Yu-Xia Dong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yu-Xia Dong has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Xiao Li
School of Civil and Environmental Engineering, Harbin Institute of Technology, Shenzhen 518055, People’s Republic of China
2 shared publications - Feng-Liang Zhang
School of Intelligent Civil and Ocean Engineering, Harbin Institute of Technology, Shenzhen 518055, China
1 shared publication Wei Xiang
Technical Center, Shenzhen Road & Bridge Group, Shenzhen 518055, People’s Republic of China
1 shared publication
Latest Publications
- 2 September 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (11) , 115117
Developing a BIM based digital twin system for structural health monitoring of civil infrastructure
The utilization of building information modeling (BIM) within digital technology facilitates the creation of three-dimensional representations for monitoring data in large-scale civil infrastructure. In response to the need for intelligent structural management, this study establishes a structural health monitoring (SHM) system and foundational framework based on digital twins. This framework integrates information from various sources and facilitates collaborative efforts for structural operation and maintenance. Additionally, the SHM system integrates actual monitoring measurements and early warning mechanisms to consolidate multi-source monitoring data with BIM. Through real-time analysis, the system provides insights into the operational status of bridges, capturing geometric, physical, and performance evolution characteristics. To construct the system, engineering challenges are initially digitized, with appropriate sensors deployed on real bridge structures to monitor dynamic (acceleration) and static (strain, displacement) physical information during bridge operation. Subsequently, through wireless communication and data storage technologies, the monitored physical data serves as input for mode identification and early warning algorithms, facilitating the acquisition of structural performance information. Finally, three-dimensional display technology enables real-time calculation and rendering of BIM models, fostering the exchange and interaction of monitoring and BIM information, thus enhancing the intelligence of SHM system.
- 2 September 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (11) , 115117
Developing a BIM based digital twin system for structural health monitoring of civil infrastructure
The utilization of building information modeling (BIM) within digital technology facilitates the creation of three-dimensional representations for monitoring data in large-scale civil infrastructure. In response to the need for intelligent structural management, this study establishes a structural health monitoring (SHM) system and foundational framework based on digital twins. This framework integrates information from various sources and facilitates collaborative efforts for structural operation and maintenance. Additionally, the SHM system integrates actual monitoring measurements and early warning mechanisms to consolidate multi-source monitoring data with BIM. Through real-time analysis, the system provides insights into the operational status of bridges, capturing geometric, physical, and performance evolution characteristics. To construct the system, engineering challenges are initially digitized, with appropriate sensors deployed on real bridge structures to monitor dynamic (acceleration) and static (strain, displacement) physical information during bridge operation. Subsequently, through wireless communication and data storage technologies, the monitored physical data serves as input for mode identification and early warning algorithms, facilitating the acquisition of structural performance information. Finally, three-dimensional display technology enables real-time calculation and rendering of BIM models, fostering the exchange and interaction of monitoring and BIM information, thus enhancing the intelligence of SHM system.
- 15 April 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (7) , 076206
Fully automated operational modal identification based on scale-space peak picking algorithm and power spectral density estimation
Modal analysis is a fundamental and essential research direction in the field of structural engineering. The ultimate goal is to determine the modal parameters of the structures. However, the existing modal analysis algorithms often require a large number of parameter adjustments and manual intervention during operation, which cannot be fully automated. In order to realize the automatic identification of modal parameters, the automatic operational modal identification method (AOMI) is proposed based on the interpolated power spectral density estimation (IPSE). To achieve more precise spectrum analysis in the low-frequency band, IPSE is employed to perform Fourier transform on the original frequency domain segment with optimized frequency resolution. This enhances the sharpness of the obtained spectrum in the low-frequency range, making peak frequencies more discernible. Subsequently, the scale-space peak picking algorithm is used to automatically obtain the peak of the power spectral density (PSD), thus enabling the automatic identification of the natural frequency. Finally, the frequency domain decomposition method (FDD) is used to identify modal parameters based on the natural frequencies. The effectiveness of AOMI is verified through the modal identification of the old steel truss bridge and the three layer framework. Under the environmental excitation, the frequencies identified by the IPSE method is close to that of FDD, Bayesian fast fourier transform (FFT) and covariance driven stochastic subspace identification (SSI-COV). Furthermore, the PSD obtained through IPSE has sharper peak than that of FDD and the Welch’s method. The damping ratio identification accuracy and modal assurance criterion (MAC) are satisfactory in AOMI, which can improve the automatic performance.
- 15 April 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (7) , 076206
Fully automated operational modal identification based on scale-space peak picking algorithm and power spectral density estimation
Modal analysis is a fundamental and essential research direction in the field of structural engineering. The ultimate goal is to determine the modal parameters of the structures. However, the existing modal analysis algorithms often require a large number of parameter adjustments and manual intervention during operation, which cannot be fully automated. In order to realize the automatic identification of modal parameters, the automatic operational modal identification method (AOMI) is proposed based on the interpolated power spectral density estimation (IPSE). To achieve more precise spectrum analysis in the low-frequency band, IPSE is employed to perform Fourier transform on the original frequency domain segment with optimized frequency resolution. This enhances the sharpness of the obtained spectrum in the low-frequency range, making peak frequencies more discernible. Subsequently, the scale-space peak picking algorithm is used to automatically obtain the peak of the power spectral density (PSD), thus enabling the automatic identification of the natural frequency. Finally, the frequency domain decomposition method (FDD) is used to identify modal parameters based on the natural frequencies. The effectiveness of AOMI is verified through the modal identification of the old steel truss bridge and the three layer framework. Under the environmental excitation, the frequencies identified by the IPSE method is close to that of FDD, Bayesian fast fourier transform (FFT) and covariance driven stochastic subspace identification (SSI-COV). Furthermore, the PSD obtained through IPSE has sharper peak than that of FDD and the Welch’s method. The damping ratio identification accuracy and modal assurance criterion (MAC) are satisfactory in AOMI, which can improve the automatic performance.