Hongrae Im
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hongrae Im has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Am Jang
Sungkyunkwan University
15 shared publications - Duc Anh Nguyen
Department of Global Smart City, Sungkyunkwan University (SKKU), 2066, Seobu-ro, Jangan-gu, Suwon-si, Gyeonggi-do, 16419, Republic of Korea
4 shared publications Alicia Kyoungjin An
3 shared publicationsDong-Gun Jun
3 shared publicationsTaehun Kim
3 shared publications- Yujae Jeon
Sungkyunkwan University
3 shared publications
Latest Publications
- Open Access
- 11 June 2026
- Published by Elsevier in SSRN Electronic Journal
Hybrid Siloxane-Modified Membrane Contactors for Long-Term Stable CO2 Capture from CH4/CO2 Mixtures under Alkaline Absorption Conditions
Biogas generated from the anaerobic digestion of organic waste is a key renewable source. However, the efficient separation and mineralization of carbon dioxide (CO2) remain a critical challenge for producing high-purity methane (CH4) and achieving carbon neutrality. Membrane contactor processes are promising for selective CH4/CO2 separation, but their practical application is often hindered by membrane wetting from alkaline absorbents, which severely deteriorates selectivity and permeation flux. In this study, a robust superhydrophobic layer was employed on a polyvinylidene fluoride (PVDF) substrate using a polydimethylsiloxane (PDMS) and polyhedral oligomeric silsesquioxane (POSS) composite to address wetting limitations. Results revealed that coating with 7 wt% PDMS and a PDMS/POSS composite (7/5 wt%) increased the water contact angle from 108.08° ± 5.93° (virgin PVDF) to 147.82° ± 3.98° and 157.68° ± 2.37°, respectively. Stability tests over 10 cycles demonstrated the superior alkaline durability of the PDMS/POSS-coated membrane, which retained 89.72 ± 7.63% of its initial flux, compared with 45.16 ± 5.24% and 64.18 ± 7.94% for the virgin PVDF and PDMS-coated membranes, respectively. For the most robust P3 membrane, 554.02 ± 4.81 mg/L of CO2 was captured in the stripping solution within 1 h, with no detectable CH4 crossover. The captured CO2 was successfully mineralized into potassium carbonate via ethanol-induced phase separation, as confirmed by Fourier-transform infrared spectroscopy and X-ray diffraction. These results demonstrate that the superhydrophobic durability of the PDMS/POSS-coated membrane provides a viable pathway for stable and long-term CH4/CO2 separation.
- 11 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessHybrid Siloxane-Modified Membrane Contactors for Long-Term Stable CO2 Capture from CH4/CO2 Mixtures under Alkaline Absorption Conditions
Biogas generated from the anaerobic digestion of organic waste is a key renewable source. However, the efficient separation and mineralization of carbon dioxide (CO2) remain a critical challenge for producing high-purity methane (CH4) and achieving carbon neutrality. Membrane contactor processes are promising for selective CH4/CO2 separation, but their practical application is often hindered by membrane wetting from alkaline absorbents, which severely deteriorates selectivity and permeation flux. In this study, a robust superhydrophobic layer was employed on a polyvinylidene fluoride (PVDF) substrate using a polydimethylsiloxane (PDMS) and polyhedral oligomeric silsesquioxane (POSS) composite to address wetting limitations. Results revealed that coating with 7 wt% PDMS and a PDMS/POSS composite (7/5 wt%) increased the water contact angle from 108.08° ± 5.93° (virgin PVDF) to 147.82° ± 3.98° and 157.68° ± 2.37°, respectively. Stability tests over 10 cycles demonstrated the superior alkaline durability of the PDMS/POSS-coated membrane, which retained 89.72 ± 7.63% of its initial flux, compared with 45.16 ± 5.24% and 64.18 ± 7.94% for the virgin PVDF and PDMS-coated membranes, respectively. For the most robust P3 membrane, 554.02 ± 4.81 mg/L of CO2 was captured in the stripping solution within 1 h, with no detectable CH4 crossover. The captured CO2 was successfully mineralized into potassium carbonate via ethanol-induced phase separation, as confirmed by Fourier-transform infrared spectroscopy and X-ray diffraction. These results demonstrate that the superhydrophobic durability of the PDMS/POSS-coated membrane provides a viable pathway for stable and long-term CH4/CO2 separation.
- Open Access
- 16 April 2026
- Published by Elsevier in SSRN Electronic Journal
Constrained Bayesian Updating Based on Posterior Predictive Checks for Reverse Osmosis Membrane Maintenance in Wastewater Treatment
Reliable prediction of remaining useful life (RUL) is crucial for the predictive maintenance of RO membranes in semiconductor wastewater treatment. However, existing prognostic methods often struggle with the complex nonlinear fouling dynamics, periodic cleaning resets, and noisy operating conditions typical of industrial membrane systems. This study provides a predictive foundation for a real-time early warning system for RO maintenance, utilizing a framework combining Sparse Polynomial Identification (SPI) with a Constrained Bayesian Update (CBU) method. The SPI model captures nonlinear membrane degradation through a limited set of power basis functions, and Sparse Bayesian Learning automatically selects the most relevant functions. For real-time predictions, the CBU method employs Posterior Predictive Check (PPC) to assess the reliability of predictions, while Gaussian Mutation enhances particle diversity when reliability decreases. This approach prevents the posterior drift commonly seen in standard Bayesian updating (TBU). The system was developed and validated using 17,880 hourly data points from a full-scale semiconductor wastewater treatment plant, covering two independent RO trains. A multitask architecture addresses two complementary temporal scales: RUL prediction for cleaning cycles (RMSE=81.4, a 43% to 1921% accuracy improvement over traditional methods) and membrane lifetime (RMSE=238.0, 110% to 2421% improvement). When benchmarked against TBU, linear regression, Long-Short-Term-Memory networks, and exponential degradation models, the CBU method consistently demonstrated superior accuracy, better uncertainty calibration, and enhanced computational stability. The GM mechanism keeps PPC acceptance rates close to 1.0, effectively preventing catastrophic posterior collapse amid high inter-cycle variability. This framework relies solely on routine sensor data and is easily transferable to other periodically membrane systems.
- 16 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessConstrained Bayesian Updating Based on Posterior Predictive Checks for Reverse Osmosis Membrane Maintenance in Wastewater Treatment
Reliable prediction of remaining useful life (RUL) is crucial for the predictive maintenance of RO membranes in semiconductor wastewater treatment. However, existing prognostic methods often struggle with the complex nonlinear fouling dynamics, periodic cleaning resets, and noisy operating conditions typical of industrial membrane systems. This study provides a predictive foundation for a real-time early warning system for RO maintenance, utilizing a framework combining Sparse Polynomial Identification (SPI) with a Constrained Bayesian Update (CBU) method. The SPI model captures nonlinear membrane degradation through a limited set of power basis functions, and Sparse Bayesian Learning automatically selects the most relevant functions. For real-time predictions, the CBU method employs Posterior Predictive Check (PPC) to assess the reliability of predictions, while Gaussian Mutation enhances particle diversity when reliability decreases. This approach prevents the posterior drift commonly seen in standard Bayesian updating (TBU). The system was developed and validated using 17,880 hourly data points from a full-scale semiconductor wastewater treatment plant, covering two independent RO trains. A multitask architecture addresses two complementary temporal scales: RUL prediction for cleaning cycles (RMSE=81.4, a 43% to 1921% accuracy improvement over traditional methods) and membrane lifetime (RMSE=238.0, 110% to 2421% improvement). When benchmarked against TBU, linear regression, Long-Short-Term-Memory networks, and exponential degradation models, the CBU method consistently demonstrated superior accuracy, better uncertainty calibration, and enhanced computational stability. The GM mechanism keeps PPC acceptance rates close to 1.0, effectively preventing catastrophic posterior collapse amid high inter-cycle variability. This framework relies solely on routine sensor data and is easily transferable to other periodically membrane systems.
- Open Access
- 24 March 2026
- Published by Elsevier in SSRN Electronic Journal
Interpretable artificial intelligence models for reverse osmosis optimization in semiconductor wastewater treatment: From reactive to proactive operation
Reverse Osmosis (RO) membranes are essential for wastewater polishing in semiconductor manufacturing; however, their operational optimization is hindered by reactive maintenance strategies, limited process transparency, and the lack of data-driven operating guidelines tailored to the specific fouling dynamics of semiconductor wastewater. This study introduces an interpretable artificial intelligence framework for RO membrane optimization, developed using 17,880 hours of operational data from a full-scale semiconductor wastewater treatment plant. Fourteen machine learning models across five algorithmic families (linear, support vector machine, instance-based, ensemble tree, and neural network) were benchmarked following an automated six-method progressive data cleaning (80.3% retention). Extra Trees achieved the best predictive performance (R2 = 0.973, RMSE = 0.234 bar for TMP; R2 = 0.999, RMSE = 0.257 m3/h for permeate flow), validated on an independent RO stream. Multi-model SHAP analysis indicated that membrane age and feed flow rate are the primary predictors of TMP and permeate flow, respectively, while revealing model-dependent biases: linear models misranked feed flow above membrane age for TMP because they fail to capture non-linear fouling accumulation. A Monte Carlo feasibility sampling framework (500,000 evaluations) identified 0.98% of operating conditions that meet simultaneous targets for TMP (≤4.38 bar) and permeate flow (≥207 m3/h), with density-based preferred zones defining robust operating windows: comprehensive chemical cleaning before day 250, a feed flow at 258–259 m3/h, and TOC levels below 4,600 ppb. This integrated framework shifts RO operation from reactive to proactive management, making it directly applicable to other membrane applications with sufficient operational data.
- 24 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessInterpretable artificial intelligence models for reverse osmosis optimization in semiconductor wastewater treatment: From reactive to proactive operation
Reverse Osmosis (RO) membranes are essential for wastewater polishing in semiconductor manufacturing; however, their operational optimization is hindered by reactive maintenance strategies, limited process transparency, and the lack of data-driven operating guidelines tailored to the specific fouling dynamics of semiconductor wastewater. This study introduces an interpretable artificial intelligence framework for RO membrane optimization, developed using 17,880 hours of operational data from a full-scale semiconductor wastewater treatment plant. Fourteen machine learning models across five algorithmic families (linear, support vector machine, instance-based, ensemble tree, and neural network) were benchmarked following an automated six-method progressive data cleaning (80.3% retention). Extra Trees achieved the best predictive performance (R2 = 0.973, RMSE = 0.234 bar for TMP; R2 = 0.999, RMSE = 0.257 m3/h for permeate flow), validated on an independent RO stream. Multi-model SHAP analysis indicated that membrane age and feed flow rate are the primary predictors of TMP and permeate flow, respectively, while revealing model-dependent biases: linear models misranked feed flow above membrane age for TMP because they fail to capture non-linear fouling accumulation. A Monte Carlo feasibility sampling framework (500,000 evaluations) identified 0.98% of operating conditions that meet simultaneous targets for TMP (≤4.38 bar) and permeate flow (≥207 m3/h), with density-based preferred zones defining robust operating windows: comprehensive chemical cleaning before day 250, a feed flow at 258–259 m3/h, and TOC levels below 4,600 ppb. This integrated framework shifts RO operation from reactive to proactive management, making it directly applicable to other membrane applications with sufficient operational data.
- 12 August 2025
- Published by Elsevier in Bioresource Technology
- Vol. 437, 133141
Short-chain fatty acid recovery using superhydrophobic membrane contactors (SHMCs): Transport behavior and real-time wettability monitoring
- 12 August 2025
- Published by Elsevier in Bioresource Technology
- Vol. 437, 133141
Short-chain fatty acid recovery using superhydrophobic membrane contactors (SHMCs): Transport behavior and real-time wettability monitoring