Tomoyuki Hida
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tomoyuki Hida has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Kousei Ishigami
Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
2 shared publications - Akihiro Koga
Canon Medical Systems Corporation, Tochigi, Japan
1 shared publication - Daan Willem Loth
Department of Epidemiology, Erasmus MC, Rotterdam, The Netherlands
1 shared publication - Daniel Bos
Department of Epidemiology, Erasmus MC, Rotterdam, The Netherlands
1 shared publication - David Chistopher Christiani
39Pulmonary and Critical Care Division, Department of Medicine, Massachusetts General Hospital, Boston, Massachusetts
1 shared publication - Gary Matt Hunninghake
Department of Medicine, Brigham and Women’s Hospital, Boston, Massachusetts, USA
1 shared publication
Latest Publications
- Open Access
- 11 December 2025
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 44 (4) , 660-672
Automated interstitial lung abnormalities detection at CT: external validation and potential recognition of traction bronchiectasis/bronchiolectasis
Purpose: An artificial intelligence (AI) system for detecting interstitial lung abnormalities (ILA) was previously developed but requires external validation. This study aimed to examine the robustness across different populations and investigate associations between the system outputs and traction bronchiectasis/bronchiolectasis severity patterns. Materials and methods: CT scans from population-based samples of the Rotterdam Study (2018–2019) and the Age Gene/Environment Susceptibility Reykjavik (AGES-Reykjavik) Study (baseline CT: 2002–2006, follow-up CT: 2007–2011) were used in this secondary analysis of the two cohorts. The AI system calculated ILA probability score (AI score) in the range from 0 to 1. Three experienced readers evaluated independently all CT scans for ILA, and two chest radiologists assessed traction bronchiectasis/bronchiolectasis using the 4-scale traction bronchiectasis/bronchiolectasis index (TBI) for severity by consensus. Receiver operating characteristic (ROC) analysis and Kruskal–Wallis test were used for statistical analysis. Results: The system analyzed 932 CT scans of the Rotterdam Study (mean participant age, 79.6 years ± 4.3 (SD), 482 women) and 5242 CT scans of the AGES-Reykjavik Study (mean participant age, 76.4 years ± 5.6, 3032 women), and achieved area under the ROC curve of 0.841 (95% CI 0.804, 0.879) and 0.823 (95% CI 0.798, 0.847), respectively. AI scores correlated with readers’ certainty, decreasing from unanimous ILA cases to No-ILA cases. Higher baseline AI scores correlated with greater severity of traction bronchiectasis/bronchiolectasis (TBI-3: 0.931 [IQR, 0.911–0.932], TBI-2: 0.738 [IQR, 0.406–0.880], TBI-1: 0.537 [IQR, 0.317–0.761], TBI-0: 0.250 [IQR, 0.136–0.455]). Conclusion: The system demonstrated robust ILA detection performance across different populations, with AI scores showing associations with traction bronchiectasis/bronchiolectasis severity.
- 11 December 2025
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 44 (4) , 660-672
Open AccessAutomated interstitial lung abnormalities detection at CT: external validation and potential recognition of traction bronchiectasis/bronchiolectasis
Purpose: An artificial intelligence (AI) system for detecting interstitial lung abnormalities (ILA) was previously developed but requires external validation. This study aimed to examine the robustness across different populations and investigate associations between the system outputs and traction bronchiectasis/bronchiolectasis severity patterns. Materials and methods: CT scans from population-based samples of the Rotterdam Study (2018–2019) and the Age Gene/Environment Susceptibility Reykjavik (AGES-Reykjavik) Study (baseline CT: 2002–2006, follow-up CT: 2007–2011) were used in this secondary analysis of the two cohorts. The AI system calculated ILA probability score (AI score) in the range from 0 to 1. Three experienced readers evaluated independently all CT scans for ILA, and two chest radiologists assessed traction bronchiectasis/bronchiolectasis using the 4-scale traction bronchiectasis/bronchiolectasis index (TBI) for severity by consensus. Receiver operating characteristic (ROC) analysis and Kruskal–Wallis test were used for statistical analysis. Results: The system analyzed 932 CT scans of the Rotterdam Study (mean participant age, 79.6 years ± 4.3 (SD), 482 women) and 5242 CT scans of the AGES-Reykjavik Study (mean participant age, 76.4 years ± 5.6, 3032 women), and achieved area under the ROC curve of 0.841 (95% CI 0.804, 0.879) and 0.823 (95% CI 0.798, 0.847), respectively. AI scores correlated with readers’ certainty, decreasing from unanimous ILA cases to No-ILA cases. Higher baseline AI scores correlated with greater severity of traction bronchiectasis/bronchiolectasis (TBI-3: 0.931 [IQR, 0.911–0.932], TBI-2: 0.738 [IQR, 0.406–0.880], TBI-1: 0.537 [IQR, 0.317–0.761], TBI-0: 0.250 [IQR, 0.136–0.455]). Conclusion: The system demonstrated robust ILA detection performance across different populations, with AI scores showing associations with traction bronchiectasis/bronchiolectasis severity.
- 9 December 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 96 (1141) , 20220731
Impact of a new deep-learning-based reconstruction algorithm on image quality in ultra-high-resolution CT: clinical observational and phantom studies
Objectives: To demonstrate the effect of an improved deep learning-based reconstruction (DLR) algorithm on Ultra-High-Resolution Computed Tomography (U-HRCT) scanners. Methods: Clinical and phantom studies were conducted. Thirty patients who underwent contrast-enhanced CT examination during the follow-up period were enrolled. Images were reconstructed using improved DLR [termed, New DLR, i.e., Advanced Intelligent Clear-IQ Engine (AiCE) Body Sharp] and conventional DLR (Conv DLR, AiCE Body) algorithms. Two radiologists assessed the overall image quality using a 5-point scale (5 = excellent; 1 = unacceptable). The noise power spectra (NPSs) were calculated to assess the frequency characteristics of the image noise, and the square root of area under the curve (√AUC NPS) between 0.05 and 0.50 cycle/mm was calculated as an indicator of the image noise. Dunnett’s test was used for statistical analysis of the visual evaluation score, with statistical significance set at p < 0.05. Results: The overall image quality of New DLR was better than that of the Conv DLR (4.2 ± 0.4 and 3.3 ± 0.4, respectively; p < 0.0001). All New DLR images had an overall image quality score above the average or excellent. The √AUCNPS value of New DLR was lower than that of Conv DLR (13.8 and 14.2, respectively). The median values of reconstruction time required with New DLR and Conv DLR were 5.0 and 7.8 min, respectively. Conclusions: The new DLR algorithm improved the image quality within a practical reconstruction time. Advances in knowledge: The new DLR enables us to choose whether to improve image quality or reduce the dose.
- 9 December 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 96 (1141) , 20220731
Impact of a new deep-learning-based reconstruction algorithm on image quality in ultra-high-resolution CT: clinical observational and phantom studies
Objectives: To demonstrate the effect of an improved deep learning-based reconstruction (DLR) algorithm on Ultra-High-Resolution Computed Tomography (U-HRCT) scanners. Methods: Clinical and phantom studies were conducted. Thirty patients who underwent contrast-enhanced CT examination during the follow-up period were enrolled. Images were reconstructed using improved DLR [termed, New DLR, i.e., Advanced Intelligent Clear-IQ Engine (AiCE) Body Sharp] and conventional DLR (Conv DLR, AiCE Body) algorithms. Two radiologists assessed the overall image quality using a 5-point scale (5 = excellent; 1 = unacceptable). The noise power spectra (NPSs) were calculated to assess the frequency characteristics of the image noise, and the square root of area under the curve (√AUC NPS) between 0.05 and 0.50 cycle/mm was calculated as an indicator of the image noise. Dunnett’s test was used for statistical analysis of the visual evaluation score, with statistical significance set at p < 0.05. Results: The overall image quality of New DLR was better than that of the Conv DLR (4.2 ± 0.4 and 3.3 ± 0.4, respectively; p < 0.0001). All New DLR images had an overall image quality score above the average or excellent. The √AUCNPS value of New DLR was lower than that of Conv DLR (13.8 and 14.2, respectively). The median values of reconstruction time required with New DLR and Conv DLR were 5.0 and 7.8 min, respectively. Conclusions: The new DLR algorithm improved the image quality within a practical reconstruction time. Advances in knowledge: The new DLR enables us to choose whether to improve image quality or reduce the dose.