Jumpei Tomita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jumpei Tomita has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Daisuke Suzuki
Research Group for Safeguards Analytical Chemistry, Nuclear Safety Research Center, Nuclear Safety and Emergency Preparedness Institute, Japan Atomic Energy Agency, 2-4 Shirakata, Tokai, Naka, Ibaraki 319-1195, Japan
4 shared publications - Kenichiro Yasuda
Research Group for Safeguards Analytical Chemistry, Nuclear Safety Research Center, Nuclear Safety and Emergency Preparedness Institute, Japan Atomic Energy Agency, 2-4 Shirakata, Tokai, Naka, Ibaraki 319-1195, Japan
4 shared publications - Ryohei Tomita
Research Group for Safeguards Analytical Chemistry, Nuclear Safety Research Center, Nuclear Safety and Emergency Preparedness Institute, Japan Atomic Energy Agency, 2-4 Shirakata, Tokai, Naka, Ibaraki 319-1195, Japan
4 shared publications - Yutaka Miyamoto
Japan Atomic Energy Agency
3 shared publications Masayoshi Yamamoto
Low Level Radioactivity Laboratory, Institute of Nature and Environmental Technology, Kanazawa University, Wake, Nomi, Ishikawa 923-1224, Japan
2 shared publications- Takumi Yomogida
Research Group for Safeguards Analytical Chemistry, Nuclear Safety Research Center, Nuclear Safety and Emergency Preparedness Institute, Japan Atomic Energy Agency, 2-4 Shirakata, Tokai, Naka, Ibaraki 319-1195, Japan
2 shared publications
Latest Publications
- 1 October 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (37) , 8382-8393
Validation of LG-SIMS analysis of plutonium-bearing particles using Pu-impregnated silica particles and its application to the Daigo Fukuryu-Maru sample
Pu-impregnated silica particles enabled controlled validation of LG-SIMS for 240 Pu/ 239 Pu and 242 Pu/ 239 Pu isotope-ratio analysis, followed by particle-scale application to authentic fallout samples.
- 1 October 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (37) , 8382-8393
Validation of LG-SIMS analysis of plutonium-bearing particles using Pu-impregnated silica particles and its application to the Daigo Fukuryu-Maru sample
Pu-impregnated silica particles enabled controlled validation of LG-SIMS for 240 Pu/ 239 Pu and 242 Pu/ 239 Pu isotope-ratio analysis, followed by particle-scale application to authentic fallout samples.
- 17 October 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (44) , 9017-9025
Accurate automatic analysis of individual uranium particles to improve the timeliness of safeguards environmental sample analysis using an LG-SIMS instrument and SEM-micromanipulation
A new method for automated analysis of individual uranium particles using a large-geometry secondary ion mass spectrometry (LG-SIMS) instrument was proposed and demonstrated to improve the timeliness of safeguards environmental sample analysis.
- 17 October 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (44) , 9017-9025
Accurate automatic analysis of individual uranium particles to improve the timeliness of safeguards environmental sample analysis using an LG-SIMS instrument and SEM-micromanipulation
A new method for automated analysis of individual uranium particles using a large-geometry secondary ion mass spectrometry (LG-SIMS) instrument was proposed and demonstrated to improve the timeliness of safeguards environmental sample analysis.
- 12 September 2025
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 63 (4) , 443-454
Simple technique for the preparation of uranium-impregnated porous silica particles and their application as working standard particles for analysis of the safeguards environmental samples
- 12 September 2025
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 63 (4) , 443-454
Simple technique for the preparation of uranium-impregnated porous silica particles and their application as working standard particles for analysis of the safeguards environmental samples
- 17 May 2024
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 35 (6) , 1178-1183
Sensitive 236U/238U Isotopic Analysis of Trace Uranium in Safeguards Environmental Samples Using Multicollector Inductively Coupled Plasma Mass Spectrometry
A sensitive analytical technique was developed for determining a 10(-7) level low U-236/U-238 ratio using multicollector inductively coupled plasma mass spectrometry. This analytical technique can determine the subnanogram amount of uranium in safeguards environmental samples. To increase the sensitivity of the U-236/U-238 ratio, (1) the feed solution was concentrated to one-tenth of that in the conventional method and (2) data acquisition was started from the beginning of the solution uptake until all of the solution was exhausted. All signal intensities were recorded. This technique was applied to the IRMM-184 uranium isotopic standard solution with a 1.2410 x 10(-7)(236)U/U-238 ratio. The IRMM-184 uranium solution (0.2 mL of 1 ng g(-1) uranium) was prepared, and the U-236/U-238 ratios were determined using our new data collection method. The U-236/U-238 ratios were in agreement with the certified value within the uncertainty (k = 2) evaluated using the Guide to the Expression of Uncertainty in Measurement (GUM) workbench. The uncertainties obtained with this new technique (32% on average) were revised to be 10 times smaller than those obtained with the conventional method using 0.1 ng g(-1) IRMM-184. The tailing effect from the U-238 intense peak was determined using 10 times higher concentrations of NBL CRM U0002 uranium isotopic standard solution (10 ng g(-1) uranium) to improve its uncertainty. Approximately 1-2% of the uncertainties of U-236/U-238 could be further reduced using this improved correction factor.
- 17 May 2024
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 35 (6) , 1178-1183
Sensitive 236U/238U Isotopic Analysis of Trace Uranium in Safeguards Environmental Samples Using Multicollector Inductively Coupled Plasma Mass Spectrometry
A sensitive analytical technique was developed for determining a 10(-7) level low U-236/U-238 ratio using multicollector inductively coupled plasma mass spectrometry. This analytical technique can determine the subnanogram amount of uranium in safeguards environmental samples. To increase the sensitivity of the U-236/U-238 ratio, (1) the feed solution was concentrated to one-tenth of that in the conventional method and (2) data acquisition was started from the beginning of the solution uptake until all of the solution was exhausted. All signal intensities were recorded. This technique was applied to the IRMM-184 uranium isotopic standard solution with a 1.2410 x 10(-7)(236)U/U-238 ratio. The IRMM-184 uranium solution (0.2 mL of 1 ng g(-1) uranium) was prepared, and the U-236/U-238 ratios were determined using our new data collection method. The U-236/U-238 ratios were in agreement with the certified value within the uncertainty (k = 2) evaluated using the Guide to the Expression of Uncertainty in Measurement (GUM) workbench. The uncertainties obtained with this new technique (32% on average) were revised to be 10 times smaller than those obtained with the conventional method using 0.1 ng g(-1) IRMM-184. The tailing effect from the U-238 intense peak was determined using 10 times higher concentrations of NBL CRM U0002 uranium isotopic standard solution (10 ng g(-1) uranium) to improve its uncertainty. Approximately 1-2% of the uncertainties of U-236/U-238 could be further reduced using this improved correction factor.
- 28 March 2024
- Published by Elsevier in Chemosphere
- Vol. 355, 141837
Microbially formed Mn(IV) oxide as a novel adsorbent for removal of Radium
- 28 March 2024
- Published by Elsevier in Chemosphere
- Vol. 355, 141837
Microbially formed Mn(IV) oxide as a novel adsorbent for removal of Radium
- 1 August 2019
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 150, 103-109
Rapid analytical method of 90Sr in urine sample: Rapid separation of Sr by phosphate co-precipitation and extraction chromatography, followed by determination by triple quadrupole inductively coupled plasma mass spectrometry (ICP-MS/MS)
- 1 August 2019
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 150, 103-109
Rapid analytical method of 90Sr in urine sample: Rapid separation of Sr by phosphate co-precipitation and extraction chromatography, followed by determination by triple quadrupole inductively coupled plasma mass spectrometry (ICP-MS/MS)
- 1 November 2014
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 137, 204-212
Radium isotopes (226Ra and 228Ra) in Na–Cl type groundwaters from Tohoku District (Aomori, Akita and Yamagata Prefectures) in Japan
- 1 November 2014
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 137, 204-212
Radium isotopes (226Ra and 228Ra) in Na–Cl type groundwaters from Tohoku District (Aomori, Akita and Yamagata Prefectures) in Japan
- 9 September 2013
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 299 (1) , 569-575
Salinity dependence of 226Ra adsorption on montmorillonite and kaolinite
- 9 September 2013
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 299 (1) , 569-575
Salinity dependence of 226Ra adsorption on montmorillonite and kaolinite