ASAndré Sprengers

André Sprengers

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


André Sprengers has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Bangyu Lan

    Robotics and Mechatronics group in the Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, Enschede, Netherlands

    1 shared publication
  • Jasper Homminga

    Department of Biomechanical Engineering, University of Twente, 7521 HK Enschede, The Netherlands

    1 shared publication
  • Kenan Niu

    Robotics and Mechatronics group, Faculty of Electrical Engineering, Mathematics and Computer Science, University of Twente, Enschede, The Netherlands

    1 shared publication
  • Nico Verdonschot

    Radboud University Medical Centre, Radboud Institute for Health Sciences, Orthopaedic Research Laboratory, Nijmegen, the Netherlands; University of Twente, Faculty of Engineering Technology, Laboratory for Biomechanical Engineering, Enschede, the Netherlands

    1 shared publication
  • Victor Sluiter

    Department of Biomechanical Engineering, University of Twente, Enschede, NB, The Netherlands

    1 shared publication

Latest Publications

  • Open Access

    A Method to Track 3D Knee Kinematics by Multi-Channel 3D-Tracked A-Mode Ultrasound

    by Kenan Niu, Victor Sluiter, Bangyu Lan, Jasper Homminga, André Sprengers, Nico Verdonschot

    This paper introduces a method for measuring 3D tibiofemoral kinematics using a multi-channel A-mode ultrasound system under dynamic conditions. The proposed system consists of a multi-channel A-mode ultrasound system integrated with a conventional motion capture system (i.e., optical tracking system). This approach allows for the non-invasive and non-radiative quantification of the tibiofemoral joint’s six degrees of freedom (DOF). We demonstrated the feasibility and accuracy of this method in the cadaveric experiment. The knee joint’s motions were mimicked by manually manipulating the leg through multiple motion cycles from flexion to extension. To measure it, six custom ultrasound holders, equipped with a total of 30 A-mode ultrasound transducers and 18 optical markers, were mounted on various anatomical regions of the lower extremity of the specimen. During experiments, 3D-tracked intra-cortical bone pins were inserted into the femur and tibia to measure the ground truth of tibiofemoral kinematics. The results were compared with the tibiofemoral kinematics derived from the proposed ultrasound system. The results showed an average rotational error of 1.51 ± 1.13° and a translational error of 3.14 ± 1.72 mm for the ultrasound-derived kinematics, compared to the ground truth. In conclusion, this multi-channel A-mode ultrasound system demonstrated a great potential of effectively measuring tibiofemoral kinematics during dynamic motions. Its improved accuracy, nature of non-invasiveness, and lack of radiation exposure make this method a promising alternative to incorporate into gait analysis and prosthetic kinematic measurements later.