WLWei Lin

Wei Lin

*This is an algorithmically generated author record based on publicly available information.

Wei Lin has a total of 12 co-authors. Here are the top co-authors by number of shared publications:

  • Anmin Hu

    Department of Anesthesia, Shenzhen Peoples Hospital, Shenzhen, China

    5 shared publications
  • Jian Huo

    Boston Intelligent Medical Research Center, Shenzhen United Scheme Technology Company Limited, Boston, MA, United States

    5 shared publications
  • Chaoran Wu

    Department of Anesthesiology, Shenzhen People’s Hospital, The First Affiliated Hospital, Southern University of Science and Technology, Shenzhen, China, sustc.edu.cn

    4 shared publications
  • Yan Yu

    Department of Anesthesia, Shenzhen People's Hospital, The First Affiliated Hospital of Southern University of Science and Technology, Shenzhen Key Medical Discipline, Shenzhen, China

    4 shared publications
  • Chaoran Wu

    Department of Anesthesia, Shenzhen Peoples Hospital, Shenzhen, China

    1 shared publication
  • Hong Xu

    School of Energy and Power Engineering, Beihang University, Beijing, China

    1 shared publication

Latest Publications

  • Value Decomposition-Based Multi-Agent Learning for Anesthetics Collaborative Control

    by Huijie Li, Yide Yu, Si Shi, Anmin Hu, Jian Huo, Wei Lin, Chaoran Wu, Wuman Luo

    Automated control of personalized multiple anesthetics in clinical Total Intravenous Anesthesia (TIVA) is crucial yet challenging. Current systems, including target-controlled infusion (TCI) and closedloop systems, either rely on relatively static pharmacokinetic/pharmacodynamic (PK/PD) models or focus on single anesthetic control. So they limit both personalization and collaborative control. To address these issues, we propose a novel Value Decomposition MultiAgent Deep Reinforcement Learning (VD-MADRL) framework based on Markov Game (MG) for Personalized Multiple Anesthetics Control in a Closed-Loop system (PMAC-CL). VD-MADRL optimizes the collaboration between two anesthetics propofol (Agent I) and remifentanil (Agent II) by leveraging a MG to identify optimal actions among heterogeneous agents. We employ various value function decomposition methods to resolve the credit allocation problem and enhance collaborative control. We also introduce a multivariate environment model based on random forest (RF) for anesthesia state simulation. To ensure data validity, we design a data resampling and alignment technique to synchronize trajectory data from different devices, avoiding gradient explosion and maintaining conformity to Markov property. Extensive experiments on general and thoracic surgery datasets demonstrate that VD-MADRL provides more refined dose adjustments and maintains multiple anesthesia state indicators more stably at target levels compared to human experience. Especially, the bestperforming algorithm, VDN in general surgery with online training, achieved a 16.4% increase in cumulative reward (CR) and a 58.0% reduction in mean MDPE compared to human experience. This demonstrates its great clinical value


  • Open Access

    Correction: Application of AI in Multilevel Pain Assessment Using Facial Images: Systematic Review and Meta-Analysis (Preprint)

    by Jian Huo, Yan Yu, Wei Lin, Anmin Hu, Chaoran Wu

    Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author).

  • Open Access

    Correction: Application of AI in Multilevel Pain Assessment Using Facial Images: Systematic Review and Meta-Analysis

    by Jian Huo, Yan Yu, Wei Lin, Anmin Hu, Chaoran Wu

    [This corrects the article DOI: 10.2196/51250.].


  • Open Access

    Application of AI in Multilevel Pain Assessment Using Facial Images: Systematic Review and Meta-Analysis

    by Jian Huo, Yan Yu, Wei Lin, Anmin Hu, Chaoran Wu

    Background: The continuous monitoring and recording of patients’ pain status is a major problem in current research on postoperative pain management. In the large number of original or review articles focusing on different approaches for pain assessment, many researchers have investigated how computer vision (CV) can help by capturing facial expressions. However, there is a lack of proper comparison of results between studies to identify current research gaps. Objective: The purpose of this systematic review and meta-analysis was to investigate the diagnostic performance of artificial intelligence models for multilevel pain assessment from facial images. Methods: The PubMed, Embase, IEEE, Web of Science, and Cochrane Library databases were searched for related publications before September 30, 2023. Studies that used facial images alone to estimate multiple pain values were included in the systematic review. A study quality assessment was conducted using the Quality Assessment of Diagnostic Accuracy Studies, 2nd edition tool. The performance of these studies was assessed by metrics including sensitivity, specificity, log diagnostic odds ratio (LDOR), and area under the curve (AUC). The intermodal variability was assessed and presented by forest plots. Results: A total of 45 reports were included in the systematic review. The reported test accuracies ranged from 0.27-0.99, and the other metrics, including the mean standard error (MSE), mean absolute error (MAE), intraclass correlation coefficient (ICC), and Pearson correlation coefficient (PCC), ranged from 0.31-4.61, 0.24-2.8, 0.19-0.83, and 0.48-0.92, respectively. In total, 6 studies were included in the meta-analysis. Their combined sensitivity was 98% (95% CI 96%-99%), specificity was 98% (95% CI 97%-99%), LDOR was 7.99 (95% CI 6.73-9.31), and AUC was 0.99 (95% CI 0.99-1). The subgroup analysis showed that the diagnostic performance was acceptable, although imbalanced data were still emphasized as a major problem. All studies had at least one domain with a high risk of bias, and for 20% (9/45) of studies, there were no applicability concerns. Conclusions: This review summarizes recent evidence in automatic multilevel pain estimation from facial expressions and compared the test accuracy of results in a meta-analysis. Promising performance for pain estimation from facial images was established by current CV algorithms. Weaknesses in current studies were also identified, suggesting that larger databases and metrics evaluating multiclass classification performance could improve future studies. Trial Registration: PROSPERO CRD42023418181; https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=418181


  • Open Access

    Application of AI in in Multilevel Pain Assessment Using Facial Images: Systematic Review and Meta-Analysis (Preprint)

    by Jian Huo, Yan Yu, Wei Lin, Anmin Hu, Chaoran Wu

    BACKGROUND The continuous monitoring and recording of patients’ pain status is a major problem in current research on postoperative pain management. In the large number of original or review articles focusing on different approaches for pain assessment, many researchers have investigated how computer vision (CV) can help by capturing facial expressions. However, there is a lack of proper comparison of results between studies to identify current research gaps. OBJECTIVE The purpose of this systematic review and meta-analysis was to investigate the diagnostic performance of artificial intelligence models for multilevel pain assessment from facial images. METHODS The PubMed, Embase, IEEE, Web of Science, and Cochrane Library databases were searched for related publications before September 30, 2023. Studies that used facial images alone to estimate multiple pain values were included in the systematic review. A study quality assessment was conducted using the Quality Assessment of Diagnostic Accuracy Studies, 2nd edition tool. The performance of these studies was assessed by metrics including sensitivity, specificity, log diagnostic odds ratio (LDOR), and area under the curve (AUC). The intermodal variability was assessed and presented by forest plots. RESULTS A total of 45 reports were included in the systematic review. The reported test accuracies ranged from 0.27-0.99, and the other metrics, including the mean standard error (MSE), mean absolute error (MAE), intraclass correlation coefficient (ICC), and Pearson correlation coefficient (PCC), ranged from 0.31-4.61, 0.24-2.8, 0.19-0.83, and 0.48-0.92, respectively. In total, 6 studies were included in the meta-analysis. Their combined sensitivity was 98% (95% CI 96%-99%), specificity was 98% (95% CI 97%-99%), LDOR was 7.99 (95% CI 6.73-9.31), and AUC was 0.99 (95% CI 0.99-1). The subgroup analysis showed that the diagnostic performance was acceptable, although imbalanced data were still emphasized as a major problem. All studies had at least one domain with a high risk of bias, and for 20% (9/45) of studies, there were no applicability concerns. CONCLUSIONS This review summarizes recent evidence in automatic multilevel pain estimation from facial expressions and compared the test accuracy of results in a meta-analysis. Promising performance for pain estimation from facial images was established by current CV algorithms. Weaknesses in current studies were also identified, suggesting that larger databases and metrics evaluating multiclass classification performance could improve future studies. CLINICALTRIAL PROSPERO CRD42023418181; https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=418181

  • Study on Measurement of Polymer Orientation Degree Base on SVM

    by Yan Wang, Wei Guo Lin, Hong Xu, Tao Liu

    Aiming at the difficulty of measuring orientation degree of polymer material online, a soft-sensing approach based on ultrasonic velocity measurement is proposed.Firstly, the ultrasonic velocities of polymer samples are measured using a DSP-based ultrasonic velocity measurement circuit, with the ultrasonic sensor perpendicular to the extrusion direction of polymer material, the orientation degrees of samples are calibrated with infrared spectroscopy, the relationship between the ultrasonic velocities and the orientation degrees are then established based on SVM. With the measurement model and the ultrasonic velocity measured online, the orientation degree of polymer material can then be measured online. Test results in Lab shows that this approach can implement accurate measurement, and the relative error is about 5%.