Xiao Guan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xiao Guan has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Jiandong Duan
School of Electrical Engineering, Xi’an University of Technology, Xi’an 710048, China
4 shared publications - Ming Zhao
School of Electrical Engineering, Xian University of Technology, Xian, Shaanxi, China
4 shared publications - Wenchao Lu
School of Electrical Engineering, Xian University of Technology, Xian, Shaanxi, China
3 shared publications - Chul-Hwan Kim
Department of Electrical and Electronic Engineering, Sungkyunkwan University, Suwon, Republic of Korea
1 shared publication - Fengyi Li
School of Electrical Engineering, Xian University of Technology, Xian, China
1 shared publication Kunxiong Liu
State Grid Shaanxi Electric Power Company Limited, Xian Ankang, Shaanxi, China
1 shared publication
Latest Publications
- 1 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Transient Modeling of CVT and Identification Method for Stray Capacitance Parameters Based on Limited Information of Resonance Points
The presence of stray capacitance seriously affects the accuracy of capacitor voltage transformers (CVTs) in measuring transient wideband signals. However, for transient signal measurement, it is difficult to determine the initial calculation conditions for the stray parameters of the physical model, and the accuracy of the stray parameter acquisition method based on intelligent algorithms is poor. A identification method of CVT stray capacitance parameters using limited resonance point information is proposed in this paper. The method is based on the resonance mechanism of the CVT and identifies each stray capacitance parameter in a novel two steps. The accuracy of the proposed method is evaluated by simulation tests in terms of identification error of stray capacitance parameters and fitting results of CVT wideband transfer characteristics, respectively. The accuracy superiority of the proposed method, compared to the overall identification method which is currently widely adopted. Finally, the operation impulse experimental system for the obtainment of CVT wideband transfer characteristics was designed. The experimental results further verify the feasibility and accuracy of proposed method for obtaining stray capacitance parameters of onsite CVT devices, demonstrating its advantage in reducing testing workload.
- 1 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Transient Modeling of CVT and Identification Method for Stray Capacitance Parameters Based on Limited Information of Resonance Points
The presence of stray capacitance seriously affects the accuracy of capacitor voltage transformers (CVTs) in measuring transient wideband signals. However, for transient signal measurement, it is difficult to determine the initial calculation conditions for the stray parameters of the physical model, and the accuracy of the stray parameter acquisition method based on intelligent algorithms is poor. A identification method of CVT stray capacitance parameters using limited resonance point information is proposed in this paper. The method is based on the resonance mechanism of the CVT and identifies each stray capacitance parameter in a novel two steps. The accuracy of the proposed method is evaluated by simulation tests in terms of identification error of stray capacitance parameters and fitting results of CVT wideband transfer characteristics, respectively. The accuracy superiority of the proposed method, compared to the overall identification method which is currently widely adopted. Finally, the operation impulse experimental system for the obtainment of CVT wideband transfer characteristics was designed. The experimental results further verify the feasibility and accuracy of proposed method for obtaining stray capacitance parameters of onsite CVT devices, demonstrating its advantage in reducing testing workload.
- 24 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
A Method of Measuring Switching Overvoltage Based on the CVT Capacitive Current Integration Principle
Switching overvoltage will destroy the resonance condition inside the capacitor voltage transformer (CVT), reducing the accuracy of the CVT measurement of switching overvoltage. Some methods can accurately measure the switching overvoltage, but they need to modify the CVT structure, the operation process is complex and expensive. To solve this problem, this paper proposes a switching overvoltage measurement method based on the CVT capacitive current integration principle. This method uses the compound Simpson integration algorithm to integrate the capacitive current to realize the measurement of the switching overvoltage. On this basis, the effect of capacitive current data loss and the initial value of voltage integration on this method is considered to improve the measurement accuracy. Furthermore, the accuracy of this method for measuring the switching overvoltage is verified by simulations and experiments. Compared to other methods, this method has the advantage of a simple measurement principle, lower transformation complexity, and easy implementation.
- 24 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
A Method of Measuring Switching Overvoltage Based on the CVT Capacitive Current Integration Principle
Switching overvoltage will destroy the resonance condition inside the capacitor voltage transformer (CVT), reducing the accuracy of the CVT measurement of switching overvoltage. Some methods can accurately measure the switching overvoltage, but they need to modify the CVT structure, the operation process is complex and expensive. To solve this problem, this paper proposes a switching overvoltage measurement method based on the CVT capacitive current integration principle. This method uses the compound Simpson integration algorithm to integrate the capacitive current to realize the measurement of the switching overvoltage. On this basis, the effect of capacitive current data loss and the initial value of voltage integration on this method is considered to improve the measurement accuracy. Furthermore, the accuracy of this method for measuring the switching overvoltage is verified by simulations and experiments. Compared to other methods, this method has the advantage of a simple measurement principle, lower transformation complexity, and easy implementation.
- 20 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
A Novel Transient Saturation Detection Method for P-Class Current Transformer Using Improved Hausdorff Distance Algorithm
The P-class current transformer (CT) widely used at present creates the problem that transient saturation occurs and leads to the reduction of the reliability of the differential protection of the transformer or even false operation. This paper proposes a novel CT saturation detection method to avoid differential protection false operation. Firstly, based on the dynamic regional saturation J-A model, CT transient saturation characteristics are analyzed. These characteristics are extracted and represented using the improved Hausdorff distance algorithm, which constructs the detection scheme for CT transient saturation. The simulation tests demonstrate that the proposed scheme is feasible and rapid in various work conditions such as fault types, initial phase angle, voltage rising amplitude and Gaussian noise signal, compared with the other saturation detection schemes. Finally, a series of fielded experiments up to 48 kA current are conducted on 330 kV P-class CTs. The large current dynamic experiments verify the proposed CT saturation detection method is valid and applicable to practical engineering, which ensures the transformer differential protection is reliable.
- 20 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
A Novel Transient Saturation Detection Method for P-Class Current Transformer Using Improved Hausdorff Distance Algorithm
The P-class current transformer (CT) widely used at present creates the problem that transient saturation occurs and leads to the reduction of the reliability of the differential protection of the transformer or even false operation. This paper proposes a novel CT saturation detection method to avoid differential protection false operation. Firstly, based on the dynamic regional saturation J-A model, CT transient saturation characteristics are analyzed. These characteristics are extracted and represented using the improved Hausdorff distance algorithm, which constructs the detection scheme for CT transient saturation. The simulation tests demonstrate that the proposed scheme is feasible and rapid in various work conditions such as fault types, initial phase angle, voltage rising amplitude and Gaussian noise signal, compared with the other saturation detection schemes. Finally, a series of fielded experiments up to 48 kA current are conducted on 330 kV P-class CTs. The large current dynamic experiments verify the proposed CT saturation detection method is valid and applicable to practical engineering, which ensures the transformer differential protection is reliable.
- 8 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
A Novel Method for CVT Transient Transform Characteristics Improvement Integrated With Digital Filter Suppressing Voltage Oscillation
Capacitive voltage transformer (CVT) transient transform characteristics destroy the linear relationship between output voltage and input voltage, leading to a sharp increase in measurement error. To address this issue, this article proposed an indirect method to design an infinite impulse response (IIR) filter to suppress the voltage oscillation amplitude caused by the CVT transient transformation characteristics. The method derives the CVT transfer function using the cascade form. Determining the compensating reactor frequency response curve, the intermediate transformer frequency response curve, and the oscillatory components below 50 Hz caused by ferromagnetic resonance as the design targets, IIR filters were designed to suppress the voltage oscillation amplitude. The proposed method’s effectiveness is verified by simulation in suppressing the voltage oscillation amplitude when transient response and ferromagnetic resonance occur. The simulation results show that the output voltage amplitude can be suppressed below 0.5 V after 0.48 s in the transient response, and the voltage oscillation amplitude caused by ferromagnetic resonance can be suppressed well under different short-circuit durations. This method also reduces the output voltage oscillation time and improves the CVT voltage measurement accuracy.
- 8 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
A Novel Method for CVT Transient Transform Characteristics Improvement Integrated With Digital Filter Suppressing Voltage Oscillation
Capacitive voltage transformer (CVT) transient transform characteristics destroy the linear relationship between output voltage and input voltage, leading to a sharp increase in measurement error. To address this issue, this article proposed an indirect method to design an infinite impulse response (IIR) filter to suppress the voltage oscillation amplitude caused by the CVT transient transformation characteristics. The method derives the CVT transfer function using the cascade form. Determining the compensating reactor frequency response curve, the intermediate transformer frequency response curve, and the oscillatory components below 50 Hz caused by ferromagnetic resonance as the design targets, IIR filters were designed to suppress the voltage oscillation amplitude. The proposed method’s effectiveness is verified by simulation in suppressing the voltage oscillation amplitude when transient response and ferromagnetic resonance occur. The simulation results show that the output voltage amplitude can be suppressed below 0.5 V after 0.48 s in the transient response, and the voltage oscillation amplitude caused by ferromagnetic resonance can be suppressed well under different short-circuit durations. This method also reduces the output voltage oscillation time and improves the CVT voltage measurement accuracy.