XZXiaoyong Zhang

Xiaoyong Zhang

*This is an algorithmically generated author record based on publicly available information.

Xiaoyong Zhang has a total of 21 co-authors. Here are the top co-authors by number of shared publications:

  • Bin Song

    Department of Radiology, Functional and Molecular Imaging Key Laboratory of Sichuan Province, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China

    1 shared publication
  • Chun-Chao Xia

    Department of Radiology, West China Hospital of Sichuan University, Chengdu, China

    1 shared publication
  • Emily Lerner

    Department of Radiology, Duke University Medical Center, Durham, NC 27710, USA

    1 shared publication
  • Hanyu Jiang

    Department of Radiology West China Hospital, Sichuan University Chengdu China

    1 shared publication
  • Jie Chen

    Department of Radiology, Functional and Molecular Imaging Key Laboratory of Sichuan Province, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China

    1 shared publication
  • Jie Chen

    Department of Radiology, West China Hospital, Sichuan University, Chengdu, China

    1 shared publication

Latest Publications

  • Enhanced diagnostic performance of WE-SHARP-DWI compared with SPAIR-DWI for focal liver lesion evaluation at 3T

    by Xinyu Liu, Lanqing Yang, Yu Zhang, Sixian Hu, Yunlong Hu, Ruolan Sun, Meng Qin, Jie Chen, Xiaoyong Zhang, Ting Yin, et al.

    Purpose This study aimed to compare the diagnostic performance of 2 fat suppression techniques in diffusion-weighted imaging (DWI) for detecting and assessing focal liver lesions (FLLs): water excitation spectral heterogeneity adaptive radiofrequency pulses (WE-SHARP) and conventional spectral adiabatic inversion recovery (SPAIR). Materials and methods This prospective study enrolled eligible participants between October 2023 and August 2024. Various DWI techniques at 3T, SPAIR-DWI, WE-SHARP-DWI, and WE-SHARP-DWI with correction algorithms (WE-SHARP-DWI*), acquired at b values of 50, 400, 800, and 1200 s/mm², were used to evaluate FLLs. Two radiologists independently assessed several subjective image quality parameters: liver edge sharpness, vessel delineation, lesion conspicuity, fat suppression effectiveness, artifacts, and overall image quality. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) values were also measured. The diagnostic performance of all 3 sequences was evaluated using receiver operating characteristic (ROC) curve analysis. Results The study included 158 patients (67 with malignant and 91 with benign lesions) and 25 volunteers. Compared with SPAIR-DWI, the subjective image quality parameters were superior for both WE-SHARP sequences (P < .001). SNR increased 2.15-fold with WE-SHARP-DWI and 2.93-fold with WE-SHARP-DWI*. CNR also improved substantially with the WE-SHARP sequences (30.75 ± 36.83 and 42.43 ± 53.23 vs. 13.49 ± 14.39). Further, WE-SHARP sequences demonstrated lower ADC measurement variability with lower standard deviations (32.80 ± 19.13 × 10⁻³ mm²/s and 34.39 ± 18.22 × 10⁻³ mm²/s vs. 51.48 ± 17.89 × 10⁻³ mm²/s) in normal liver and more pronounced ADC differences between benign and malignant lesions (1179 × 10⁻3 mm²/s and 1197 × 10⁻3 mm²/s vs. 1009 × 10⁻3 mm²/s.). The WE-SHARP-DWI techniques demonstrated improved diagnostic performance with higher sensitivity (0.95 vs. 0.88) and greater area under the ROC curve (0.98 vs. 0.95) compared with SPAIR-DWI. Conclusions Both WE-SHARP-DWI techniques demonstrated superior image quality and diagnostic value for assessing FLLs than the conventional SPAIR technique. These techniques retained clinically acceptable image quality even at high b values.


  • Deep learning-based compressed SENSE improved diffusion-weighted image quality and liver cancer detection: A prospective study

    by Ting Duan, Zhen Zhang, Yidi Chen, Mustafa R. Bashir, Emily Lerner, YaLi Qu, Jie Chen, Xiaoyong Zhang, Bin Song, Hanyu Jiang