  • Wind-induced vibration control study of tall building with internal-paddle-TLD system by different liquid sloshing damping models

    by Zhaorong Chen, Jiyang Fu, Jiurong Wu, Songlin Zhao, Peng Huang, Qiusheng Li, Xiaoxiong Liao, Yongfeng Liang, Nongchao Tan, Yuanhui Li, et al.

  • Open Access

    Optimization Design of TLD System with Internal Energy-Dissipation Components for Wind-Induced Vibration Control of Tall Building

    by Zhaorong Chen, Jiurong Wu, Peng Huang, Jiyang Fu, Songlin Zhao, Qiusheng Li, Xiaoxiong Liao, Zhuopeng Zheng, Jianjun Zhang, Jiurong Wu

    Wind-induced vibration control constitutes a critical issue for ensuring the structural safety and occupant comfort of super-tall buildings. Tuned Liquid Dampers (TLDs) are characterized by its simple configuration and favorable vibration reduction efficiency. Yet pure water yields relatively low inherent damping, thereby internal energy-dissipation components are required to strengthen energy dissipation capacity. Most existing optimization approaches neglect the coupled effects of internal components on the natural frequency and damping ratio of liquid sloshing, leading to compromised tuning precision and unsatisfactory control performance of TLD systems. Based on the classical optimization theory of Tuned Mass Dampers (TMDs) and the equivalent linearization method for TLDs, this paper derives formulations for optimization design of the linear equivalent damping ratio of TLDs equipped with internal vertical baffles and paddles. Taking the wind-induced acceleration response as the optimization objective, the optimal frequency ratio and optimal damping ratio are determined via numerical optimization procedure. A comprehensive design procedure is established, covering target vibration control efficiency, mass ratio, tank dimension determination, and energy-dissipation components parametric optimization design. The feasibility of the proposed method is adopted for the optimization design of the third-generation structural control benchmark model with internally baffled TLD system. Furthermore, optimization design for TLD system with internal paddles installed atop of a 338.1 m super-tall building is conducted. The optimization results derived from the proposed procedure are verified by the time history dynamic analysis on finite element model of the tall building under dynamic wind loading. The proposed method effectively enhances the wind-induced vibration control performance of TLDs with internal energy-dissipation components, providing theoretical and technical support for wind-induced comfort design of super-tall buildings.

  • Open Access

    Theoretical and experimental investigations on natural frequency and dynamic response of toroidal liquid column vibration absorber

    by Peng Huang, Jiurong Wu, Jiyang Fu, Songlin Zhao, Qiusheng Li, Ching Tai Ng

    Toroidal Liquid Column Vibration Absorber (TLCVA) features a toroidal and axially symmetric design, making it well-suited for multi-directional vibration control damper. However, the phenomena of both uneven liquid flow velocity within transition zone and Liquid Sloshing Mode Effect (LSME) in vertical liquid column of TLCVA make the accurate assessment of the natural frequency and frequency response of wave height of the liquid sloshing in TLCVA to be much complicated. Therefore the EFP model is proposed to investigate the uneven liquid flow within the transition zone by the Elliptical Flow Path (EFP) estimation method, and LSME model is established to further consider the liquid sloshing mode effect by introducing the spring-mass-damping system in the vertical columns of TLCVA. Assuming the investigated TLCVA to be equivalently modeled as the assembly of multiple LCVAs, the differentia motion equation of TLCVA with two basic configurations are derived by Hamilton principle. Thus the natural frequency and frequency response of wave height of the liquid sloshing in TLCVA can be numerically evaluated by adopting the proposed EFP, LSME and traditional models. Shake table tests on six TLCVAs with various structural parameters are also conducted by harmonic excitation and free vibration tests. Experiment results of dynamic characteristic of TLCVA were utilized to verify the effectiveness of the proposed models in this paper. Compared with the shake table test, the mean errors of estimated natural frequency of TLCVA are 7.62%, 3.42% and 2.18% for the traditional model, the proposed EFP and LSME model. As the size of transition zone increases, the discrepancy in the estimated frequency response of wave height in TLCVA between the traditional model and the experimental results generally increase. For the proposed EFP and LSME models, good agreements in the frequency response of wave height with the experimental results are found for the cases with different sizes of transition zone in the TLCVA. The proposed LSME model is shown to be the most accurate and reliable model to predict the natural frequency and frequency response of wave height of TLCVA system with all types of structural configurations in transition zones between vertical and horizontal liquid columns.

  • Open Access

    Monitoring of Wind Effects on a Super-Tall Building under a Typhoon

    by Haoran Pan, Jiurong Wu, Jiyang Fu

    Field measurements are critical to further understand the structural behavior of super-tall buildings under strong wind actions. This paper presents field measurements that reflect the wind characteristics and wind effects on Leatop Plaza under Typhoon Vicente. Wind field characteristics, including the turbulence intensity, gust factor, and power spectral density of wind speed in an urban area, were obtained on the basis of a statistical analysis of measured wind data. Subsequently, measured wind-induced accelerations were used to evaluate the dynamic characteristics of the building and the effects of wind on it. On the basis of the first several modes, the modal properties, i.e., the natural frequency and damping ratio, were identified via the fast Bayesian fast Fourier transform method and compared with those identified using the stochastic subspace method. The discrepancy between the identified results and finite element model predictions is presented and discussed. Finally, the variation in the modal parameters with respect to time and the vibration amplitude was analyzed while considering the associated posterior uncertainty.


  • Open Access

    Structural Responses of a Supertall Building Subjected to a Severe Typhoon at Landfall

    by Zhi Li, Jiyang Fu, Yuncheng He, Zhen Liu, Jiurong Wu, Rui Rao, Ching-Tai Ng

    Typhoon Mangkhut (1822) was one of the strongest tropical cyclones that ever impacted the south coast of China in past decades. During the passage of this typhoon, the structural health monitoring (SHM) system installed on a 303 m high building in this region worked effectively, and high-quality field measurements at nine height levels of the building were collected successfully, which provides a valuable opportunity to explore the dynamic properties of the building and the associated wind effects. In this study, the typhoon wind characteristics are presented first based on in-situ measurements at two sites. Acceleration responses of the building is then investigated, and the building’s serviceability is assessed against several comfort criteria. This study further focuses on the identification of modal parameters (i.e., natural frequency, damping ratio, and modal shape) via two methods: stochastic subspace identification (SSI) method and a method based on combined use of spectral analysis and random decrement technique (RDT). The good agreement between the two results demonstrates the effectiveness and the accuracy of the adopted methods. The obtained results are further compared with the stipulations in several technical codes as well as simulation results via finite element method to examine their performances in this real case. The amplitude dependence of natural frequencies and damping ratios of the studied building are also stressed.