CZCristina Zapater

Cristina Zapater

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Cristina Zapater has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Antonio Canals

    Department of Analytical Chemistry Nutrition and Food Science and University Institute of Materials Faculty of Science University of Alicante P.O. Box 99 03080 Alicante Spain

    4 shared publications
  • Lorena Vidal

    Department of Analytical Chemistry Nutrition and Food Science and University Institute of Materials Faculty of Science University of Alicante P.O. Box 99 03080 Alicante Spain

    4 shared publications
  • Miguel Ángel Aguirre

    Department of Analytical Chemistry, Nutrition and Food Science and University Institute of Materials, Faculty of Science, University of Alicante, P.O. Box 99, 03080, Alicante, Spain

    3 shared publications
  • Domenech Josep Ramon

    Department of Organic Chemistry, Institute of Organic Synthesis (ISO), University of Alicante, 03080 Alicante, Spain

    2 shared publications
  • Miguel Ángel Aguirre

    Department of Analytical Chemistry Nutrition and Food Science and University Institute of Materials Faculty of Science University of Alicante P.O. Box 99 03080 Alicante Spain

    1 shared publication
  • Nerea González-Gallardo

    Department of Organic Chemistry and Institute of Organic Synthesis (ISO), Faculty of Sciences, University of Alicante, PO Box 99, 03080, Alicante, Spain

    1 shared publication

Latest Publications

  • Open Access

    Influence of the Surface Container Nature on the Magnetic Properties of a Magnetic Eutectic Mixture

    by Cristina Zapater, Miguel Ángel Aguirre, Lorena Vidal, Antonio Canals

    The effect of polypropylene and glass materials on the magnetic properties of a magnetic eutectic mixture (MEM) composed of iron chloride hexahydrate (FeCl 3 ·6H 2 O) and ethylene glycol (EG) (i.e., FeCl 3 ·6H 2 O:EG, molar ratio of 1:2) has been investigated. In both materials, magnetization (M) curves at 300 and 358 K and effect of temperature are studied. As a result, MEM exhibits paramagnetic behavior. However, MEM on polypropylene exhibits a higher slope of the linear fit at 300 K (i.e., 4.03 × 10 −6 emu g −1 Oe −1 ) compared to 358 K (i.e., 1.90 × 10 −6 emu g −1 Oe −1 ) and a decrease of its M with increasing temperature. Conversely, MEM on glass exhibits a lower slope of the linear fit at 300 K (i.e., 4.05 × 10 −6 emu g −1 Oe −1 ) compared to 358 K (i.e., 4.55 × 10 −6 emu g −1 Oe −1 ), remaining practically stable at higher temperatures. Notably, magnetization on polypropylene (i.e., 4.46 × 10 −2 emu g −1 ) is higher at room temperature than that of glass (i.e., 3.86 × 10 −2 emu g −1 ), whereas at synthesis temperature, glass shows a higher magnetization (i.e., 3.75 × 10 −2 emu g −1 ) compared to polypropylene (i.e., 3.43 × 10 −2 emu g −1 ). These findings underscore the influence of surface containers on the magnetic properties of MEM, which should be considered when selecting materials for specific chemical applications.


  • Ethylene glycol-based dispersive liquid-liquid microextraction of bisphenols in edible oil samples

    by Cristina Zapater, Lorena Vidal, Miguel Ángel Aguirre, Antonio Canals


  • Open Access

    Tunable Properties of Non‐Volatile Magnetic Mixtures on Different Surfaces

    by Sergio J. Abellán‐Martín, Cristina Zapater, Nerea González‐Gallardo, Miguel Ángel Aguirre, Lorena Vidal, Diego J. Ramón, Antonio Canals

    In this work, the surface nature‐dependent behaviors of magnetic deep eutectic solvents (MDESs) and magnetic low‐transition‐temperature non‐volatile mixtures (MLTTMs) are reported for the first time. It has been observed that the surface of the material where the MDES or the MLTTM is placed could considerably affect the dispersion and the magnetic and structural properties of these magnetic mixtures. Different techniques and analyses have been carried out to highlight the differences observed in the properties depending on the material on which these magnetic mixtures are placed. To that end, differential scanning calorimetry (DSC), surface tension, contact angle and scanning electron microscopy with energy dispersive X‐ray spectroscopy (SEM‐EDX) measurements have been performed. As a result, it has been shown that the MDESs or MLTTMs are retained and adhered to glass surfaces, resulting in a loss of magnetism of the mixture in addition to a loss in the performance of synthesis carried out on the closeness of glass materials as the interaction between the glass and the mixture modify the composition and therefore the properties. As a preliminary result, when using these magnetic mixtures as extractant solvents in dispersive liquid‐liquid microextraction, the MDES or MLTTM is retained on the walls of the glass tubes reducing the extraction efficiency, repeatability and the extraction recovery using an external magnetic field. For all these reasons, polypropylene materials should be recommended when handling magnetic deep eutectic solvents and non‐volatile MLTTMs.