Yosuke Ogata
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yosuke Ogata has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Shun Okuwaki
Department of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba, Japan
4 shared publications - Hisanori Gamada
Department of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba, Japan
3 shared publications - Kotaro Sakashita
Department of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba, Japan
3 shared publications - Masao Koda
Department of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba, Japan
3 shared publications - Seiji Ohtori
Department of Orthopaedic Surgery, Graduate School of Medicine, Chiba University, Chiba, Japan
3 shared publications - Takahiro Sunami
Department of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba, Japan
3 shared publications
Latest Publications
- 29 September 2026
- Published by Wolters Kluwer Health in Spine
Modified Lenke Classification Stratifies Brace Initiation Risk and Longitudinal Cobb Angles Trajectories in Female Patients With Adolescent Idiopathic Scoliosis
Study Design.: Retrospective single-center cohort study. Objective.: To determine whether baseline modified Lenke classification (MLC), assessed from standing whole-spine radiographs, stratifies brace initiation risk and longitudinal Cobb-angle trajectories in female patients with adolescent idiopathic scoliosis (AIS) before reaching the conventional bracing threshold. Summary of Background Data.: AIS progression is heterogeneous. Baseline Cobb angle and skeletal maturity are established risk factors, but whether simple baseline curve-pattern classification adds risk-stratification information during nonoperative follow-up remains unclear. Methods.: We included female AIS patients aged 10 to P =0.002) and reduced AICc, although BIC increased. At baseline Cobb 20°, adjusted 2-year risk ranged from 23.3% in MLC 1 to 55.9% in MLC 4. Longitudinal Cobb-angle trajectories differed according to MLC. Conclusion.: Baseline MLC may provide complementary information for stratifying brace-initiation risk and longitudinal Cobb-angle trajectories before the conventional bracing threshold.
- 29 September 2026
- Published by Wolters Kluwer Health in Spine
Modified Lenke Classification Stratifies Brace Initiation Risk and Longitudinal Cobb Angles Trajectories in Female Patients With Adolescent Idiopathic Scoliosis
Study Design.: Retrospective single-center cohort study. Objective.: To determine whether baseline modified Lenke classification (MLC), assessed from standing whole-spine radiographs, stratifies brace initiation risk and longitudinal Cobb-angle trajectories in female patients with adolescent idiopathic scoliosis (AIS) before reaching the conventional bracing threshold. Summary of Background Data.: AIS progression is heterogeneous. Baseline Cobb angle and skeletal maturity are established risk factors, but whether simple baseline curve-pattern classification adds risk-stratification information during nonoperative follow-up remains unclear. Methods.: We included female AIS patients aged 10 to P =0.002) and reduced AICc, although BIC increased. At baseline Cobb 20°, adjusted 2-year risk ranged from 23.3% in MLC 1 to 55.9% in MLC 4. Longitudinal Cobb-angle trajectories differed according to MLC. Conclusion.: Baseline MLC may provide complementary information for stratifying brace-initiation risk and longitudinal Cobb-angle trajectories before the conventional bracing threshold.
- Open Access
- 31 August 2026
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 20 (4) , 834-835
Response to the letter to the editor: Impact of abscess type on outcomes following posterior fixation for thoracolumbar pyogenic spondylitis: a multicenter retrospective cohort study
... Asian Spine Journal 2026;20(4):834-835.
- 31 August 2026
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 20 (4) , 834-835
Open AccessResponse to the letter to the editor: Impact of abscess type on outcomes following posterior fixation for thoracolumbar pyogenic spondylitis: a multicenter retrospective cohort study
... Asian Spine Journal 2026;20(4):834-835.
- Open Access
- 6 January 2026
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 20 (3) , 455-465
Impact of abscess type on outcomes following posterior fixation for thoracolumbar pyogenic spondylitis: a multicenter retrospective cohort study
Study Design: Multicenter retrospective cohort study. Purpose: To evaluate the impact of abscess presence and type on treatment duration and clinical outcomes in patients undergoing minimally invasive posterior fixation for thoracolumbar pyogenic spondylitis. Overview of Literature: Surgical management is increasingly favored for pyogenic spondylitis. Abscesses, particularly epidural and iliopsoas, have been linked to poorer prognoses, and empyema, though uncommon, tends to be particularly severe. However, the effect of specific abscess types on surgical outcomes remains unclear. Methods: This study included 92 patients who underwent minimally invasive posterior fixation across 10 centers between 2014 and 2024. Patients were classified into an abscess group (epidural, iliopsoas, empyema, or other) and a non-abscess group. Clinical outcomes, including total duration of intravenous antibiotics and unplanned additional surgeries, were compared. Subgroup and regression analyses were conducted to assess the impact of specific abscess type. Results: Abscesses were present in 65 patients (71%): epidural (n=51), iliopsoas (n=38), and empyema (n=3), with some overlap. Compared with the non-abscess group (n=27; 29%), there were no significant differences in antibiotic duration or rates of unplanned additional surgery. However, iliopsoas abscess was associated with longer antibiotic duration (8.1 weeks vs. 6.6 weeks, p=0.044), while all empyema cases required additional surgery for poor infection control (p=0.000). Regression analysis identified iliopsoas abscess and age ≥65 years as independent predictors of prolonged antibiotic use, whereas epidural abscess was associated with shorter antibiotic duration. Conclusions: Iliopsoas abscesses were associated with longer antibiotic courses, while empyema was linked to poor infection control and a higher likelihood of additional surgery.
- 6 January 2026
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 20 (3) , 455-465
Open AccessImpact of abscess type on outcomes following posterior fixation for thoracolumbar pyogenic spondylitis: a multicenter retrospective cohort study
Study Design: Multicenter retrospective cohort study. Purpose: To evaluate the impact of abscess presence and type on treatment duration and clinical outcomes in patients undergoing minimally invasive posterior fixation for thoracolumbar pyogenic spondylitis. Overview of Literature: Surgical management is increasingly favored for pyogenic spondylitis. Abscesses, particularly epidural and iliopsoas, have been linked to poorer prognoses, and empyema, though uncommon, tends to be particularly severe. However, the effect of specific abscess types on surgical outcomes remains unclear. Methods: This study included 92 patients who underwent minimally invasive posterior fixation across 10 centers between 2014 and 2024. Patients were classified into an abscess group (epidural, iliopsoas, empyema, or other) and a non-abscess group. Clinical outcomes, including total duration of intravenous antibiotics and unplanned additional surgeries, were compared. Subgroup and regression analyses were conducted to assess the impact of specific abscess type. Results: Abscesses were present in 65 patients (71%): epidural (n=51), iliopsoas (n=38), and empyema (n=3), with some overlap. Compared with the non-abscess group (n=27; 29%), there were no significant differences in antibiotic duration or rates of unplanned additional surgery. However, iliopsoas abscess was associated with longer antibiotic duration (8.1 weeks vs. 6.6 weeks, p=0.044), while all empyema cases required additional surgery for poor infection control (p=0.000). Regression analysis identified iliopsoas abscess and age ≥65 years as independent predictors of prolonged antibiotic use, whereas epidural abscess was associated with shorter antibiotic duration. Conclusions: Iliopsoas abscesses were associated with longer antibiotic courses, while empyema was linked to poor infection control and a higher likelihood of additional surgery.
- Open Access
- 18 November 2025
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 20 (2) , 302-312
Insufficient evaluation of S2 alar iliac screw malposition with the intraoperative inlet view: utility of the obturator inlet and iliac oblique views
Retrospective observational study. To evaluate the effectiveness of the inlet view in detecting anterior deviations of the S2 alar iliac (S2AI) screw during spinopelvic surgery and to assess the utility of the obturator inlet (OI) and iliac oblique (IO) views as alternative imaging methods. S2AI screws are increasingly utilized in spinopelvic fixation due to their biomechanical advantages. However, malpositioning of screws can lead to neurovascular complications. While inlet views in fluoroscopic techniques are generally effective for identifying screw deviations, there are instances where deviations go unnoticed. We analyzed data from 101 patients who underwent spinopelvic surgery involving 202 S2AI screws. Postoperative computed tomography (CT) images were reviewed to identify screw deviations. The reconstructed fluoroscopic views from CT, including the inlet, OI, and IO views, were assessed for their effectiveness in detecting deviations. An experimental study using pelvic bone models simulated scenarios where deviations were undetectable in the inlet view but visible in the OI view. Screw deviations were identified in 12 cases (11.9%) and 13 screws (6.4%), including six screws (3.0%) with anterior deviations and seven screws (3.5%) with posterior deviations. The accurate inlet view detected anterior deviations in three of the five cases analyzed with reconstructed images. However, two cases of anterior deviation were missed due to an insufficient inlet view caused by a 30° caudal tilting angle. In contrast, the OI view successfully identified all cases of both anterior and posterior deviations. In particular, deviations above the arcuate line of the pelvic brim were not detectable in the inlet view. The inlet view alone is inadequate for detecting anterior deviations, especially those located above the arcuate line of the pelvis. The OI and IO views demonstrated greater effectiveness in identifying deviations, thereby enhancing the accuracy and safety of S2AI screw placement.
- 18 November 2025
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 20 (2) , 302-312
Open AccessInsufficient evaluation of S2 alar iliac screw malposition with the intraoperative inlet view: utility of the obturator inlet and iliac oblique views
Retrospective observational study. To evaluate the effectiveness of the inlet view in detecting anterior deviations of the S2 alar iliac (S2AI) screw during spinopelvic surgery and to assess the utility of the obturator inlet (OI) and iliac oblique (IO) views as alternative imaging methods. S2AI screws are increasingly utilized in spinopelvic fixation due to their biomechanical advantages. However, malpositioning of screws can lead to neurovascular complications. While inlet views in fluoroscopic techniques are generally effective for identifying screw deviations, there are instances where deviations go unnoticed. We analyzed data from 101 patients who underwent spinopelvic surgery involving 202 S2AI screws. Postoperative computed tomography (CT) images were reviewed to identify screw deviations. The reconstructed fluoroscopic views from CT, including the inlet, OI, and IO views, were assessed for their effectiveness in detecting deviations. An experimental study using pelvic bone models simulated scenarios where deviations were undetectable in the inlet view but visible in the OI view. Screw deviations were identified in 12 cases (11.9%) and 13 screws (6.4%), including six screws (3.0%) with anterior deviations and seven screws (3.5%) with posterior deviations. The accurate inlet view detected anterior deviations in three of the five cases analyzed with reconstructed images. However, two cases of anterior deviation were missed due to an insufficient inlet view caused by a 30° caudal tilting angle. In contrast, the OI view successfully identified all cases of both anterior and posterior deviations. In particular, deviations above the arcuate line of the pelvic brim were not detectable in the inlet view. The inlet view alone is inadequate for detecting anterior deviations, especially those located above the arcuate line of the pelvis. The OI and IO views demonstrated greater effectiveness in identifying deviations, thereby enhancing the accuracy and safety of S2AI screw placement.
- 2 June 2025
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 51 (1) , 1-9
Comparison of the O-arm-based navigation system with conventional fluoroscopy for percutaneous screw fixation in patients with fragility fractures of the pelvis
Purpose Fragility fractures of the pelvis (FFPs) are increasingly common owing to aging populations of several countries and the increasing osteoporosis incidence. Surgical interventions, including percutaneous screw fixation, are performed to avoid complications associated with prolonged bed rest for FFP management. However, conventional fluoroscopy for surgical navigation is difficult owing to issues such as insufficient tissue imaging, difficulty achieving accurate screw placement, and high radiation exposure to surgeons. This study aimed to compare the effectiveness of the O-arm-based navigation system with that of conventional fluoroscopy for percutaneous screw fixation in patients with FFPs, focusing on surgical outcomes, radiation exposure, and screw-placement accuracy. Methods This retrospective multicenter study was conducted between April 2020 and May 2024. Seventy-two patients with FFPs were divided into two groups: O-arm (O, n = 14) and the conventional fluoroscopy (C, n = 58) groups. Primary evaluation parameters were radiation exposure and screw-placement accuracy. Demographic and surgical data, including surgery duration and intraoperative blood loss, were collected for secondary evaluation. Results There was no significant differences in demographic data between groups. Surgeon radiation exposure was lower in the O group (0.1–0.2 µSv) than in the C group (mean exposure: 109.8 ± 61.3 mGy). The screw-perforation rate was lower in the O group (5.7%) than in the C group (20%). No patients in the O group required reoperation; however, three patients in the C group did. Conclusion Compared with conventional fluoroscopy, the O-arm-based navigation system improves screw-placement accuracy and significantly reduces surgeon radiation exposure.
- 2 June 2025
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 51 (1) , 1-9
Comparison of the O-arm-based navigation system with conventional fluoroscopy for percutaneous screw fixation in patients with fragility fractures of the pelvis
Purpose Fragility fractures of the pelvis (FFPs) are increasingly common owing to aging populations of several countries and the increasing osteoporosis incidence. Surgical interventions, including percutaneous screw fixation, are performed to avoid complications associated with prolonged bed rest for FFP management. However, conventional fluoroscopy for surgical navigation is difficult owing to issues such as insufficient tissue imaging, difficulty achieving accurate screw placement, and high radiation exposure to surgeons. This study aimed to compare the effectiveness of the O-arm-based navigation system with that of conventional fluoroscopy for percutaneous screw fixation in patients with FFPs, focusing on surgical outcomes, radiation exposure, and screw-placement accuracy. Methods This retrospective multicenter study was conducted between April 2020 and May 2024. Seventy-two patients with FFPs were divided into two groups: O-arm (O, n = 14) and the conventional fluoroscopy (C, n = 58) groups. Primary evaluation parameters were radiation exposure and screw-placement accuracy. Demographic and surgical data, including surgery duration and intraoperative blood loss, were collected for secondary evaluation. Results There was no significant differences in demographic data between groups. Surgeon radiation exposure was lower in the O group (0.1–0.2 µSv) than in the C group (mean exposure: 109.8 ± 61.3 mGy). The screw-perforation rate was lower in the O group (5.7%) than in the C group (20%). No patients in the O group required reoperation; however, three patients in the C group did. Conclusion Compared with conventional fluoroscopy, the O-arm-based navigation system improves screw-placement accuracy and significantly reduces surgeon radiation exposure.
- 31 January 2025
- Published by Elsevier in The Spine Journal
- Vol. 25 (8) , 1708-1718
Timeline of curve progression around menarche in small adolescent idiopathic scoliosis curves without influence of braces: a single-center longitudinal cohort study of 1,090 patients
- 31 January 2025
- Published by Elsevier in The Spine Journal
- Vol. 25 (8) , 1708-1718
Timeline of curve progression around menarche in small adolescent idiopathic scoliosis curves without influence of braces: a single-center longitudinal cohort study of 1,090 patients
- Open Access
- 31 August 2024
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 18 (4) , 579-586
Risk factors for allogeneic red blood cell transfusion in adult spinal deformity surgery
Study Design: Retrospective study.Purpose: To investigate the risk factors for allogeneic red blood cell (RBC) transfusion in adult spinal deformity (ASD) surgery.Overview of Literature: Studies have not thoroughly explored the roles of intraoperative hypothermia, autologous blood donation, and hemostatic agent administration, which would provide a better understanding of the risk for perioperative RBC transfusion in ASD surgery.Methods: The medical records of 151 patients with ASD who underwent correction surgery between 2012 and 2021 were retrospectively reviewed. Estimated blood loss and perioperative allogeneic transfusion were examined. Patients were categorized into two groups based on whether they received perioperative allogeneic blood transfusion. Logistic regression analysis was employed to investigate the effect of age, sex, blood type, body mass index, American Society of Anesthesiologists’ physical status, preoperative hemoglobin level, autologous blood donation, global spine alignment parameters, preoperative use of anticoagulants or antiplatelet medicine and nonsteroidal anti-inflammatory drugs, number of instrumented fusion levels, total operative duration, three-column osteotomy, lateral interbody fusion, pelvic fixation, intraoperative hypothermia, use of gelatin-thrombin based hemostatic agents, and intraoperative tranexamic acid (TXA) with simultaneous exposure by two attending surgeons.Results: The estimated blood loss was 994.2±754.5 mL, and 71 patients (47.0%) received allogeneic blood transfusion. In the logistic regression analysis, the absence of intraoperative TXA use and simultaneous exposure (odds ratio [OR], 26.3; 95% confidence interval [CI], 7.6–90.9; p<0.001), lack of autologous blood donation (OR, 21.2; 95% CI, 4.4–100.0; p<0.001), and prolonged operative duration (OR, 1.6; 95% CI, 1.3–1.9; p<0.001) were significant independent factors for perioperative allogeneic blood transfusion in ASD surgery.Conclusions: Autologous blood storage, intraoperative TXA administration, and simultaneous exposure should be considered to minimize perioperative allogeneic blood transfusion in ASD surgery, particularly in patients with anticipated lengthy surgeries.
- 31 August 2024
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 18 (4) , 579-586
Open AccessRisk factors for allogeneic red blood cell transfusion in adult spinal deformity surgery
Study Design: Retrospective study.Purpose: To investigate the risk factors for allogeneic red blood cell (RBC) transfusion in adult spinal deformity (ASD) surgery.Overview of Literature: Studies have not thoroughly explored the roles of intraoperative hypothermia, autologous blood donation, and hemostatic agent administration, which would provide a better understanding of the risk for perioperative RBC transfusion in ASD surgery.Methods: The medical records of 151 patients with ASD who underwent correction surgery between 2012 and 2021 were retrospectively reviewed. Estimated blood loss and perioperative allogeneic transfusion were examined. Patients were categorized into two groups based on whether they received perioperative allogeneic blood transfusion. Logistic regression analysis was employed to investigate the effect of age, sex, blood type, body mass index, American Society of Anesthesiologists’ physical status, preoperative hemoglobin level, autologous blood donation, global spine alignment parameters, preoperative use of anticoagulants or antiplatelet medicine and nonsteroidal anti-inflammatory drugs, number of instrumented fusion levels, total operative duration, three-column osteotomy, lateral interbody fusion, pelvic fixation, intraoperative hypothermia, use of gelatin-thrombin based hemostatic agents, and intraoperative tranexamic acid (TXA) with simultaneous exposure by two attending surgeons.Results: The estimated blood loss was 994.2±754.5 mL, and 71 patients (47.0%) received allogeneic blood transfusion. In the logistic regression analysis, the absence of intraoperative TXA use and simultaneous exposure (odds ratio [OR], 26.3; 95% confidence interval [CI], 7.6–90.9; p<0.001), lack of autologous blood donation (OR, 21.2; 95% CI, 4.4–100.0; p<0.001), and prolonged operative duration (OR, 1.6; 95% CI, 1.3–1.9; p<0.001) were significant independent factors for perioperative allogeneic blood transfusion in ASD surgery.Conclusions: Autologous blood storage, intraoperative TXA administration, and simultaneous exposure should be considered to minimize perioperative allogeneic blood transfusion in ASD surgery, particularly in patients with anticipated lengthy surgeries.
- Open Access
- 27 March 2024
- Published by Japanese Society for Spine Surgery and Related Research in Spine Surgery and Related Research
- Vol. 8 (2) , 180-187
The Optimal Patient Position on the Surgical Table for Lateral Lumbar Interbody Fusion in Adult Spinal Deformity Using Three-Dimensional Computed Tomography: A Retrospective Study
Introduction: Lateral lumbar interbody fusion (LLIF) techniques have been extensively used in adult spinal deformity surgery. Preoperative knowledge of the optimal position of the patient on the surgical table is essential for a safe procedure. Therefore, this study aims to determine the optimal angle for positioning the patient on the surgical table during LLIF using three-dimensional computed tomography (3DCT).Methods: Data from 59 patients (2 males, 57 females, mean age 66.3±8.6 years) with adult spinal deformities treated by performing corrective spinal surgery were included in this observational retrospective study. Simulated fluoroscopic images were obtained using 3DCT images rotated from the reference position with the spinous process of S1 as the midline to the position with the spinous process in the center of the bilateral pedicle of T12-L5. The rotation angle of each vertebra was measured and defined as the optimal rotation angle (ORA). The angle that bisected the angle between the maximum and minimum ORA was defined as the optimal mean angle of the maximum and minimum ORA (OMA) and considered the optimal angle for the patient's position on the surgical table, as this position could minimize the rotation angle of the surgical table during surgery. A multiple regression analysis was performed to predict OMA.Results: Multiple regression analysis revealed the following equation: OMA=1.959+ (0.238×lumbar coronal Cobb angle) + (−0.208×sagittal vertical axis).Conclusions: When the patient is placed on the surgical table by rotating them at the OMA, the rotation of the surgical table can be reduced, ensuring a safe and efficient surgical procedure.
- 27 March 2024
- Published by Japanese Society for Spine Surgery and Related Research in Spine Surgery and Related Research
- Vol. 8 (2) , 180-187
Open AccessThe Optimal Patient Position on the Surgical Table for Lateral Lumbar Interbody Fusion in Adult Spinal Deformity Using Three-Dimensional Computed Tomography: A Retrospective Study
Introduction: Lateral lumbar interbody fusion (LLIF) techniques have been extensively used in adult spinal deformity surgery. Preoperative knowledge of the optimal position of the patient on the surgical table is essential for a safe procedure. Therefore, this study aims to determine the optimal angle for positioning the patient on the surgical table during LLIF using three-dimensional computed tomography (3DCT).Methods: Data from 59 patients (2 males, 57 females, mean age 66.3±8.6 years) with adult spinal deformities treated by performing corrective spinal surgery were included in this observational retrospective study. Simulated fluoroscopic images were obtained using 3DCT images rotated from the reference position with the spinous process of S1 as the midline to the position with the spinous process in the center of the bilateral pedicle of T12-L5. The rotation angle of each vertebra was measured and defined as the optimal rotation angle (ORA). The angle that bisected the angle between the maximum and minimum ORA was defined as the optimal mean angle of the maximum and minimum ORA (OMA) and considered the optimal angle for the patient's position on the surgical table, as this position could minimize the rotation angle of the surgical table during surgery. A multiple regression analysis was performed to predict OMA.Results: Multiple regression analysis revealed the following equation: OMA=1.959+ (0.238×lumbar coronal Cobb angle) + (−0.208×sagittal vertical axis).Conclusions: When the patient is placed on the surgical table by rotating them at the OMA, the rotation of the surgical table can be reduced, ensuring a safe and efficient surgical procedure.