datasets demonstrates that UniFORM outperforms existing methods in mitigating batch effects while maintaining biological signal fidelity. This is evidenced by improved marker distribution alignment and positive population preservation, enhanced kBET and Silhouette scores, and improved downstream analyses such as UMAP visualizations and Leiden clustering. UniFORM also introduces a novel guided fine-tuning option for complex and heterogeneous datasets. Although optimized for fluorescence-based platforms, UniFORM provides a scalable and robust solution for MTI data normalization, enabling accurate and biologically meaningful interpretations.


  • Open Access

    COEXIST: Coordinated single-cell integration of serial multiplexed tissue images

    by Robert T. Heussner, Cameron F. Watson, Christopher Z. Eddy, Kunlun Wang, Eric M. Cramer, Allison L. Creason, Gordon B. Mills, Young Hwan Chang

    Multiplexed tissue imaging (MTI) and other spatial profiling technologies commonly utilize serial tissue sectioning to comprehensively profile samples by imaging each section with unique biomarker panels or assays. The dependence on serial sections is attributed to technological limitations of MTI panel size or incompatible multi-assay protocols. Although image registration can align serially sectioned MTIs, integration at the single-cell level poses a challenge due to inherent biological heterogeneity. Existing computational methods overlook both cell population heterogeneity across modalities and spatial information, which are critical for effectively completing this task. To address this problem, we first use Monte-Carlo simulations to estimate the overlap between serial 5μm-thick sections. We then introduce COEXIST, a novel algorithm that synergistically combines shared molecular profiles with spatial information to seamlessly integrate serial sections at the single-cell level. We demonstrate COEXIST necessity and performance across several applications. These include combining MTI panels for improved spatial single-cell profiling, rectification of miscalled cell phenotypes using a single MTI panel, and the comparison of MTI platforms at single-cell resolution. COEXIST not only elevates MTI platform validation but also overcomes the constraints of MTI’s panel size and the limitation of full nuclei on a single slide, capturing more intact nuclei in consecutive sections and thus enabling deeper profiling of cell lineages and functional states.


  • Open Access

    BeatProfiler: Multimodal In Vitro Analysis of Cardiac Function Enables Machine Learning Classification of Diseases and Drugs

    by Youngbin Kim, Kunlun Wang, Roberta I. Lock, Trevor R. Nash, Sharon Fleischer, Bryan Z. Wang, Barry M. Fine, Gordana Vunjak-Novakovic

    Goal: Contractile response and calcium handling are central to understanding cardiac function and physiology, yet existing methods of analysis to quantify these metrics are often time-consuming, prone to mistakes, or require specialized equipment/license. We developed BeatProfiler, a suite of cardiac analysis tools designed to quantify contractile function, calcium handling, and force generation for multiple in vitro cardiac models and apply downstream machine learning methods for deep phenotyping and classification. Methods: We first validate BeatProfiler's accuracy, robustness, and speed by benchmarking against existing tools with a fixed dataset. We further confirm its ability to robustly characterize disease and dose-dependent drug response. We then demonstrate that the data acquired by our automatic acquisition pipeline can be further harnessed for machine learning (ML) analysis to phenotype a disease model of restrictive cardiomyopathy and profile cardioactive drug functional response. To accurately classify between these biological signals, we apply feature-based ML and deep learning models (temporal convolutional-bidirectional long short-term memory model or TCN-BiLSTM). Results: Benchmarking against existing tools revealed that BeatProfiler detected and analyzed contraction and calcium signals better than existing tools through improved sensitivity in low signal data, reduction in false positives, and analysis speed increase by 7 to 50-fold. Of signals accurately detected by published methods (PMs), BeatProfiler's extracted features showed high correlations to PMs, confirming that it is reliable and consistent with PMs. The features extracted by BeatProfiler classified restrictive cardiomyopathy cardiomyocytes from isogenic healthy controls with 98% accuracy and identified relax90 as a top distinguishing feature in congruence with previous findings. We also show that our TCN-BiLSTM model was able to classify drug-free control and 4 cardiac drugs with different mechanisms of action at 96% accuracy. We further apply Grad-CAM on our convolution-based models to identify signature regions of perturbations by these drugs in calcium signals. Conclusions: We anticipate that the capabilities of BeatProfiler will help advance in vitro studies in cardiac biology through rapid phenotyping, revealing mechanisms underlying cardiac health and disease, and enabling objective classification of cardiac disease and responses to drugs.