Joseph W. Betz has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Reliability of the Biomechanical Assessment of the Sagittal Thoracic Spine on Radiographs Used in Clinical Practice: A Systematic Literature Review

    by Joseph W. Betz, Douglas F. Lightstone, Jason W. Haas, Paul A. Oakley, Joseph R. Ferrantelli, Ibrahim M. Moustafa, Deed E. Harrison

    Background: Measurement reliability of the sagittal thoracic spine, e.g., thoracic kyphosis and balance, on radiographs has an unknown evidence base. This literature review aims to systematically identify and evaluate the reliability of biomechanical assessments of the sagittal thoracic spine on radiographs used in clinical practice. Methods: The study design was registered with PROSPERO (CRD42023431171). Chiropractic Biophysics Nonprofit, Inc (Eagle, ID, USA) funded this investigation. Inclusion criteria involved studies in English using human subjects, radiography, and reliability analysis of biomechanical analysis of the thoracic spine. Exclusion criteria involved animal and cadaveric studies, phantom mannequins, geometric studies, and non-radiographic studies. This review was conducted using the Peer Review of Electronic Search Strategies (PRESS) checklist to organize the search strategy. A combined approach using Medical Search Headings (MeSH) search terms and a systematic literature review (SLR) search strategy was used. This review followed the recommendations of Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). Databases searched included PubMed, CINAHL, Alt HealthWatch, Web of Science, and a grey literature search. Initial search results produced 990 results. A total of 658 records were screened by two independent reviews and 197 full text articles were assessed for eligibility. Results: Sixty-six studies were included in the final analysis and assessed for methodological quality and bias using the 11-item Quality Appraisal of Diagnostic Reliability (QAREL) tool. A total of 15 studies were of low methodological quality (high risk of bias), 28 were of moderate quality (moderate risk of bias), and 23 were of high quality (low risk of bias). Conclusions: This SLR found most articles investigating the reliability of biomechanical assessment of the sagittal thoracic spine on radiographs to be of moderate-to-high quality and show good-to-excellent reliability.

  • Open Access

    The Reliability of Biomechanical Mensuration Methods of the Sagittal Cervical Spine in Radiography Used in Clinical Practice: A Systematic Review of the Literature

    by Douglas F. Lightstone, Joseph W. Betz, Jason W. Haas, Paul A. Oakley, Joseph R. Ferrantelli, Ibrahim M. Moustafa, Deed E. Harrison

    Background: The biomedical literature assessing the reliability of mensuration of sagittal cervical spine alignment in radiographs has not been systematically evaluated. This review aims to systematically identify and assess reliability studies on biomechanical assessments of the sagittal cervical spine used in clinical practice. Methods: The study design was registered with PROSPERO (CRD42023402990). Funding was obtained from Chiropractic BioPhysics (CBP) Non-Profit (Eagle, ID, USA). Inclusion criteria involved studies in English with: human subjects, radiography of the sagittal cervical spine, and reliability analysis of biomechanical mensuration of the sagittal cervical spine. Exclusion criteria involved studies with: geometric modeling, animals, cadavers, phantom mannequins, and non-radiographic studies. PubMed, CINAHL, AltHealthWatch, and Web of Science databases were searched from inception through to 24 January 2023. The quality appraisal tool for studies of diagnostic reliability (QAREL) assessed bias risk. Results: We followed the synthesis without meta-analysis (SWiM) according to systematic review guidelines. Scrutiny of the inclusion criteria yielded 51 articles. The results were limited due to the heterogeneity of various mensuration methods (Cobb, posterior tangent, translation measures, etc.) and the incorporation of both manual and digital measured assessments. Other sources of heterogeneity included the quality and type of images used, whether digital or plain film radiographs were used, and the differences in statistical analysis and reporting (ICCs or Pearson correlation coefficients, Cohen’s kappa agreement, or Bland–Altman plots). Still, the preponderance of evidence found good-to-excellent reliability. Conclusions: This SROL discovered good-to-excellent intra-examiner reliability for the following biomechanical mensuration methods: intersegmental rotation angles, the thoracic inlet angle, the T1 slope, the C2–C7 posterior tangent method for total cervical lordosis, and the Cobb C2–C7 method for total cervical lordosis. Likewise, using these criteria, we identified good-to-excellent inter-examiner reliability for the following biomechanical mensuration methods: intersegmental rotation angles, the thoracic inlet angle, the T1 slope, translation using the sagittal vertical axis of C2–C7, the C2–C7 posterior tangent method for total cervical lordosis, and the Cobb C2–C7 method for total cervical lordosis.

  • Open Access

    Sensitivity and Specificity of Elliptical Modeling and Sagittal Lumbar Alignment Variables in Normal vs. Acute Low Back Pain Patients: Does Pelvic Morphology Explain Group Lordotic Differences?

    by Paul A. Oakley, Ibrahim M. Moustafa, Joseph W. Betz, Jason O. Jaeger, Deed E. Harrison

    Background/Objectives: The lumbar lordosis (LL) is influenced by pelvic morphology, the unique dimensional characteristics of the pelvis. We investigated the sensitivity and specificity of lumbar sagittal radiographic alignment variables to discriminate between normal controls and acute low back pain (ALBP) patients. Methods: A total of 50 normal controls (29 men; mean age of 27.7 ± 8.5 years) with no history of low back pain and 50 ALBP patients (29 men; 28.1 ± 8 years of age) were compared. Radiographic variables included three measures of LL, a b/a elliptical modeling ratio, sacral base angle (SBA), S1 posterior tangent to vertical (PTS1), two measures of pelvic morphology, as well as three relationships between morphology and LL. Descriptive statistics, linear correlations, and receiver operating characteristic (ROC) curves were calculated. Results: The SBA and Cobb T12-S1 LL were significantly greater in the ALBP group. The SBA showed a reasonable ability to discriminate between the normal and ALBP groups with ROC curve analysis (AUC = 0.67, optimal cut-off value = 41.2°, sensitivity = 0.70, and specificity = 0.62). Pelvic morphology was similar between sex and pain groups. Conclusions: Our sample of ALBP patients had similar pelvic morphology as compared to normal control participants; however, they also demonstrated an increased T12-S1 lordosis and sacral base angle, shown as a hyperlordosis.

  • Open Access

    Reliability of biomechanical mensuration methods of the sagittal cervical spine on radiography used in clinical practice: A systematic review of literature

    by Douglas F. Lightstone, Joseph W. Betz, Jason W. Haas, Paul A. Oakley, Joseph R. Farrentelli, Ibrahim M. Moustafa, Deed E. Harrison

    Biomedical literature assessing reliability of mensuration of sagittal cervical spine alignment on radiographs is limited. This review aims to systematically identify and assess reliability studies on biomechanical assessments of the sagittal cervical spine used in clinical practice. The study design was registered with PROSPERO (CRD42023402990). Funding was from CBP, Non-Profit (Eagle, ID, USA). Inclusion criteria involved studies in English with: human subjects, radiography of the sagittal cervical spine, and reliability analysis on biomechanical mensuration of sagittal cervical spine. Exclusion criteria involved studies with: geometric modeling, animals, cadavers, phantom mannequins, and non-radiographic studies. Pubmed, CINAHL, AltHealth Watch, and Web of Science databases were searched from inception through January 24, 2023. The quality appraisal tool for studies of diagnostic reliability (QAREL) assessed bias risk. Results are presented following the synthesis without meta-analysis (SWiM) in systematic reviews guidelines. Scrutiny of inclusion criteria yielded 51 articles. Results are limited due to heterogeneity of the various mensuration methods and statistical analyses. The preponderance of evidence found good to excellent reliability. The results of this systematic review show that sagittal radiographic mensuration of cervical spine biomechanics and alignment is a reliable method for the diagnosis and management of spine conditions in clinical settings.

  • Open Access

    Reliability of the Biomechanical Assessment of the Sagittal Lumbar Spine and Pelvis on Radiographs Used in Clinical Practice: A Systematic Review of the Literature

    by Joseph W. Betz, Douglas F. Lightstone, Paul A. Oakley, Jason W. Haas, Ibrahim M. Moustafa, Deed E. Harrison

    Background: Biomechanical analysis of the sagittal alignment of the lumbar spine and pelvis on radiographs is common in clinical practices including chiropractic, physical therapy, scoliosis-related thoraco-lumbo-sacral orthosis (TLSO) management, orthopedics, and neurosurgery. Of specific interest is the assessment of pelvic morphology and the relationship between angle of pelvic incidence, sacral slope, and lumbar lordosis to pain, disability, and clinical treatment of spine conditions. The current state of the literature on the reliability of common methods quantifying these parameters on radiographs is limited. Methods: The objective of this systematic review is to identify and review the available studies on the reliability of different methods of biomechanical analysis of sagittal lumbo-pelvic parameters used in clinical practice. Our review followed the recommendations of the preferred reporting items for systematic reviews and meta-analyses (PRISMA). The design of this systematic review was registered with PROSPERO (CRD42023379873). Results: The search strategy yielded a total of 2387 articles. A total of 1539 articles were screened after deduplication and exclusion by automation tools, leaving 473 full-text articles that were retrieved. After exclusion, 64 articles met the inclusion criteria. The preponderance of the evidence showed good to excellent reliability for biomechanical assessment of sagittal lumbo-pelvic spine alignment. Conclusions: The results of this systematic review of the literature show that sagittal radiographic analysis of spinal biomechanics and alignment of the human lumbo-pelvic spine is a reliable tool for aiding diagnosis and management in clinical settings.


  • Open Access

    Sagittal Full-Spine vs. Sectional Cervical Lateral Radiographs: Are the Measurements of Cervical Alignment Interchangeable?

    by Jason W. Haas, Paul A. Oakley, Joseph W. Betz, Jason E. Miller, Jason O. Jaeger, Ibrahim M. Moustafa, Deed E. Harrison

    (1) Background: This study assessed the relationship between cervical spine parameters taken on standing full-spine lateral radiographic images compared to sectional lateral cervical radiographs. (2) Methods: Full-spine (FS) and sectional lateral cervical (LC) radiographs from four spine treatment facilities across the USA retrospectively provided data collected on 220 persons to assess the comparison of three sagittal cervical radiographic measurements between the two views. The measures included cervical lordosis using the absolute rotation angle from C2-C7, sagittal cervical translation of C2-C7, and atlas plane angle to horizontal. Linear correlation and R2 models were used for statistical comparison of the measures for the two views. (3) Results: The mean values of the three measurements were statistically different from each other: C2-C7 translation (FS = 19.84 ± 11.98 vs. LC = 21.18 ± 11.8), C2-C7 lordosis (FS = −15.3 ± 14.63 vs. LC = −18.32 ± 13.16), and atlas plane (FS = −19.99 ± 8.88 vs. LC = −22.56 ± 8.93), where all values were p < 0.001. Weak-to-moderate-to-strong correlations existed between the full-spine and sectional lateral cervical radiographic variables. The R2 values varied based on the measurement were R2 = 0.768 (p < 0.001) for sagittal cervical translation of C2-C7 (strong), R2 = 0.613 (p < 0.001) for the absolute rotation angle C2-C7 (moderate), and R2 = 0.406 (p < 0.001) for the atlas plane line (weak). Though a linear correlation was identified, there were consistent intra-person differences between the measurements on the full spine versus sectional lateral cervical radiographic views, where the full-spine view consistently underestimated the magnitude of the variables. (4) Conclusion: Key sagittal cervical radiographic measurements on the full spine versus sectional lateral cervical radiographic views show striking intra-person differences. The findings of this study confirm that full spine versus sectional lateral cervical radiographic views provide different biomechanical magnitudes of cervical sagittal alignment, and caution should be exercised by health care providers as these are not interchangeable. We recommend the LC view for measurement of cervical sagittal alignment variables.


  • Open Access

    Can the Mismatch of Measured Pelvic Morphology vs. Lumbar Lordosis Predict Chronic Low Back Pain Patients?

    by Deed E. Harrison, Jason W. Haas, Ibrahim M. Moustafa, Joseph W. Betz, Paul A. Oakley

    Background: Measures of lumbar lordosis (LL) and elliptical modeling variables have been shown to discriminate between normal and chronic low back pain (CLBP) patients. Pelvic morphology influences an individual’s sagittal lumbar alignment. Our purpose is to investigate the sensitivity and specificity of lumbar sagittal radiographic alignment and modeling variables to identify if these can discriminate between normal controls and CLBP patients. Methods: We conducted a computer analysis of digitized vertebral body corners on lateral lumbar radiographs of normal controls and CLBP patients. Fifty normal controls were attained from a required pre-employment physical examination (29 men; 21 women; mean age of 27.7 ± 8.5 years), with no history of low back pain, a normal spinal examination, no pathologies, anomalies, or instability. Additionally, 50 CLBP patients (29 men; 29.5 ± 8 years of age) were randomly chosen and matched to the characteristics of the controls. The inclusion criteria required no abnormalities on lumbar spine radiographs. The parameters included the following: ARA L1-L5 lordosis, ARA T12-S1 lordosis, Cobb T12-S1, b/a elliptical modelling ratio, sacral base angle (SBA), and S1 posterior tangent to vertical (PTS1). Two measures of pelvic morphology were determined for each person—the angle of pelvic incidence (API) and posterior tangent pelvic incidence angle (PTPIA)—and the relationships between API − ARA T12-S1, API − Cobb T12-S1, and API − ARA L1-5 was determined. Descriptive statistics and correlations among the primary variables were determined. The receiver operating characteristic curves (ROC curves) for primary variables were analyzed. Results: The mean values of LL were statistically different between the normal and CLBP groups (p < 0.001), indicating a hypo-lordotic lumbar spine for the CLBP group. The mean b/a ratio was lower in the chronic pain group (p = 0.0066). The pelvic morphology variables were similar between the groups (p > 0.05). API had a stronger correlation to the SBA and Cobb T12-S1 than PTPIA did, while PTPIA had a stronger correlation to the S1 tangent and ARA T12-S1 than API did. While CLBP patients had a stronger correlation of ARA T12-S1 and Cobb T12-S1 relative to the pelvic morphology, they also had a reduced correlation of ARA L1-L5 lordosis relative to their SBA and pelvic morphology measures. API − T12-S1, API − L1-L5, and API − Cobb T12-S1 were statistically different between the groups, p < 0.001. Using ROC curve analyses, it was identified that ARA L1-L5 lordosis of 36° and ARA T12-S1 of 68° have a good sensitivity and specificity to discriminate between normal and CLBP patients. ROC curve analyses identified that lordosis ARAT12-S1 < 68° (AUC = 0.83), lordosis ARAL1-L5 < 36° (AUC = 0.78), API − ARA T12-S1 < −18° (AUC = 0.75), API − ARAL1-L5 > 35° (AUC = 0.71), and API − Cobb T12-S1 < −5° (AUC = 0.69) had moderate to good discrimination between groups (AUC = 0.83, 0.78, 0.75, and 0.72). Conclusions: Pelvic morphology is similar between normal and CLBP patients. CLBP patients have an abnormal ‘fit’ of their API − ARAT12-S1 and L1-L5 lumbar lordosis relative to their pelvic morphology and sacral tilt shown as a hypolordosis.


  • Open Access

    Two Methods of Forward Head Posture Assessment: Radiography vs. Posture and Their Clinical Comparison

    by Paul A. Oakley, Ibrahim M. Moustafa, Jason W. Haas, Joseph W. Betz, Deed E. Harrison

    Background: Forward head posture (FHP) and altered cervical lordotic curvatures are common spine displacements often associated with neck pain and disability. Two primary categories for determining FHP exist: radiographic and postural measurements. Methods: This study investigated the correlation between the craniovertebral angle (CVA), the radiographically measured C2–C7 sagittal vertical axis (SVA), and cervical lordosis (absolute rotation angle: ARA C2–C7) in a sample of participants with chronic myofascial pain (CMP). In 120 participants, we performed both a postural measurement of the CVA and a lateral cervical radiograph, where the C2–C7 SVA and ARA C2–C7 were measured. A linear-regression R2 value to assess the correlation between the CVA, C2–C7 SVA, and ARA C2–C7 was sought. Results: A statistically significant weak linear fit was identified (Spearman’s r = 0.549; R2 = 0.30, p < 0.001) between the CVA and C2–C7 SVA, having considerable variation between the two measures. A statistically significant linear fit (very weak) was identified for the lordosis ARA C2–C7 and the CVA: Spearman’s r = 0.524; R2 = 0.275; p < 0.001. A value of 50° for the CVA corresponded to a value of 20 mm for the C2–C7 SVA on an X-ray. Conclusion: While the CVA and radiographic C2–C7 SVA are weakly correlated in an individual, they seem to represent different aspects of sagittal cervical balance. The CVA cannot replace radiographically measured cervical lordosis. We recommend that more emphasis be given to radiographic measures of sagittal cervical alignment than the CVA when considering patient interventions.