DLDunfa Long

Dunfa Long

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dunfa Long has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Chaoyang Shi

    School of Mechanical Engineering Key Laboratory of Mechanism Theory and Equipment Design of Ministry of Education Tianjin University Tianjin China

    7 shared publications
  • Shaoan Chen

    Key Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, School of Mechanical Engineering, Tianjin University, Tianjin, China

    4 shared publications
  • Chengzhi Hu

    Shenzhen Key Laboratory of Biomimetic Robotics and Intelligent Systems, Department of Mechanical and Energy Engineering, Southern University of Science and Technology, Shenzhen, China

    2 shared publications
  • Feiyang Chen

    Tianjin University

    2 shared publications
  • Kaifeng Wang

    Key Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, Tianjin University, Tianjin 300354, China

    2 shared publications
  • Zengsheng Li

    Key Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, School of Mechanical Engineering, Tianjin University, Tianjin, China

    2 shared publications

Latest Publications

  • Development of a Novel 7-DOF Position-Orientation Decoupled Microsurgical Robot with Motorized Instruments for Microvascular Anastomosis

    by Dunfa Long, Shaoan Chen, Shuai Ao, Zhiqiang Zhang, Chengzhi Hu, Chaoyang Shi

    This work introduces a novel compact 7-degree-of-freedom (7-DOF) microsurgical robot with position-orientation decoupling capacity for microvascular anastomosis. The proposed system employs a modular architecture combining a proximal displacement platform for 3D small-stroke translation and a distal compact remote center of motion (RCM) mechanism for wide-range orientation adjustment. This design meets the workspace requirements for microvascular anastomosis, requiring extensive orientation adjustments with minimal positional movement and reducing the system footprint. The parasitic motion reverse self-compensation method has been developed for motorized surgical instruments, effectively reducing operational resistance to improve precision. Theoretical analysis has been performed on both the RCM mechanism and motorized surgical instruments, and kinematics-based parameter optimization and data-driven calibration have been conducted to enhance superior performance. A prototype has been constructed, and its experimental validation demonstrated that the system achieved repeatability of 11.24 ± 2.31 μm (XY) and 12.46 ± 4.48 μm (YZ), and absolute positioning accuracy of 29.80 ± 12.27 μm (XY) and 37.02 ± 19.47 μm (YZ), meeting super-microsurgical requirements. Experiments that include needle-threading and stamen peeling tasks demonstrate the robot's superior dexterity and manipulation capabilities.


  • Design and Performance Investigation of the Microanastomosis Surgical Robot Based on the Novel Dual-Triangular RCM Mechanism

    by Shaoan Chen, Dunfa Long, Kaifeng Wang, Zhengbao Yang, Bo Zhang, Chaoyang Shi

    The manual microanastomosis poses significant challenges for surgeons who face inherent limitations in terms of physiological tremor and dexterity constraints. It requires precise repair and reconstruction of small-caliber tissues (0.3-3mm), including vessels, nerves, and lymphatic structures. This study presents a specialized robotic system for microanastomosis based on a 7-degree-of-freedom (DOF) position-orientation decoupled configuration. The system integrates a 3-DOF linear stage for positioning with a novel 3-DOF dual-triangular remote center of motion (RCM) mechanism for orientation control, and a 1-DOF two-finger mimicking end-effector is incorporated to facilitate rapid interchange and precise actuation of different microsurgical instruments. Positioning accuracy was improved through kinematic parameters calibration and RCM point deviation compensation using the linear stage. Experimental results validate the prototype performance in the X-Z plane and Y-Z plane, demonstrating repeatability of 1216μm and 1217μm, respectively, and absolute positioning accuracy of 56115μm and 83135μm. In master-slave control mode, motion accuracy ranges from 14-25μm with a motion scaling ratio between 5x and 20x. Additionally, needle threading and stamen stripping experiments were conducted to validate the robot’s feasibility for microanastomosis surgery.


  • Achieving High Rotary Motion Consistency Based on the Novel Internal-Gear-Mechanism-Inspired Rolling Driving Principle (RDP) With a Single PZT

    by Dunfa Long, Fujun Wang, Shaoan Chen, Chengzhi Hu, Chaoyang Shi

    The rotary stick-slip actuators typically employ the asymmetric driving principle to achieve stick-slip motion, resulting in an inconsistent bidirectional driving process and posing challenges for achieving high rotary motion consistency with a single PZT. The current approaches involve multiple sets of driving structures to achieve high consistency but bring a complex system with multi-PZTs and need complex adjustment procedures for symmetrical assembly. This work presents a novel rolling driving principle (RDP) to ensure an identical bidirectional driving process and achieve single-PZT actuated high rotary motion consistency, owing to the RDP’s symmetrical circular structure and tangential contact condition. Moreover, its tangential contact condition enhances the adaptive capability to the assembly errors. An RDP-type rotary stick-slip actuator is proposed based on the newly designed isosceles trapezoidal flexible mechanism (ITFM). The axial drift of the ITFM flexure is modeled and the design optimization is conducted to determine the ITFM’s optimal structural parameters. Experiments have been carried out to verify the prototyped actuator’s performance at both high and low frequencies. The results demonstrate the RDP-type actuator’s excellent bidirectional motion consistency, with speed difference ratios of 1.47% at 10 Hz and 7.57% at 320 Hz, and angular resolution differences of 2.06% (0.97 μrad and 0.95 μrad) for a 20 mm rotor diameter.


  • A Posterior Segment Ocular Microsurgical Robot With a Decoupling RCM Mechanism Based on a Minimized Internal Constraint Force Optimization Method

    by Zhi Li, Dunfa Long, Feiyang Chen, Kaifeng Wang, Chaoyang Shi

    This paper presents a leader-follower robotic system featuring a novel 4-degree-of-freedom (4-DOF) Remote Center of Motion (RCM) mechanism, tailored to address the limitations associated with traditional posterior segment ocular microsurgery. The proposed 4-DOF mechanism employs parallelogram motion replication to relocate the bulky instrument insertion drive from the end-effector to the proximal linkage on the base, minimizing obstruction to the microscope’s field of view and the surgical environment. The mechanism’s orthogonal or coincident arranged degrees of freedom, paired with independent drive units, facilitate calibration and enhance control accuracy. A minimized internal constraint force optimization method was proposed to improve RCM point stability and tip positioning accuracy. The mechanism’s configuration and parameters were optimized through an analytical mechanics model, effectively reducing the constraint force on the internal components under the same external loads, thereby minimizing deformation and maintaining accuracy. To enhance robot compatibility, modular surgical instruments with a quick-change coupler were developed based on the analysis of traditional instruments’ characteristics. The prototype was built and kinematically calibrated to reduce manufacturing and assembly errors and thus improve accuracy. Following kinematic calibration to minimize manufacturing and assembly errors, experimental validation revealed positioning accuracies of 49 ± 23 μ m and 22 ± 13 μ m, repeatabilities of 25 ± 10 μ m and 9 ± 4 μ m, and RCM deviations of 13 ± 10 μ m and 18 ± 11 μ m on the X-Z and Y-Z planes, respectively. The cannulation experiment further demonstrates the prototype’s potential for robot-assisted vitreoretinal microsurgery.


  • Open Access

    An Automated Pick-and-Place Method for Irregular-Shaped Microspheres Inspired by Chopstick Operation

    by Zengsheng Li, Dunfa Long, Shaoan Chen, Chaoyang Shi

    This paper proposes an automated irregular-shaped microbead assembly method inspired by the manipulation way of chopsticks that includes a lifting pickup strategy inspired by Tangyuan ingestion and an adhesion-vibration release strategy emulating the dumpling plating. Drawing inspiration from the Tangyuan moving process with chopsticks, the lifting strategy picks up the microbeads at a relatively lower position, thus minimizing damage to assembled micro-objects and enhancing the success rate of picking up irregularly shaped microbeads. The adhesion-vibration strategy utilizes the adhesion force between the substrate and the microspheres as well as the inertia of the microbeads to mitigate the rolling phenomenon and achieve precise release for irregular microbeads. Subsequently, a modular direct-description-method-based feed-forward model is developed to control the opening and closing of the tips accurately. Finally, the above-mentioned elements are integrated with visual recognition and position control techniques to establish an automated microbead assembly method. The developed method exhibits a high pickup success rate and high accuracy release of irregular microbeads validated through pick-and-place experiments and eventually applies to both 2D and 3D assemblies. The results indicate that the proposed method achieves a final pickup success rate of 95% for irregular microbeads, with a maximum release error of 9.34 μm and an average error of 7.62 μm at release. These release errors are equivalent to 4.67% and 3.81% of the average diameter of the assembled microbeads, respectively.


  • A Modular Direct Description Method With Low Memory Usage and Execution Time for Hysteresis Modeling and Compensation of Piezoelectric Actuators

    by Zengsheng Li, Xinjian Fan, Dunfa Long, Zhan Yang, Chaoyang Shi

    This paper proposes a modular direct description method based on the relatively weak interdependence among hysteresis properties to establish a hysteresis model that includes the major curves fitter (MaCF) module, the turning points recorder (TPR) module, and the minor curves fitter (MiCF) module. The MaCF module utilizes the Fourier series fitting method to fit the major hysteresis curves, improving model scalability in conjunction with the modular approach. The TPR module is established to manage the turning points. A memory optimization strategy is further proposed to optimize the model in terms of memory consumption and execution time. The MiCF module then employs a two-stage curve fitting strategy to fit the minor hysteresis curves accurately. Finally, three modules are cascaded to construct the hysteresis model. Experiments have been performed to validate the excellent performance of the developed model in terms of model accuracy, memory usage, and execution time. The results indicate that the model only needs 0.28 KB of memory space to achieve accurate prediction and compensation of hysteresis phenomenon, the standardized normalized maximum error ( $NME)$ of hysteresis curve prediction is about 1%, and the $NME$ value of compensation error is 1.37%. Meanwhile, the average execution time of the model is less than 1 $\mu $ s with a variance of 0.04. Note to Practitioners —The presented modular direct description (MDD) method can accurately describe and compensate hysteresis phenomenon. The MDD-based model offers the advantage of small memory consumption, making it suitable for application in memory-constrained scenarios, such as offline deployment of microcontrollers and embedded systems. Meanwhile, the execution time of this model is short and stable, which can be applied in applications requiring a high computational period, such as the precise position control of stick-slip drive motors, the precise speed control of ultrasonic motors, and other scenarios with the presence of high-frequency inputs. The MDD method has the potential to become a general modeling method for solving hysteresis challenges, and can be used by simply modifying the relevant modules according to the hysteresis rules in different domains, such as in the fields of artificial muscles and shape memory alloys.