Shiv Chopra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shiv Chopra has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Holek
Queen Elizabeth Jubilee Hospital Brisbane Australia
1 shared publication Damian Ryan
MBBS, FRACS (Orth); Hand Surgery Clinic, Sydney Hospital, Sydney, New South Wales, AUSTRALIA
1 shared publication- Elias Moisidis
MBBS FRACS; Department of Plastic Surgery, St Vincent’s Hospital Sydney, Darlinghurst, New South Wales, AUSTRALIA
1 shared publication Frederick K Clarke
FRACS; St Vincent’s Hospital, Plastic and Reconstructive Surgery, Sydney, New South Wales, Australia
1 shared publicationGillian Farrell
International Collaboration of Breast Registry Activities (ICOBRA) The Royal Marsden Hospital Chelsea London UNITED KINGDOM
1 shared publicationGwenda Chapman
Herston Biofabrication Institute Brisbane Australia
1 shared publication
Latest Publications
- 30 August 2026
- Published by Wiley in Anz Journal of Surgery
Validation of a Three‐Dimensional Handheld Scanner in Measuring Breast Anthropometrics
Background: Outcomes in aesthetic breast surgery are dependent on accurate pre‐operative breast measurements. The accuracy of large scale 3‐dimentional scanners has been reported, the use of handheld scanners has not been described. Objectives: The authors aimed to determine the trueness of anthropometric measurements of breasts obtained from a handheld 3D scan compared to direct measurements. Methods: Three raters measured the breasts of 19 women using three anthropometric measurements (direct) measurements: sternal notch to nipple (Sn‐N), nipple to inframammary fold (N‐IMF), base width (BW). The measurements were taken directly by two raters using a measuring tape, and digitally by one rater using the software on 3D scans acquired with the Artec Leo handheld 3D scanner. Statistical analysis was completed with Bland–Altman plots as well as scatter plots to identify bias between the two methods. Results: The study found that the 3D scanner showed varying levels of bias when compared to direct breast measurements. Sn‐N measurement showed smaller differences, while the N‐IMF and BW measurements exhibited larger discrepancies. The 3D scanning process was significantly faster, taking only 30 s per scan, compared to roughly 5 min for direct measurements, with an additional 10 min for image processing and digital measurements. Conclusion: Three‐dimensional scanning is most accurate for Sn‐N and is more variable when measuring BW and N‐IMF due to obscured landmarks on frontal imaging. The BW and N‐IMF measurements also showed the most inter‐rater variability. Consistent with previous research 3D scanning has limited trueness when measuring N‐IMF as it is a dynamic measurement.
- 30 August 2026
- Published by Wiley in Anz Journal of Surgery
Validation of a Three‐Dimensional Handheld Scanner in Measuring Breast Anthropometrics
Background: Outcomes in aesthetic breast surgery are dependent on accurate pre‐operative breast measurements. The accuracy of large scale 3‐dimentional scanners has been reported, the use of handheld scanners has not been described. Objectives: The authors aimed to determine the trueness of anthropometric measurements of breasts obtained from a handheld 3D scan compared to direct measurements. Methods: Three raters measured the breasts of 19 women using three anthropometric measurements (direct) measurements: sternal notch to nipple (Sn‐N), nipple to inframammary fold (N‐IMF), base width (BW). The measurements were taken directly by two raters using a measuring tape, and digitally by one rater using the software on 3D scans acquired with the Artec Leo handheld 3D scanner. Statistical analysis was completed with Bland–Altman plots as well as scatter plots to identify bias between the two methods. Results: The study found that the 3D scanner showed varying levels of bias when compared to direct breast measurements. Sn‐N measurement showed smaller differences, while the N‐IMF and BW measurements exhibited larger discrepancies. The 3D scanning process was significantly faster, taking only 30 s per scan, compared to roughly 5 min for direct measurements, with an additional 10 min for image processing and digital measurements. Conclusion: Three‐dimensional scanning is most accurate for Sn‐N and is more variable when measuring BW and N‐IMF due to obscured landmarks on frontal imaging. The BW and N‐IMF measurements also showed the most inter‐rater variability. Consistent with previous research 3D scanning has limited trueness when measuring N‐IMF as it is a dynamic measurement.
- Open Access
- 9 April 2024
- Published by Australian Society of Plastic Surgeons in Australasian Journal of Plastic Surgery
- Vol. 7 (1) , 1-6
History of the Australian Breast Device Registry
Following the Dow Corning crisis in the 1990s, several national breast implant registries were formed by plastic surgery societies around the world. The Australian Breast Implant Registry (BIR) was developed in 1997 as a voluntary registry where patients were charged a moiety per implant. At the time of the Poly Implant Prothèse (PIP) crisis in 2010, there were over 30,000 registrations in the BIR. However, when the dataset was interrogated to retrieve PIP implant-related information, only 3.4 per cent of 13,000 PIP implants were recorded in the BIR database.
- 9 April 2024
- Published by Australian Society of Plastic Surgeons in Australasian Journal of Plastic Surgery
- Vol. 7 (1) , 1-6
Open AccessHistory of the Australian Breast Device Registry
Following the Dow Corning crisis in the 1990s, several national breast implant registries were formed by plastic surgery societies around the world. The Australian Breast Implant Registry (BIR) was developed in 1997 as a voluntary registry where patients were charged a moiety per implant. At the time of the Poly Implant Prothèse (PIP) crisis in 2010, there were over 30,000 registrations in the BIR. However, when the dataset was interrogated to retrieve PIP implant-related information, only 3.4 per cent of 13,000 PIP implants were recorded in the BIR database.
- Open Access
- 29 September 2022
- Published by Australian Society of Plastic Surgeons in Australasian Journal of Plastic Surgery
- Vol. 5 (2) , 37-43
Smartphone goniometer for reliable and convenient measurement of finger range of motion: a comparative study
**Objective**: Goniometer measurements are commonly used in hand clinics to follow progress or as an outcome measure for acute and chronic conditions. The use of a smartphone goniometer application may provide a practical alternative for clinicians. This study sought to assess accuracy in range-of-motion measurements obtained by a smartphone goniometer application compared to a traditional universal goniometer in healthy and diseased hands.**Methods**: Patients with various hand disease processes were recruited through a tertiary hospital hand clinic, as well as healthy volunteers. Middle and little fingers were assessed at the metacarpophalangeal (MCP), proximal interphalangeal (PIP) and distal interphalangeal (DIP) joints for flexion and extension. Measurements were taken using a universal goniometer and an iPhone® smartphone goniometer application by two independent evaluators using a standardised proforma.**Results**: Twenty patients were recruited (50% male; 13 healthy volunteers and seven with hand pathology). There were no significant differences in measurements using the smartphone goniometer. The only significant difference found using the universal goniometer was for little finger PIP joint flexion; however, the difference was only 2.5°. Comparison of the average measurements using universal and smartphone goniometers found significant differences for six joints, with none of these >5° (largest 4.6°).**Conclusion**: The goniometer iPhone® application is as reliable as traditional goniometry techniques and would be a practical tool for everyday use in hand clinics. Its uptake may provide broader utility for patient self-measurement and telemedicine.
- 29 September 2022
- Published by Australian Society of Plastic Surgeons in Australasian Journal of Plastic Surgery
- Vol. 5 (2) , 37-43
Open AccessSmartphone goniometer for reliable and convenient measurement of finger range of motion: a comparative study
**Objective**: Goniometer measurements are commonly used in hand clinics to follow progress or as an outcome measure for acute and chronic conditions. The use of a smartphone goniometer application may provide a practical alternative for clinicians. This study sought to assess accuracy in range-of-motion measurements obtained by a smartphone goniometer application compared to a traditional universal goniometer in healthy and diseased hands.**Methods**: Patients with various hand disease processes were recruited through a tertiary hospital hand clinic, as well as healthy volunteers. Middle and little fingers were assessed at the metacarpophalangeal (MCP), proximal interphalangeal (PIP) and distal interphalangeal (DIP) joints for flexion and extension. Measurements were taken using a universal goniometer and an iPhone® smartphone goniometer application by two independent evaluators using a standardised proforma.**Results**: Twenty patients were recruited (50% male; 13 healthy volunteers and seven with hand pathology). There were no significant differences in measurements using the smartphone goniometer. The only significant difference found using the universal goniometer was for little finger PIP joint flexion; however, the difference was only 2.5°. Comparison of the average measurements using universal and smartphone goniometers found significant differences for six joints, with none of these >5° (largest 4.6°).**Conclusion**: The goniometer iPhone® application is as reliable as traditional goniometry techniques and would be a practical tool for everyday use in hand clinics. Its uptake may provide broader utility for patient self-measurement and telemedicine.
- Open Access
- 1 March 2018
- Published by Australian Society of Plastic Surgeons in Australasian Journal of Plastic Surgery
- Vol. 1 (1) , 79-85
A comparison of maxillofacial trauma before and after implementation of lockout laws in Sydney
Background: Lockout reforms were introduced in February 2014 by the New South Wales government in an attempt to curb alcohol-related violence in Sydney, following a number of fatalities. Changes include 1.30 am venue lockouts and the 3 am cessation of alcohol service. This study aims to assess the results of these reforms through analysis of departmental treatment data. All maxillofacial fractures that required operative management at St Vincent’s Hospital, Sydney, over a two-year period pre- and post reforms were analysed. Methods: Medical information, from multiple sources, of patients that required operative management for maxillofacial fractures over a two-year period (2012–2014) were compared to those between (2014–2016). Data collected included age, gender, demographics, mechanism of injury, pattern of injury, treatment required, association with alcohol, time and place of injury, and long-term complications. Results: One hundred and forty-five maxillofacial fractures were operatively treated prior to the reforms compared to only 58 (_p_ < 0.001) post. Reported incidents occurring in the city significantly fell from 54 to 15 (_p_ < 0.001), with no change in peripheral locations. The operated cases associated with alcohol dropped post reforms—102/145 (70%) versus 33/58 (57%). The number of assaults related to ‘king hits’ significantly reduced from 30 (33%) to just 5 (19.2%). Conclusion: This study demonstrates a clear correlation with the reduction in maxillofacial trauma, alcohol and violence in a localised region of Sydney since the arrival of the lockout reforms. As such, it can provide guidance to other regions in Australia into the effects of such laws and its repercussions on patient care and service.
- 1 March 2018
- Published by Australian Society of Plastic Surgeons in Australasian Journal of Plastic Surgery
- Vol. 1 (1) , 79-85
Open AccessA comparison of maxillofacial trauma before and after implementation of lockout laws in Sydney
Background: Lockout reforms were introduced in February 2014 by the New South Wales government in an attempt to curb alcohol-related violence in Sydney, following a number of fatalities. Changes include 1.30 am venue lockouts and the 3 am cessation of alcohol service. This study aims to assess the results of these reforms through analysis of departmental treatment data. All maxillofacial fractures that required operative management at St Vincent’s Hospital, Sydney, over a two-year period pre- and post reforms were analysed. Methods: Medical information, from multiple sources, of patients that required operative management for maxillofacial fractures over a two-year period (2012–2014) were compared to those between (2014–2016). Data collected included age, gender, demographics, mechanism of injury, pattern of injury, treatment required, association with alcohol, time and place of injury, and long-term complications. Results: One hundred and forty-five maxillofacial fractures were operatively treated prior to the reforms compared to only 58 (_p_ < 0.001) post. Reported incidents occurring in the city significantly fell from 54 to 15 (_p_ < 0.001), with no change in peripheral locations. The operated cases associated with alcohol dropped post reforms—102/145 (70%) versus 33/58 (57%). The number of assaults related to ‘king hits’ significantly reduced from 30 (33%) to just 5 (19.2%). Conclusion: This study demonstrates a clear correlation with the reduction in maxillofacial trauma, alcohol and violence in a localised region of Sydney since the arrival of the lockout reforms. As such, it can provide guidance to other regions in Australia into the effects of such laws and its repercussions on patient care and service.