GCGabriela Pilz da Cunha

Gabriela Pilz da Cunha

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Gabriela Pilz da Cunha has a total of 172 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparative diagnostic performance and safety of indocyanine green versus superparamagnetic iron oxide and Technetium-99m for sentinel lymph node biopsy in breast cancer: a systematic review and meta-analysis

    by Tessa L. Dinger, Patrick E. Goldhawk-White, Kevin P. White, Gabriela Pilz da Cunha, Vassilis Pitsinis, Annemiek Doeksen

    Background: Technetium-99 m ( 99m Tc) is the current standard of care for sentinel lymph node (SLN) biopsy in early breast cancer. Non-radioactive alternatives such as indocyanine green (ICG) and superparamagnetic iron oxide (SPIO) compounds have demonstrated non-inferior and, in some studies, superior SLN detection rates compared with 99m Tc. Given that ICG offers safety advantages over SPIO, it is important to understand their comparative performance. As no studies have directly compared ICG and SPIO, this study aimed to indirectly compare these tracers through separate comparisons with 99m Tc. Materials and methods: Two systematic reviews and meta-analyses were conducted, comparing ICG versus 99m Tc and SPIO versus 99m Tc. An indirect comparison of ICG and SPIO assessed non-inferiority and superiority. Primary outcomes were per-case and per-node SLN detection and sensitivity for pathological SLNs, presented as odds ratios (ORs) with 95% confidence intervals (CIs). Secondary outcomes included tracer-related adverse events. Results: Across 26 studies, ICG ( n = 3105) outperformed 99m Tc ( n = 3219) in per-case detection (OR = 1.48; 95% CI: 1.00–2.19; P = 0.049), per-node detection (OR = 4.00; 95% CI: 2.00–8.01; P < 0.001), and pathological sensitivity (OR = 2.35; 95% CI: 1.50–3.68; P < 0.001). Meta-analysis of 20 studies showed that SPIO ( n = 2093) was superior to 99m Tc ( n = 2092) only for per-node detection (OR = 1.59; 95% CI: 1.06–2.39; P = 0.025). Indirect comparison showed that ICG was superior to SPIO for both per-case ( P = 0.005) and per-node detection ( P < 0.001), with non-inferior pathological sensitivity. No ICG-related adverse events were reported, whereas SPIO caused bronze skin staining in 23.4% of patients ( P < 0.001). Conclusion: ICG demonstrated superior diagnostic performance compared with both 99m Tc and SPIO, and was associated with fewer tracer-related adverse events than SPIO. However, direct comparisons between ICG and SPIO are needed to strengthen this conclusion.

  • Laparoscopic Versus Open Liver Resection for Colorectal Liver Metastases

    by Bram Olij, Gabriela Pilz da Cunha, Siân A. Pugh, Mohammad Abu Hilal, Víctor Lopez-Lopez, Davit Aghayan, Roberto Brusadin, Robert S. Fichtinger, Francesca Ratti, Christoph Kuemmerli, et al.

  • Open Access

    Nationwide strategies and outcomes of minimally invasive versus open combined liver ablation and resection for colorectal liver metastases

    by Gabriela Pilz da Cunha, Ketharan Balasupramaniam, Niels Kok, Cornelis Verhoef, Paul D. Gobardhan, Eric R. Manusama, Maxime J.L. Dewulf, Christiaan van der Leij, Eric J.T. Belt, J. Sven D. Mieog, et al.

  • Open Access

    Staged introduction of a first-in-human concomitant robotic liver resection and cone-beam CT-guided percutaneous liver ablation in a hybrid operating room (HARMONY): an IDEAL stage 0/1 study

    by Gabriela Pilz da Cunha, Hannah H Schulz, Tijs J Hoogteijling, Maarten Lj Smits, Katrin Stoecklein, Martijn R Meijerink, Rutger-Jan Swijnenburg

    Objectives: To perform the first-in-human concomitant robotic liver resection and cone-beam CT (CBCT)-guided ablation in a hybrid operating room (HARMONY). Design: IDEAL stage 0/1 study outlining the preparatory steps and outcomes of the first-in-human HARMONY procedure. IDEAL stage 0 involved conceptualisation, team training and dry runs. The first HARMONY procedure was performed and the procedural technique is described in detail. Setting: All procedures took place at a single academic medical centre. Participants: Patients eligible for the HARMONY procedure are any adults eligible for combined ablation and resection of colorectal liver metastases. The HARMONY procedure was performed in a first patient. Outcomes of patients who underwent sequential robotic liver resection and CT hepatic arteriography-guided liver ablation in the preparatory phase are also reported. Intervention: Concomitant robotic liver resection and CBCT-guided ablation in a hybrid operating room. Main outcome measures: The primary outcome was technical feasibility of the HARMONY procedure defined as the technical success of both the robotic surgical resection and CBCT-guided ablation within the hybrid operating room. Results: Between 2018 and 2024, 19 patients underwent sequential robotic liver resection and CT-guided ablation. Median interval between procedures was 4 days, with 36.8% treated during one admission. Intraoperative incidents occurred in three (15.8%) patients and two (10.5%) patients experienced severe complications requiring reintervention. The first-in-human HARMONY procedure was successfully completed without intraoperative complications. Conclusions: The concomitant performance of robotic liver resection and CBCT-guided ablation is technically feasible in a hybrid operating room. Future studies should evaluate its reproducibility, safety and long-term outcomes. Trial registration number: CCMO Research with human participants (NL-009169).

  • Open Access

    Practice Patterns and Implementation of Combined Ablation and Resection (CARe) Strategies for Colorectal Liver Metastases: A Pan-European Survey

    by Gabriela Pilz da Cunha, Hannah Schulz, Niels F.M. Kok, Martijn R. Meijerink, Rutger-Jan Swijnenburg

  • Top Cited Papers
    Open Access

    Robotic versus laparoscopic liver resection: a systematic review and meta-analysis of comparative studies

    by Gabriela Pilz da Cunha, Tijs J. Hoogteijling, Marc G. Besselink, Mohammad N. Alzoubi, Rutger-Jan Swijnenburg, Mohammad Abu Hilal

    Background: The technical advantages of robotic platforms may facilitate minimally invasive liver resections, improving outcomes over the laparoscopic approach. This meta-analysis aimed to compare outcomes of robotic liver resection (RLR) versus laparoscopic liver resection (LLR). Materials and Methods: A systematic literature search identified matched cohort studies and randomized controlled trials comparing RLR and LLR from 2003 to 2024. Studies concerning transplant hepatectomy and retrospective studies with fewer than 50 patients per group were excluded. Perioperative outcomes were analyzed in a meta-analysis, with subgroup analyses for minor anterolateral (AL), minor posterosuperior (PS), and major resections. Results: Overall, 31 studies with 8989 patients undergoing RLR and 43 474 LLR were included, with 8207 RLRs and 9763 LLRs after matching. RLR was associated with lower conversion (RR 0.41 [95% CI, 0.32–0.52]), overall morbidity (RR 0.92 [95% CI, 0.84–1.00]), and severe morbidity rate (RR 0.81 [95% CI, 0.70–0.94]), as well as higher rates of R0 resection (RR 1.02 [95% CI, 1.01–1.03]) and readmission (RR 1.24 [95% CI, 1.09–1.41]). There were no significant differences in blood loss, transfusion, Pringle use, operative time, hospital stay, and mortality. RLR reduced blood loss in minor AL and PS resections, with fewer transfusions also observed in minor AL. RLR was associated with shorter hospital stays in minor PS resections. Notably, RLR was associated with less overall morbidity in minor AL and less severe morbidity in major resections. Available results on long-term oncological outcomes were not suitable for meta-analysis. Conclusions: RLR demonstrates advantages in several key perioperative outcomes compared to LLR across the full spectrum of liver resection complexity.


  • Open Access

    A European expert consensus surgical technique description for robotic hepatectomy

    by Gabriela Pilz da Cunha, Daan J. Lips, Jawad Ahmad, Niclas Kvarnström, Luca Aldrighetti, Mathieu D’hondt, Jeroen Hagendoorn, Rutger-Jan Swijnenburg

    Video 1 Surgical technique for robotic hepatectomy. Authors: Gabriela Pilz da Cunha, Daan J. Lips, Jawad Ahmad, Niclas Kvarnström, Luca Aldrighetti, Mathieu D’Hondt, Jeroen Hagendoorn, Rutger-Jan Swijnenburg


  • Open Access

    Surgical technique for fully robotic two-stage hepatectomy using indocyanine green fluorescence imaging for bilobar colorectal liver metastases

    by Babette I. Kuiper, Gabriela Pilz da Cunha, Burak Görgec, Jan J. J. de Vries, Joris Erdmann, Geert Kazemier, Barbara M. Zonderhuis, Rutger-Jan Swijnenburg

    Surgical resection remains the most effective treatment for colorectal liver metastases (CRLM). In recent years, the feasibility of liver resection for extensive CRLM expanded due to two-stage hepatectomy techniques. In experienced hands, these complex operations can be performed using minimally invasive techniques, such as robotics, and facilitated by image-guided surgery using indocyanine green (ICG) fluorescence imaging. The objective of this report is to present the surgical technique of a fully robotic two-stage hepatectomy using ICG fluorescence imaging. We present a patient with extensive, bilobar CRLM, eligible for local surgical treatment following induction systemic chemotherapy. Both the first and second stage procedures were performed robotically using ICG-fluorescence imaging for resection margin guidance. The key steps, of both procedures, are outlined in step-by-step surgical technique descriptions detailing patient positioning, trocar placement, instrument use, Pringle maneuver, and parenchymal transection technique. Tips and tricks, critical to performing the procedures safely and successfully, include careful patient selection to match surgeon skill and experience as well as use of ICG and intraoperative ultrasound for intraoperative guidance. The patient recovered from both surgeries quickly without major complications. This report shows that robotic ICG fluorescence-guided two-stage hepatectomy seems to be a safe and feasible procedure for treatment of bilobar CRLM.

  • Open Access

    Risk factors and outcomes of conversions in robotic and laparoscopic liver resections: A nationwide analysis

    by Gabriela Pilz da Cunha, Jasper P. Sijberden, Paul Gobardhan, Daan J. Lips, Türkan Terkivatan, Hendrik A. Marsman, Gijs A. Patijn, Wouter K.G. Leclercq, Koop Bosscha, J. Sven D. Mieog, et al.


  • Open Access

    Healthcare cost expenditure for robotic versus laparoscopic liver resection: a bottom-up economic evaluation

    by Gabriela Pilz da Cunha, Veerle M.H. Coupé, Barbara M. Zonderhuis, H. Jaap Bonjer, Joris I. Erdmann, G. Kazemier, Marc G. Besselink, Rutger-Jan Swijnenburg