Marko Gjorgjevski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marko Gjorgjevski has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Christopher Nimsky
Department of Neurosurgery, Philipps-University Marburg, Marburg, Germany
4 shared publications - Alexander Grote
Department of Neurosurgery, University Hospital Marburg, Philipps University Marburg, Baldingerstrasse, 35043 Marburg, Germany
3 shared publications - Barbara Carl
Department of Neurosurgery, University Hospital Marburg, Philipps University Marburg, Baldingerstrasse, 35043 Marburg, Germany
3 shared publications - Miriam Helen Anna Bauer
Department of Neurosurgery, University Hospital Marburg, Philipps University Marburg, Baldingerstrasse, 35043 Marburg, Germany
3 shared publications - Katja Menzler
Epilepsy Center Hessen, Department of Neurology, Philipps-University Marburg, Marburg, Germany
2 shared publications - Susanne Knake
Epilepsy Center Hesse, Department for Neurology, University Hospital Marburg, Philipps University Marburg, Baldingerstrasse, 35043 Marburg, Germany
2 shared publications
Latest Publications
- Open Access
Intraoperative Computed Tomography, Ultrasound, and Augmented Reality in Mesial Temporal Lobe Epilepsy Surgery—A Retrospective Cohort Study
Mesial temporal lobe epilepsy (mTLE) surgery, particularly selective amygdalohippocampectomy (sAHE), is a recognized treatment for pharmacoresistant temporal lobe epilepsy (TLE). Accurate intraoperative orientation is crucial for complete resection while maintaining functional integrity. This study evaluated the usability and effectiveness of multimodal neuronavigation and microscope-based augmented reality (AR) with intraoperative computed tomography (iCT) and navigated intraoperative ultrasound (iUS) in 28 patients undergoing resective surgery. Automatic iCT-based registration provided high initial navigation accuracy. Navigated iUS was utilized to verify navigational accuracy and assess the extent of resection during the procedure. AR support was successfully implemented in all cases, enhancing surgical orientation, surgeon comfort, and patient safety, while also aiding training and education. At one-year follow-up, 60.7% of patients achieved complete seizure freedom (ILAE Class 1), rising to 67.9% at the latest follow-up (median 4.6 years). Surgical complications were present in three cases (10.7%), but none resulted in permanent deficits. The integration of microscope-based AR with iCT and navigated iUS provides a precise and safe approach to resection in TLE surgery, additionally serving as valuable tool for neurosurgical training and education.
Open AccessIntraoperative Computed Tomography, Ultrasound, and Augmented Reality in Mesial Temporal Lobe Epilepsy Surgery—A Retrospective Cohort Study
Mesial temporal lobe epilepsy (mTLE) surgery, particularly selective amygdalohippocampectomy (sAHE), is a recognized treatment for pharmacoresistant temporal lobe epilepsy (TLE). Accurate intraoperative orientation is crucial for complete resection while maintaining functional integrity. This study evaluated the usability and effectiveness of multimodal neuronavigation and microscope-based augmented reality (AR) with intraoperative computed tomography (iCT) and navigated intraoperative ultrasound (iUS) in 28 patients undergoing resective surgery. Automatic iCT-based registration provided high initial navigation accuracy. Navigated iUS was utilized to verify navigational accuracy and assess the extent of resection during the procedure. AR support was successfully implemented in all cases, enhancing surgical orientation, surgeon comfort, and patient safety, while also aiding training and education. At one-year follow-up, 60.7% of patients achieved complete seizure freedom (ILAE Class 1), rising to 67.9% at the latest follow-up (median 4.6 years). Surgical complications were present in three cases (10.7%), but none resulted in permanent deficits. The integration of microscope-based AR with iCT and navigated iUS provides a precise and safe approach to resection in TLE surgery, additionally serving as valuable tool for neurosurgical training and education.
- Open Access
- 12 February 2025
- Published by MDPI AG in Brain Sciences
- Vol. 15 (2) , 184
Frameless Stereotaxy in Stereoelectroencephalography Using Intraoperative Computed Tomography
Background: Pharmacoresistant epilepsy affects approximately one-third of all epilepsy patients, and resective surgery may offer favorable outcomes for carefully selected patients with focal epilepsy. The accurate identification of the epileptogenic zone (EZ) is essential for successful surgery, particularly in cases where non-invasive diagnostics are inconclusive. Invasive diagnostics with stereoelectroencephalography (SEEG) offer a reliable approach to localizing the EZ, especially in MRI-negative cases. Methods: This retrospective study analyzed the data of 22 patients with pharmacoresistant epilepsy who underwent frameless stereotactic SEEG electrode implantation with automated CT-based registration between September 2016 and November 2024. For measuring accuracy, Euclidean distance, radial deviation, angular deviation, and depth deviation were calculated for each electrode. Results: A total of 153 depth electrodes were implanted, targeting various cortical regions. The median Euclidean distance at the entry point was 1.54 mm (IQR 1.31), with a radial deviation of 1.33 mm (IQR 1.32). At the target level, the median Euclidean distance was 2.61 mm (IQR 1.53), with a radial deviation of 1.67 mm (IQR 1.54) and depth deviation of 0.95 mm (IQR 2.43). Accuracy was not significantly affected by electrode order, anatomical location, skull thickness, or intracranial length. Conclusions: These findings demonstrate that frameless stereotactic SEEG electrode implantation is safe and feasible for identifying the EZ. The integration of automatic intraoperative CT-based registration ensures precision. While maintaining workflow efficiency, it achieves accuracy comparable to frame-based methods. Further studies with larger cohorts are warranted to validate these results and assess their impact on surgical outcomes.
- 12 February 2025
- Published by MDPI AG in Brain Sciences
- Vol. 15 (2) , 184
Open AccessFrameless Stereotaxy in Stereoelectroencephalography Using Intraoperative Computed Tomography
Background: Pharmacoresistant epilepsy affects approximately one-third of all epilepsy patients, and resective surgery may offer favorable outcomes for carefully selected patients with focal epilepsy. The accurate identification of the epileptogenic zone (EZ) is essential for successful surgery, particularly in cases where non-invasive diagnostics are inconclusive. Invasive diagnostics with stereoelectroencephalography (SEEG) offer a reliable approach to localizing the EZ, especially in MRI-negative cases. Methods: This retrospective study analyzed the data of 22 patients with pharmacoresistant epilepsy who underwent frameless stereotactic SEEG electrode implantation with automated CT-based registration between September 2016 and November 2024. For measuring accuracy, Euclidean distance, radial deviation, angular deviation, and depth deviation were calculated for each electrode. Results: A total of 153 depth electrodes were implanted, targeting various cortical regions. The median Euclidean distance at the entry point was 1.54 mm (IQR 1.31), with a radial deviation of 1.33 mm (IQR 1.32). At the target level, the median Euclidean distance was 2.61 mm (IQR 1.53), with a radial deviation of 1.67 mm (IQR 1.54) and depth deviation of 0.95 mm (IQR 2.43). Accuracy was not significantly affected by electrode order, anatomical location, skull thickness, or intracranial length. Conclusions: These findings demonstrate that frameless stereotactic SEEG electrode implantation is safe and feasible for identifying the EZ. The integration of automatic intraoperative CT-based registration ensures precision. While maintaining workflow efficiency, it achieves accuracy comparable to frame-based methods. Further studies with larger cohorts are warranted to validate these results and assess their impact on surgical outcomes.
- Open Access
Enabling Navigation and Augmented Reality in the Sitting Position in Posterior Fossa Surgery Using Intraoperative Ultrasound
Despite its broad use in cranial and spinal surgery, navigation support and microscope-based augmented reality (AR) have not yet found their way into posterior fossa surgery in the sitting position. While this position offers surgical benefits, navigation accuracy and thereof the use of navigation itself seems limited. Intraoperative ultrasound (iUS) can be applied at any time during surgery, delivering real-time images that can be used for accuracy verification and navigation updates. Within this study, its applicability in the sitting position was assessed. Data from 15 patients with lesions within the posterior fossa who underwent magnetic resonance imaging (MRI)-based navigation-supported surgery in the sitting position were retrospectively analyzed using the standard reference array and new rigid image-based MRI-iUS co-registration. The navigation accuracy was evaluated based on the spatial overlap of the outlined lesions and the distance between the corresponding landmarks in both data sets, respectively. Image-based co-registration significantly improved (p < 0.001) the spatial overlap of the outlined lesion (0.42 ± 0.30 vs. 0.65 ± 0.23) and significantly reduced (p < 0.001) the distance between the corresponding landmarks (8.69 ± 6.23 mm vs. 3.19 ± 2.73 mm), allowing for the sufficient use of navigation and AR support. Navigated iUS can therefore serve as an easy-to-use tool to enable navigation support for posterior fossa surgery in the sitting position.
Open AccessEnabling Navigation and Augmented Reality in the Sitting Position in Posterior Fossa Surgery Using Intraoperative Ultrasound
Despite its broad use in cranial and spinal surgery, navigation support and microscope-based augmented reality (AR) have not yet found their way into posterior fossa surgery in the sitting position. While this position offers surgical benefits, navigation accuracy and thereof the use of navigation itself seems limited. Intraoperative ultrasound (iUS) can be applied at any time during surgery, delivering real-time images that can be used for accuracy verification and navigation updates. Within this study, its applicability in the sitting position was assessed. Data from 15 patients with lesions within the posterior fossa who underwent magnetic resonance imaging (MRI)-based navigation-supported surgery in the sitting position were retrospectively analyzed using the standard reference array and new rigid image-based MRI-iUS co-registration. The navigation accuracy was evaluated based on the spatial overlap of the outlined lesions and the distance between the corresponding landmarks in both data sets, respectively. Image-based co-registration significantly improved (p < 0.001) the spatial overlap of the outlined lesion (0.42 ± 0.30 vs. 0.65 ± 0.23) and significantly reduced (p < 0.001) the distance between the corresponding landmarks (8.69 ± 6.23 mm vs. 3.19 ± 2.73 mm), allowing for the sufficient use of navigation and AR support. Navigated iUS can therefore serve as an easy-to-use tool to enable navigation support for posterior fossa surgery in the sitting position.
- Open Access
- 1 September 2021
- Published by Elsevier in Brain Stimulation
- Vol. 14 (5) , 1109-1117
Imaging-based programming of subthalamic nucleus deep brain stimulation in Parkinson's disease
- 1 September 2021
- Published by Elsevier in Brain Stimulation
- Vol. 14 (5) , 1109-1117
Open AccessImaging-based programming of subthalamic nucleus deep brain stimulation in Parkinson's disease