ATAtsuki Tanaka

Atsuki Tanaka

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Atsuki Tanaka has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Biomechanical Impact of Ramp Lesions and Lateral Meniscal Oblique Radial Tears on Knee Laxity in Anterior Cruciate Ligament–Deficient Knees: A Whole-Limb Cadaveric Study Using an Electromagnetic Measurement System

    by Shin Yoshida, Yuichi Hoshino, Atsuki Tanaka, Yuhei Otsuki, Yuta Nakanishi, Kyohei Nishida, Kanto Nagai, Takehiko Matsushita, Kouki Nagamune, Ryosuke Kuroda

    Background: Ramp lesions and lateral meniscal oblique radial tears (LMORTs) have been suggested to influence knee laxity; however, dynamic changes associated with these lesions remain incompletely understood. Purpose: To quantitatively evaluate changes in knee laxity associated with the sequential addition of a ramp lesion and LMORT in anterior cruciate ligament (ACL)–deficient knees using whole cadaveric lower limbs. Study Design: Controlled laboratory study. Methods: Ten fresh-frozen cadaveric lower limbs were tested under 4 sequential conditions: ACL intact (ACLI), ACL deficient (ACLD), ACLD with a ramp lesion, and ACLD with a ramp lesion and LMORT. Knee laxity was quantitatively assessed with an electromagnetic sensor system. Anterior tibial translation (ATT) was measured during the Lachman test and anterior drawer test at 30°, 60°, and 90° of flexion, as were anterior-posterior tibial translation and posterior tibial acceleration during the pivot-shift test. Comparisons among the 4 conditions were performed by repeated measures analysis of variance, followed by paired t tests with Holm adjustment for multiple comparisons. Results: During the anterior drawer test at 60° of flexion, ATT increased from 7.6 ± 3.7 mm (mean ± SD) in the ACLI group to 9.5 ± 3.3 mm in the ACLD group and 10.5 ± 2.9 mm in the ramp group. ATT was significantly greater in the ramp group than in the ACLI group (mean paired difference, 2.9 mm; 95% CI, 1.7-4.0; P = .002). However, no statistically significant difference was detected between the ACLI and ACLD groups ( P = .064) or between the ACLD and ramp groups ( P = .161). After the addition of LMORT, posterior tibial acceleration during the pivot-shift test increased from 2.0 ± 1.0 to 2.9 ± 0.9 m/s 2 . Conclusion: In this sequential whole-limb model, a concomitant ramp lesion may contribute to anterior laxity at midflexion, while the subsequent addition of LMORT was associated with a further increase in posterior tibial acceleration during the pivot-shift maneuver. Clinical Relevance: These findings highlight the importance of considering concomitant ramp lesions and LMORTs when evaluating knee laxity in ACL-deficient knees.

  • Single‐Bundle ACL Reconstruction With LET or Double‐Bundle ACL Reconstruction may be Considered for High‐Risk Pivot‐Shift Knees: A Cadaveric Biomechanical Study

    by Atsuki Tanaka, Yuichi Hoshino, Shin Yoshida, Yuhei Otsuki, Koji Nukuto, Yuta Nakanishi, Tetsuya Yamamoto, Kyohei Nishida, Kanto Nagai, Noriyuki Kanzaki, et al.

    Lateral extra‐articular tenodesis (LET) has been re‐evaluated, and double‐bundle (DB) anterior cruciate ligament reconstruction (ACLR) has also been used to provide greater rotational stability. The purpose of this study is to quantitatively compare the effects of single‐bundle (SB) ACLR with LET and DB ACLR on knee joint stability in high‐risk pivot‐shift knees. Ten fresh‐frozen cadaveric whole lower limbs were used under five conditions: (A) intact knee, (B) ACL‐deficient knee with meniscal cut, (C) DB ACLR, (D) SB ACLR, and (E) SB ACLR with LET. Anterior tibial translation (ATT) during the Lachman test and posterior tibial acceleration (PTA) during the pivot‐shift test were measured using an electromagnetic measurement system. ATT differed significantly among conditions ( p < 0.01): (A) 6.8 ± 1.8 mm; (B) 13.3 ± 2.1 mm; (C) 7.6 ± 1.5 mm; (D) 8.0 ± 1.0 mm; and (E) 7.7 ± 1.1 mm (mean ± SD). (C), (D), and (E) significantly reduced ATT compared to (B) ( p < 0.01). PTA differed significantly among conditions ( p < 0.01): (A) 1.4 ± 1.2 m/s 2 ; (B) 2.5 ± 1.0 m/s 2 ; (C) 1.3 ± 0.9 m/s 2 ; (D) 1.9 ± 1.2 m/s 2 ; and (E) 1.4 ± 0.7 m/s 2 . (C) and (E) showed significantly improved rotational stability compared to (B) ( p < 0.01 and p < 0.01), whereas (D) did not show a significant difference. SB ACLR alone did not significantly improve rotational stability. In cases with residual pivot‐shift risk, either SB ACLR with LET or DB ACLR may be reasonable surgical options.

  • Open Access

    Three-dimensional finite element analysis for internal fixation of mandibular condylar fractures: a scoping review

    by Yasumasa Kakei, Robert Sader, Philipp Ebener, Atsuki Tanaka, Masaya Akashi, Ryosuke Kuroda, Philipp Thoenissen

    Purpose: Three-dimensional finite element analysis (3D-FEA) has emerged as an essential computational tool for evaluating the biomechanical behaviors of internal fixation systems for mandibular condylar fractures. This scoping review maps and synthesizes the existing literature on 3D-FEA studies investigating the internal fixation of mandibular condylar fractures and explores, in a descriptive manner, differences in methodological focus between European and non-European research centers. Methods: PubMed and Cochrane Library databases were systematically searched following PRISMA-ScR guidelines. Original English-language research articles using 3D-FEA to evaluate internal fixation of mandibular condylar fractures were included. Data were extracted using a standardized charting form. Results: Thirty-six studies met the inclusion criteria. European studies ( n = 12) predominantly focused on development of novel plate designs and mechanical testing protocols, whereas Asian and other nationality studies ( n = 24) emphasized material comparisons between titanium and bioabsorbable systems, patient-specific modeling, and loading condition analysis. Consensus findings include: (1) double-plate fixation provides superior stability; (2) among 3D plate designs, trapezoid plates demonstrate the best performance for subcondylar and condylar base fractures, whereas alpha and lambda plates may be preferable for condylar neck fractures; (3) plate positioning along the posterolateral ramus border and anterolateral sigmoid notch (A+B configuration) offers optimal biomechanical performance; and (4) contralateral molar clenching produces the highest stress concentrations. Conclusion: Across the included FEA studies, the A+B double-plate configuration was the most consistently reported biomechanically favorable approach for both titanium and bioabsorbable systems; the trapezoid plate performed best for subcondylar and condylar base fractures, and two-screw osteosynthesis was effective for condylar head fractures. As these findings derive from computational models, clinical validation remains necessary. Future research should focus on patient-specific modeling, clinical outcome validation, and standardization of methodological protocols.


  • Open Access

    Smoking and lateral hinge fracture are associated with delayed union at 6 months in open wedge distal tibial tuberosity osteotomy

    by Atsuki Tanaka, Ryo Okada, Yuta Nakanishi, Takahiro Yamashita, Shohei Sano, Daisuke Araki

    Purpose: This study aimed to identify risk factors for delayed union 6 months after open wedge distal tibial tuberosity osteotomy (owDTO) using computed tomography (CT) and to evaluate the association between distal flange and posterior cortex union. Methods: This retrospective study was conducted on all patients who underwent owDTO. The exclusion criteria were failure to undergo a 6‐month postoperative follow‐up, absence of CT evaluation, simultaneous anterior cruciate ligament reconstruction, double‐level osteotomy and cases requiring multiple surgical debridements for deep infection. Bone union rates at the flange and posterior cortex were evaluated using CT images obtained 6 months postoperatively. Bone union was determined using zone classification from a previous report. Various factors influencing bone union were examined. Statistical significance was set at p < 0.05. Results: Of the 122 knees reviewed, a total of 79 knees from 77 patients (43 males and 34 females; age, 55 ± 10 years) were analysed after the exclusion of 43 knees. Twenty‐two patients were current smokers. The body mass index was 25.1 ± 3.8 kg/m 2 . Bone union at 6 months was observed in the posterior cortex, distal flange and proximal flange in 55 (69.6%), 67 (84.8%) and 76 (96.2%) knees, respectively. Lateral hinge fracture (LHF) occurred in 20 knees. The posterior cortex union rate was significantly higher in the distal flange union group than in the delayed union group (77.6% vs. 25.0%, p < 0.01). LHF was significantly associated with posterior cortex delayed union ( p = 0.03). Smoking was significantly associated with distal flange delayed union ( p = 0.02). Conclusions: Smoking and LHF were associated with delayed union at 6 months in owDTO. Distal flange union was significantly associated with posterior cortex union. These findings may assist surgeons in identifying patients at risk for delayed union after owDTO and may contribute to improved postoperative management. Level of Evidence: Level IV, retrospective study.

  • Open Access

    Appropriate hinge position to prevent hinge fracture in open wedge distal tuberosity tibial osteotomy

    by Atsuki Tanaka, Daisuke Araki, Takahiro Yamashita, Shohei Sano, Ryo Okada, Mitsuhiko Takahashi, Yasushi Hashimoto

    Purpose: Open wedge distal tuberosity tibial osteotomy (owDTO) is an effective treatment for varus knee osteoarthritis. Hinge fracture is a major complication, and hinge position is a contributing factor. This study aimed to investigate the relationship between hinge position and fractures.Methods: This study examined 42 knees that underwent owDTO. The level of the proximal tibiofibular joint (PTFJ) hinge fracture was investigated on postoperative computed tomography (CT) images measuring the distances and angles around hinge area. Based on previous reports, the hinge position was classified, and hinge fractures were assessed.Results: No cases were found with a hinge position above PTFJ, 41 cases were within PTFJ, and one case was distal to PTFJ. Hinge fractures were observed in 10 patients (23.8%). According to the hinge position classification, seven cases were type I (a fracture within PTFJ), three were type II (a fracture that reaches the distal portion of PTFJ), and no cases were type III (intra‐articular fracture). The anteroposterior hinge width measured perpendicular to the descending cut of the flange on axial CT images at the proximal level of the PTFJ was significantly shorter in the hinge fracture group (p = 0.03).Discussion: The owDTO hinge fracture rate in our study was comparable to that in previous reports on open wedge high tibial osteotomy. As the risk of hinge fracture increases with the shortening of the anterior‐posterior hinge width, our results indicate that preservation of the anterior‐posterior hinge width may help reduce hinge fractures.Level of Evidence: Level III, Retrospective study.


  • Open Access

    Setting hinge position distal to the proximal margin of the distal lateral femur reduces the maximum principal strains of the hinge area and risk of hinge fractures

    by Atsuki Tanaka, Takehiko Matsushita, Tatsuya Nakatsuji, Yosuke Katsui, Kanto Nagai, Kyohei Nishida, Toshiji Mukai, Ryosuke Kuroda

    Purpose: The optimal hinge position to prevent hinge fractures in medial closing wedge distal femoral osteotomy (MCWDFO) based on the biomechanical background has not yet been well examined. This study aimed to examine the appropriate hinge position in MCWDFO using finite element (FE) analysis to prevent hinge fractures.Methods: Computer‐aided design (CAD) models were created using composite replicate femurs. FE models of the MCWDFO with a 5° wedge were created with three different hinge positions: (A) 5 mm proximal to the proximal margin of the lateral epicondylar region, (B) proximal margin level and (C) 5 mm distal to the proximal margin level. The maximum and minimum principal strains in the cortical bone were calculated for each model. To validate the FE analysis, biomechanical tests were performed using composite replicate femurs with the same hinge position models as those in the FE analysis.Results: In the FE analysis, the maximum principal strains were in the order of Models A > B > C. The highest value of maximum principal strain was observed in the area proximal to the hinge. In the biomechanical test, hinge fractures occurred in the area proximal to the hinge in Models A and B, whereas the gap closed completely without hinge fractures in Model C. Fractures occurred in an area similar to where the highest maximal principal strain was observed in the FE analysis.Conclusion: Distal to the proximal margin of the lateral epicondylar region is an appropriate hinge position in MCWDFO to prevent hinge fractures.Level of Evidence: Level V.