Damien Riquet
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Damien Riquet has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Laurent Stubbe
ESO-Paris Recherche, Ecole Supérieure d’Ostéopathie-Paris, 77420 Champs-sur-Marne, France
4 shared publications - Nicolas Houel
PSMS, UR 7507, Université de Reims Champagne-Ardenne, 51097 Reims, France
4 shared publications - Laurent Gaillard
Université de Reims Champagne-Ardenne, PSMS, 51097 Reims, France; Ecole Supérieure d'Ostéopathie - Paris, ESO-Paris Recherche, 77420 Champs-sur-Marne, France
2 shared publications - Caroline Maillot
ESO Paris Rech, Ecole Super Osteopathie, Cite Descartes, F-77420 Champs Sur Marne, France
1 shared publication - Jean Luc Bodnar
ITheMM - Institut de Thermique, Mécanique, Matériaux (Université de Reims Champagne-Ardenne UFR Sciences Exactes et Naturelles Campus du Moulin de la Housse - BP 1039 51687 Reims Cedex 2 FRANCE - France)
1 shared publication - Jean-Luc Bodnar
GRESPI/ECATHERM, UFR Sciences Exactes et Naturelles, BP 1039, 51687 Reims Cedex 02, France
1 shared publication
Latest Publications
- Open Access
Accuracy of the Interpolated Surface Mesh Method for OEP Volume Measurement
Background: Optoelectronic plethysmography (OEP) is a non-invasive technique that can be used to assess both respiratory volumes and chest wall kinematics. An interpolation surface method (ISM) has been recently developed to enhance OEP kinematic analysis. The aim of this study was to test whether ISM is as accurate as the conventional method (CM) for volume measurement when compared with conventional spirometry. Methods: Pneumotachographs and OEP were recorded simultaneously on a healthy subject who performed quiet and deep breathing. Results: In total, 124 tidal volumes (TV) and 50 vital capacities (VC) were obtained. ISM introduced a lower bias for both TV and VC, with narrower limits of agreement for CM in both conditions. Mean discrepancies were systematically Conclusions: ISM and CM have similar volume measurement accuracies. ISM preserves the accuracy of OEP volume measurements and its software environment. Although ISM represents a promising approach for breathing motion analysis, its contribution to improving kinematic analysis remains to be evaluated across a broader range of morphologies and breathing patterns.
Open AccessAccuracy of the Interpolated Surface Mesh Method for OEP Volume Measurement
Background: Optoelectronic plethysmography (OEP) is a non-invasive technique that can be used to assess both respiratory volumes and chest wall kinematics. An interpolation surface method (ISM) has been recently developed to enhance OEP kinematic analysis. The aim of this study was to test whether ISM is as accurate as the conventional method (CM) for volume measurement when compared with conventional spirometry. Methods: Pneumotachographs and OEP were recorded simultaneously on a healthy subject who performed quiet and deep breathing. Results: In total, 124 tidal volumes (TV) and 50 vital capacities (VC) were obtained. ISM introduced a lower bias for both TV and VC, with narrower limits of agreement for CM in both conditions. Mean discrepancies were systematically Conclusions: ISM and CM have similar volume measurement accuracies. ISM preserves the accuracy of OEP volume measurements and its software environment. Although ISM represents a promising approach for breathing motion analysis, its contribution to improving kinematic analysis remains to be evaluated across a broader range of morphologies and breathing patterns.
- Open Access
- 29 August 2025
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 74
Influence of infrared camera resolution and operator reproducibility in the assessment of skin temperature of the hands
- 29 August 2025
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 74
Open AccessInfluence of infrared camera resolution and operator reproducibility in the assessment of skin temperature of the hands
- Open Access
- 8 May 2025
- Published by Elsevier in Journal of Bodywork and Movement Therapies
- Vol. 43, 293-299
Osteopathic manipulative treatment in a patient with idiopathic scoliosis assessed by breathing pattern characterization using optoelectronic plethysmography and quality of life — a case report
- 8 May 2025
- Published by Elsevier in Journal of Bodywork and Movement Therapies
- Vol. 43, 293-299
Open AccessOsteopathic manipulative treatment in a patient with idiopathic scoliosis assessed by breathing pattern characterization using optoelectronic plethysmography and quality of life — a case report
- Open Access
- 16 March 2024
- Published by Elsevier in Journal of Bodywork and Movement Therapies
- Vol. 39, 447-453
Post-operative osteopathic manipulative treatment of Morel-Lavallee syndrome assessed using infrared thermal imaging: A case report
- 16 March 2024
- Published by Elsevier in Journal of Bodywork and Movement Therapies
- Vol. 39, 447-453
Open AccessPost-operative osteopathic manipulative treatment of Morel-Lavallee syndrome assessed using infrared thermal imaging: A case report