KTKazuki Takaya

Kazuki Takaya

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kazuki Takaya has a total of 20 co-authors. Here are the top co-authors by number of shared publications:

  • Takuya Nagae

    Disaster Mitigation Research Center Nagoya University Nagoya Japan

    4 shared publications
  • Ryota Nishi

    Hyogo Earthquake Engineering Research Center, National Research Institute for Earth Science and Disaster Resilience (NIED), 1501-21 Nishikameya, Mitsuda, Shijimicho, Miki, Hyogo 673-0515, Japan

    3 shared publications
  • Tatsuya Asai

    Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505, Japan

    3 shared publications
  • Eiki Shigeta

    Graduate School of Environmental Studies, Nagoya University, Nagoya, Japan

    2 shared publications
  • Jialiang Jin

    State Key Laboratory of Disaster Reduction in Civil Engineering, Tongji University, Shanghai 200092, China

    2 shared publications
  • Jun Fujiwara

    Hyogo Earthquake Engineering Research Center, National Research Institute for Earth Science and Disaster Resilience (NIED), 1501-21 Nishikameya, Mitsuda, Shijimicho, Miki, Hyogo 673-0515, Japan

    2 shared publications

Latest Publications

  • Open Access

    Evaluation of Dynamic Characteristics of Facility Equipment and Damage to Support Members Based on Shaking Table Tests

    by Kazuki Takaya, Eiki Shigeta, Ryota Nishi, Jun Fujiwara, Kazuyuki Hidaka, Tatsuya Asai, Takuya Nagae

    Earthquake damage to building equipment lowers the functionality of the building and makes it difficult to continue its operation. Methods have been proposed to assess the performance of a building via a probabilistic view of the damage or repair costs for its structural and nonstructural components in the event of earthquakes, to assess the functionality of the building against earthquakes. In these methods, damage to the components is expressed by probability distributions (fragility curves) of the damage against the response of the building frame. However, actual damage to building equipment occurs as a result of the response of the equipment, which varies with the vibration characteristics of the building and the input seismic motions. Furthermore, the relation between the equipment response and damage based on dynamic models has not been quantified or sufficiently verified experimentally. In this study, shaking table tests were conducted on three types of air-conditioning units to investigate their dynamic characteristics and assess their damage. Additionally, a dynamic model that reflects the degree of fixation of a hanging-support air-conditioning unit to the support members was analyzed, and its predictions were compared against experimental data to quantitatively evaluate the relation between the initial damage to support members and the response acceleration of units, with the goal of producing fragility curves for building equipment.

  • Open Access

    Study on Advanced Seismic Performance Evaluation Methods for Building Equipment –Development of Fragility Function and Verification Using Full-Scale Experiment—

    by Ryota Nishi, Jun Fujiwara, Koichi Kajiwara, Kazuki Takaya, Eiki Shigeta, Tatsuya Asai

    To maintain the functionality of a building, it is crucial to understand the seismic behavior of its equipment and evaluate its seismic performance accurately. To enhance the precision of seismic performance evaluations, it is necessary to expand the fragility data for building equipment. This study explores a method for developing a fragility function based on the seismic design force specified in design guidelines. Using risk integrals, the study assesses the relationship between acceleration and damage probability, derived from earthquake damage surveys, to calculate the damage risk for building equipment designed and constructed according to Japanese design standards. The fragility function is then derived by analyzing the damage probability when the response acceleration exceeds the design acceleration. Additionally, through a comparative verification with shake table test results from a full-scale 10-story steel office building, the authors confirm the consistency between the derived fragility functions and experimental results. This approach is expected to improve the accuracy of predicting building equipment seismic behavior and provide more reliable seismic performance evaluations.


  • Numerical analysis of the seismic performance of a 10-story steel building with weak panel zones based on full-scale shake-table tests

    by Tianhao Yan, Jialiang Jin, Jionghui Li, Jun Fujiwara, Akiko Kishida, Ryota Nishi, Kazuki Takaya, Koichi Kajiwara, Tatsuya Asai, Taichiro Okazaki, et al.

  • Open Access

    Practical Repair Cost Assessment of Steel Office Buildings with Diverse Beam-to-Column Connection Types in Japan

    by Kazuki Takaya, Jialiang Jin, Takuya Nagae

    This study investigates the seismic performance of beam-to-column connections in Japanese steel office buildings and evaluates their impact on repair costs as part of practical seismic loss assessment. Repair cost analysis is conducted following FEMA P-58 guidelines, utilizing a probabilistic seismic performance approach. Additionally, this study incorporates the damage and loss of non-structural components, accounting for uncertainties arising from various factors. By applying story loss functions and the Capacity Spectrum Method within the assessment framework of this study, the applicability of these methods in Japanese design practices is validated. A numerical model of a typical steel building is established based on prior experimental data, and a series of numerical analyses are conducted to quantitatively assess variations in building response distribution and fragility resulting from different beam-to-column connection types. Analysis results indicate that, within the range up to maximum strength, differences in connection performance contribute more to variations in fragility than to building response. Component fragility is particularly influenced by connection type and dimensions that affect inter-story drift ratios. This approach highlights the potential cost differences driven by structural specifications and emphasizes the importance of connection-specific fragility in accurately estimating seismic repair costs in practical design. Furthermore, improvements in structural performance have limited effects in reducing non-structural damage, underscoring the necessity of directly enhancing non-structural component performance.


  • Open Access

    Comprehensive wood dwelling tests for Post‐and‐Beam and Shear‐Wall structures reflecting foundation boundaries

    by Kazuki Takaya, Kazuto Ota, Cem Yenidogan, Takehiro Takahashi, Shohei Yamada, Hisatoshi Kashiwa, Yosuke Kawamata, Kazuhiro Hayashi, Takuya Nagae

    This paper focuses on the ultimate state of three‐story wood dwellings with high aspect ratios, which are increasing in Japan's urban areas. Using shaking table test results from the 2019 full‐scale shaking table test, a comprehensive study is conducted on the accuracy of evaluating ultimate state through the story shear failure mode at the first story, the tension fracture mode at the wall base of the first story, and foundation sliding mode on the soil. Methods evaluating the dynamic response behaviors of the building systems are also investigated. In the test, the current Japanese seismic design guidelines were applied, and two Grade‐3 buildings were prepared. One adopted the Post‐and‐Beam structure (A‐building), and the other the Shear‐Wall structure (B‐building). A series of tests planned very different physical boundary conditions surrounding their reinforced concrete (RC) mat foundations. The sills, column bases and wall bases of the upper wood structures were anchored to the RC foundations by steel anchor bolts, according to the current Allowable Stress Design (ASD) requirements. In the first stage, A‐building equipped a Base‐Isolation system, while B‐building represented a generic foundation constructed on a 1.5 m‐height real soil ground by preparing a rigid soil box (Foundation‐Soil system). In the second stage of A‐building and B‐building, the foundation was firmly fixed (Fixed‐Foundation system), and shaking table motions were fully applied to the foundations. The entire test system was setup on the large shaking table facility at E‐Defense, and a series of tests were conducted using JMA‐Kobe motion and JR‐Takatori motion recorded in the 1995 Kobe earthquake as Maximum‐Considered‐Earthquake motions. Confirmed was the change in the structural mechanism due to the upper structural systems and the foundation boundaries. Regarding the upper wood structure performance in the Fixed‐Foundation system, a story shear failure mode was observed at the first story in A‐building, while a tension fracture mode at the base of the first story in B‐building. This difference of failure mode is difficult to determine with ASD. The maximum strength were more than four times higher than the ASD base shear force. Tension fracture capacity at the wall base was mainly enhanced by the presence of the steel anchor bolts. Regarding the foundation performance in Foundation‐Soil system of B‐building, a horizontal displacement up to 240 mm was observed between the foundation and soil when JMA‐Kobe 100% was applied. A response reduction effect was observed in the upper wood structure, similar to the Base‐Isolation system of A‐building. The initial friction and cyclic friction strength capacities between the foundation and soil were quantitatively evaluated considering the horizontal two‐directional sliding. The representative test results were converted to the corresponding SDOF systems based on the first mode response assessment. In the Fixed‐Foundation system, the dynamic response characteristics of the upper wood structures were properly represented using Ibarra‐Medina‐Krawinkler pinching model in the equivalent SDOF system.