YWYihan Wang

Yihan Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yihan Wang has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Subject-Adaptive EEG-EMG Fusion Network for Motor Intention Decoding Across a Broad Impairment Spectrum

    by Yihan Wang, Jiaxing Wang, Weiqun Wang, Jianqiang Su, Bin Hu, Yuze Feng, Shuai Han, Hao Li, Jianghong He, Zeng-Guang Hou

    The fusion of electroencephalography (EEG) and electromyography (EMG) holds significant potential for clinical motor intention decoding. However, existing methods are constrained by the dual challenges of data scarcity and high physiological heterogeneity across patient populations. To address these limitations, this paper proposes the Brain-Muscle based Motor Planning to Execution Network (BM-MP2E), a framework leveraging brain-muscle complementarity to ensure reliable decoding across the full impairment spectrum. We introduce a physiologically-informed architecture that explicitly mirrors the neuromuscular transmission pathway. Specifically, movement-related cortical potential (MRCP) for motor planning, αβ bands for activation, and EMG for execution are extracted to constrain the model’s solution space. Furthermore, a subject-adaptive fusion module is designed to dynamically modulate modality contributions based on individual functional status. Experimental validation on 21 patients (ranging from Disorders of Consciousness to stroke) in a unimanual five-class task demonstrates that BM-MP2E achieves an average accuracy of 60.81%, yielding a 6.94% improvement over single-modality EMG. The average learned weights were 0.265 (MRCP), 0.323 (αβ), and 0.412 (EMG). Quantitative analysis reveals a strong positive correlation between adaptive EMG weights and motor function scores (r =0.884, p < 0.0001). This confirms a compensatory measurement logic: the system automatically prioritizes stable cortical features in severe cases while progressively leveraging high-fidelity peripheral signals as function recovers. These findings validate BM-MP2E as an adaptive clinical solution capable of facilitating motor assistance across the entire recovery spectrum.

  • A Flexible Low-Voltage Electrical Stimulation System for Precise and Personalized Whole-Hand Tactile Feedback

    by Jianqiang Su, Jiaxing Wang, Weiqun Wang, Bin Hu, Yihan Wang, Yuze Feng, Hezhong Yan, Zhengqing Wang, Zeng-Guang Hou

    Tactile feedback is crucial for precise hand manipulation in human-machine interaction, which can improve task performance and enhance user immersion. However, due to the high impedance of the stratum corneum and the spatial variability of tactile sensitivity, how to provide vivid and consistent electrical tactile feedback for the whole hand within a low and safe voltage range remains a challenge. This study developed a flexible and low-voltage electrotactile feedback system to induce precise and personalized tactile sensations. Firstly, to achieve safe tactile stimulation under low-voltage conditions, the system used a high-frequency biphasic square wave modulated by a sine signal to penetrate the skin and stimulate nerves. Secondly, considering the dexterity and complexity of the hand, a high-density flexible electrode patch was designed to fit the hand contour, ensuring stable contact and localized stimulation. Finally, to provide personalized and realistic tactile sensation, the system applied stimulation with tailored parameters to different hand regions based on sensitivity characteristics. Thresholds of four sensation levels were measured in nine participants across different frequencies, with a minimum average detectable voltage as low as 10.7 V. Moreover, virtual tactile sensations associated with grasping objects of different shapes could be simulated, and participants achieved 97.2% accuracy in identifying six fine gestures using tactile cues alone. The system could also be integrated with virtual reality to provide a more immersive experience through dynamic and real-time tactile feedback. These phenomena demonstrated the potential of the proposed tactile system for applications in wearable and interactive systems.


  • Enhanced Cross-Subject Classification of Hybrid EEG-fNIRS Data Using the Simplified Multimodal Transformer Network

    by Chayut Bunterngchit, Jiaxing Wang, Jianqiang Su, Yihan Wang, Shiqi Liu, Zeng-Guang Hou


  • Temporal attention fusion network with custom loss function for EEG–fNIRS classification

    by Chayut Bunterngchit, Jiaxing Wang, Jianqiang Su, Yihan Wang, Shiqi Liu, Zeng-Guang Hou

    Objective. Methods that can detect brain activities accurately are crucial owing to the increasing prevalence of neurological disorders. In this context, a combination of electroencephalography (EEG) and functional near-infrared spectroscopy (fNIRS) offers a powerful approach to understanding normal and pathological brain functions, thereby overcoming the limitations of each modality, such as susceptibility to artifacts of EEG and limited temporal resolution of fNIRS. However, challenges such as class imbalance and inter-class variability within multisubject data hinder their full potential. Approach. To address this issue, we propose a novel temporal attention fusion network (TAFN) with a custom loss function. The TAFN model incorporates attention mechanisms to its long short-term memory and temporal convolutional layers to accurately capture spatial and temporal dependencies in the EEG–fNIRS data. The custom loss function combines class weights and asymmetric loss terms to ensure the precise classification of cognitive and motor intentions, along with addressing class imbalance issues. Main results. Rigorous testing demonstrated the exceptional cross-subject accuracy of the TAFN, exceeding 99% for cognitive tasks and 97% for motor imagery (MI) tasks. Additionally, the ability of the model to detect subtle differences in epilepsy was analyzed using scalp topography in MI tasks. Significance. This study presents a technique that outperforms traditional methods for detecting high-precision brain activity with subtle differences in the associated patterns. This makes it a promising tool for applications such as epilepsy and seizure detection, in which discerning subtle pattern differences is of paramount importance.


  • TFTL: A Task-Free Transfer Learning Strategy for EEG-Based Cross-Subject and Cross-Dataset Motor Imagery BCI

    by Yihan Wang, Jiaxing Wang, Weiqun Wang, Jianqiang Su, Chayut Bunterngchit, Zeng-Guang Hou

    Objective: Motor imagery-based brain-computer interfaces (MI-BCIs) have been playing an increasingly vital role in neural rehabilitation. However, the long-term task-based calibration required for enhanced model performance leads to an unfriendly user experience, while the inadequacy of EEG data hinders the performance of deep learning models. To address these challenges, a task-free transfer learning strategy (TFTL) for EEG-based cross-subject & cross-dataset MI-BCI is proposed for calibration time reduction and multi-center data co-modeling. Methods: TFTL strategy consists of data alignment, shared feature extractor, and specific classifiers, in which the label predictor for MI tasks classification, as well as domain and dataset discriminator for inter-subject variability reduction are concurrently optimized for knowledge transfer from subjects across different datasets to the target subject. Moreover, only resting data of the target subject is used for subject-specific model construction to achieve task-free. Results: We employed three deep learning methods (ShallowConvNet, EEGNet, and TCNet-Fusion) as baseline approaches to evaluate the effectiveness of the proposed strategy on five datasets (BCIC IV Dataset 2a, Dataset 1, Physionet MI, Dreyer 2023, and OpenBMI). The results demonstrate a significant improvement with the inclusion of the TFTL strategy compared to the baseline methods, reaching a maximum enhancement of 15.67% with a statistical significance (p = 2.4e-5 < 0.05). Moreover, task-free resulted in MI trials needed for calibration being 0 for all datasets, which significantly alleviated the calibration burden for patients before usage. Conclusion/Significance: The proposed TFTL strategy effectively addresses challenges posed by prolonged calibration periods and insufficient EEG data, thus promoting MI-BCI from laboratory to clinical application.


  • Open Access

    An Adaptive Hybrid Brain–Computer Interface for Hand Function Rehabilitation of Stroke Patients

    by Jianqiang Su, Jiaxing Wang, Weiqun Wang, Yihan Wang, Chayut Bunterngchit, Pu Zhang, Zeng-Guang Hou

    Motor imagery (MI) based brain computer interface (BCI) has been extensively studied to improve motor recovery for stroke patients by inducing neuroplasticity. However, due to the lower spatial resolution and signal-to-noise ratio (SNR) of electroencephalograph (EEG), MI based BCI system that involves decoding hand movements within the same limb remains lower classification accuracy and poorer practicality. To overcome the limitations, an adaptive hybrid BCI system combining MI and steady-state visually evoked potential (SSVEP) is developed to improve decoding accuracy while enhancing neural engagement. On the one hand, the SSVEP evoked by visual stimuli based on action-state flickering coding approach significantly improves the recognition accuracy compared to the pure MI based BCI. On the other hand, to reduce the impact of SSVEP on MI due to the dual-task interference effect, the event-related desynchronization (ERD) based neural engagement is monitored and employed for feedback in real-time to ensure the effective execution of MI tasks. Eight healthy subjects and six post-stroke patients were recruited to verify the effectiveness of the system. The results showed that the four-class gesture recognition accuracies of healthy individuals and patients could be improved to 94.37 ± 4.77% and 79.38 ± 6.26%, respectively. Moreover, the designed hybrid BCI could maintain the same degree of neural engagement as observed when subjects solely performed MI tasks. These phenomena demonstrated the interactivity and clinical utility of the developed system for the rehabilitation of hand function in stroke patients.


  • Toward a Fast and Robust MI-BCI: Online Adaptation of Stimulus Paradigm and Classification Model

    by Jiaxing Wang, Weiqun Wang, Jianqiang Su, Yihan Wang, Zeng-Guang Hou

    Motor imagery-based brain–computer interface (MI-BCI) has shown promising potential for improving motor function in neurorehabilitation and motor assistance among patients. However, the decoding accuracy of MI-BCI is limited by the nonstationarity and high intersubject variability of electroencephalogram (EEG) signals. Moreover, decoding MI intention based on fixed-length EEG signals will not only increase the risk of misclassification but also diminish the information transfer rate (ITR) of the BCI system. To overcome these limitations, an adaptive decoding method based on the synchronous adaptation of stimulus paradigm and classification model is proposed to realize a fast and robust MI-BCI. First, an attention-driven dynamic stopping (DS) strategy, which is designed based on the theta-to-beta ratio of EEG signals, is proposed to control the MI-related EEG acquisition time. It can adaptively minimize the data length used for classification under the ensurance of getting a credible classification result, thus improving brain–computer interaction efficiency. Then, the minimum distance to the Riemannian mean algorithm is introduced for the four-class EEG classification. To improve the classification accuracy, the classification model is adapted online based on the error-related potential (Errp) to process the nonstationary characteristics of EEG signals. The feasibility of the proposed online collaborative optimization method in fast and accurate interaction was validated on ten healthy subjects. The results show that the proposed method can significantly improve the EEG classification accuracy by 2.73% with 9.04 ITR improvement compared with that without adaptation (paired t-test, $\bf {p} \mathbf { < } 0.05$ ). Moreover, the MI duration of 2.57 s is recommended for stimulus paradigm design to achieve a better tradeoff between accuracy and efficiency of brain–computer interaction. These phenomena further demonstrate the feasibility of the proposed method in advancing the development of MI-BCI with high efficiency, robustness, and flexibility.


  • Machine learning methods in predicting Down Syndrome

    by Yuqi Yan, Yihan Wang, Yimin Yu

    SPIE Digital Library Proceedings